7 / 9
WWW.DDTOP.COM
6 Installation
6.1 Installation Tool
6.1.1 Wrench, flange gasket and flange bolts for process connections.
6.1.2 Level
6.2 Installation Technical Requirements
6.2.1 According to the position of the scale, the fixing bracket of the welding scale should be placed
on a vertical line with a deviation of ≤ 2° (Figure 4).
Figure 4 Installation
6.2.2 The bottom guiding mechanism and the buoy are taken into the tank from the inlet hole. By
observing the perpendicularity of the guide wire at the top, it is determined that ≤ 2°, and the
bottom guiding mechanism is welded and fixed to the bottom of the tank. (Figure 5)
Figure 5 Installation