A P P E N D I X A
OUTPUT CONFIGURATION
TBx Jumpers are configured as per
to select an appropriate output
option.
Table 3. Output TBx Jumper Configuration
(Applies to TB1-6) Jumpers Installed
Output Option #
Type
Hybrid Type
3 5 8
1
11.8v Synchro
3-4, 5-6, 7-8, 9-10 3-4,
5-6,
7-8,
9-10
N/A
2 11.8v
Resolver
N/A
1-2,
5-6, 7-8, 9-10
7-8, 9-10
3
6.8v Resolver
N/A
1-2, 7-8, 9-10
N/A
4 2v
Resolver
N/A
N/A
N/A
5 (Note 3)
11.8v Synchro
N/A
3-4, 5-6, 7-8, 9-10
N/A
6 (Note 3)
11.8v Resolver
N/A 1-2,
5-6,
7-8,
9-10 N/A
7 (Note 3)
90v Synchro
N/A
3-4, 5-6, 7-8, 9-10
N/A
8 (Note 3)
90v Synchro
N/A
3-4, 5-6, 7-8, 9-10
N/A
Notes:
1. N/A = No jumpers installed.
2. 90v output requires a transformer.
3. Transformer coupled output configurations cannot be field reconfigured. (Output options 5, 6, 7, 8).
4. For reference type 0 & 6 when applying a 115v ref input, remove jumpers 7-8 and 9-10.