Preface 

 

Thank you for choosing the products of Dandong Top Electronics Instrument (Group) Co., Ltd. 

 

This operation manual provides you with important information about installation, connection and 

commissioning as well as maintenance, troubleshooting and storage. Please read it carefully before 

installation and commissioning and save it as an integral part of the product near the instrument for 

reading at any time. 

 

This manual can be downloaded from www.ddtop.com. 
If you do not follow this manual, the protection provided by this instrument may be damaged. 

 

Trademarks, Copyrights and Restrictions Instructions 

Dandong Top Electronics Instrument (Group) Co., Ltd.®, Dandong Top Pump Co., Ltd.®, DDTOP® 

are registered trademarks of the company. 

 
The  performance  specifications  of  this  instrument  are  effective  from  the  date  of  release,  and  are 
subject to change without notice. Dandong Top Electronics Instrument (Group) Co., Ltd reserves the 
right to modify the products described in this manual at any time without prior notice. 

 

Quality Assurance 

Dandong Top Electronics Instrument (Group) Co., Ltd guarantees that all products will be free from 

defects  in  materials  and  manufacturing  processes  within  one  year  from  the  date  of  leaving  the 

factory. 

 
During  the  warranty  period,  if  the  product  is  returned  due  to  quality  problems,  and  the  claim  is 
determined to fall within the scope of the warranty after inspection by the manufacturer, Dandong 
Top Electronics Instrument (Group) Co., Ltd is responsible for repairing or replacing it for the buyer 
(or owner) free of charge. 
 

Dandong  Top  Electronics  Instrument  (Group)  Co.,  Ltd  is  not  responsible  for  the  costs  caused  by 

improper use of equipment, labor claims, direct or subsequent damage, and installation and use of 

equipment.  Except  for  the  special  written  warranty  certificate  for  certain  products,  Dandong  Top 

Electronics Instrument (Group) Co., Ltd does not provide any express or implied quality guarantee. 

 

Quality 

Dandong  Top  Electronics  Instrument  (Group)  Co.,  Ltd  has  passed  the  ISO9001  quality  system 

certification. The entire production process is strictly implemented in accordance with the scope of 

the quality system, providing the strongest guarantee for the quality of products and services.

 

Содержание LGNC

Страница 1: ...1 8 WWW DDTOP COM LGNC INTEGRAL ORIFICE FLOW METER Operation Manual LGNC DT JS 1029 2018 A...

Страница 2: ...rior notice Quality Assurance Dandong Top Electronics Instrument Group Co Ltd guarantees that all products will be free from defects in materials and manufacturing processes within one year from the d...

Страница 3: ...m and 10 times the pipe diameter downstream which achieves a good rectification effect and reduces uncertainty 6 4 3 High precision after the actual flow calibration of integral orifice plate flow met...

Страница 4: ...or non flammable site operating procedures 1 2 Process leaks can cause serious injury or death If the process seal is damaged the medium may leak at the connection 1 3 Failure to follow the safety in...

Страница 5: ...d before and after the flow element through the differential pressure transmitter can output and the measured fluid flow value as a square relationship between the standard signal can be converted int...

Страница 6: ...ge points 5 Outline Dimension Diagram Figure 2 The dimensions of D and L in the picture are subject to the actual product 2 Figure 2 6 Unpacking and Inspection 6 1 Precautions for Unpacking Inspection...

Страница 7: ...anges slowly 8 5 Before the fluid flows through the flow element its stream must be parallel to the axis of the pipeline and there must be no rotating flow 8 6 The standard flow element is not suitabl...

Страница 8: ...ned on Turn on power supply 2 Stop valve is not opened Open the stop valve 3 Differential pressure transmitter failure Check differential pressure transmitter Medium leakage at the flow element 1 Insu...