background image

PLACING & ANCHORING - ELECTRICAL     

Lift and place the cooktop in the opening.  Be careful not to
pinch the power cord or gas inlet between anything.  Anchor
the cooktop; ensure that the appliance is in place and level
(See Fig.7). 

For cabinets with side access, screw the 2 “L” shaped brackets
(supplied) into the holes provided using the #10 sheet-metal
screws as shown in Fig.7 cooktop.  Then using the 1/4 - 20
bolt and nuts (supplied), anchor as shown.

For cabinets with no side access, first fasten the brackets to
the cabinet side wall using a suitable fastener.  Then drill two
5/32” dia. holes upward into the bottom of cooktop and fas-
ten as shown in Fig 7. countertop.

POWER REQUIREMENTS:

120 VAC, 60 Hz.

7 Amp.

(Use 15 Amp. Circuit)

Always disconnect electric supply cord from the wall outlet or
service disconnect before servicing this appliance.  Observe all
governing codes and ordinances when grounding, in absence
of which, observe National Electrical Code ANSI / NFPA
No. 70-1987.

RECOMMENDED GROUNDING METHOD

This appliance is factory equipped with a power supply cord
with a three-prong grounding plug (with polarized parallel
blades).  

It must be plugged into a mating grounding, type

receptacle, connected to a correctly polarized 120 Volt circuit.

If the circuit does not have a grounding type receptacle, 

it is

the responsibility and obligation of the installer or user

to have

the existing receptacle changed to a properly grounded and
polarized receptacle in accordance with all applicable local
codes and ordinances by a qualified electrician.  In the
absence of local codes and ordinances the receptacle replace-
ment shall be in accordance with the National Electrical
Code.  

THE THIRD PRONG SHOULD NOT, UNDER ANY
CIRCUMSTANCES, BE CUT OR REMOVED (See Fig. 8).
(See Fig. 9).

Receptacle Box
Cover Plate

Three Prong
Receptacle

Three
Prong
Plug

610 fi 23

STEP 4: ELECTRICAL CONNECTIONS

Side access anchoring:

777fig09

Bottom access anchoring:

Cooktop

Countertop

STEP 3:  PLACING & ANCHORING

5

FIG. 7

FIG. 8

Содержание DCS-C-24W

Страница 1: ...Retain this manual for future reference CERTIFIED DESIGN A MERICAN A S SO CIATIO N G S A PROFESSIONAL DCS C 24W WOK COOKTOP MODEL CARE INSTALLATION MANUAL ...

Страница 2: ...I N S T A L L A T I O N I N S T R U C T I O N S USE AND CARE INSTRUCT I O N S WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance ...

Страница 3: ...ant Installation Information Tested in accordance with ANSI Z21 1 1987 Standard for Household Cooking Gas Appliances Check local building codes for the proper method of cooktop installation In the absence of local codes the cooktop should be installed in accordance with the National Fuel Code Z223 1 1984 and National Electrical Code ANSI NFPA No 70 1987 CAUTION When connecting unit to LP gas make ...

Страница 4: ...top depth See Fig 2 side view of cooktop see Figs 3 5 for alternate mounting positions 9 12 22 5 8 26 3 8 23 3 8 3 To Center Line of Gas Inlet 3 4 1 2 Cabinet face for installation with projecting control panel Cabinet face for installation with flush control panel 2 Countertop level 777fig07 Counter Sunk Screws CABINET PREPARATION 3 STEP 2 COOKTOP INSTALLATION VENT HOOD 12 Min to Combustible Mate...

Страница 5: ...er for the gas inlet and power cord clearance If a solid side cabinet wall exists on one or both sides you will need to notch the front corner of the cabinet to match the counter top notch and to allow clearance for the cooktop front See Fig 5 Wok Front Flush with cabinets Wok Front projects outward from cabinets Typical of standard depth cabinetry Minimum of 25 3 8 cabinet depth req d 777fig08 CA...

Страница 6: ...in absence of which observe National Electrical Code ANSI NFPA No 70 1987 RECOMMENDED GROUNDING METHOD This appliance is factory equipped with a power supply cord with a three prong grounding plug with polarized parallel blades It must be plugged into a mating grounding type receptacle connected to a correctly polarized 120 Volt circuit If the circuit does not have a grounding type receptacle it i...

Страница 7: ...e appliance to the power supply CAUTION Attaching the adapter ground wire to wall receptacle cover screw does not ground the appli ance unless the cover screw is grounded through house wiring If there is any doubt as to whether the wall receptacle is properly grounded the customer should have it checked by a qualified electri cian Cold water pipe must have metal continuity the electrical ground an...

Страница 8: ...Gas Code ANSI 223 1 1984 Install the 1 2 coupling to the gas inlet at the left rear cor ner of the unit Next install the 1 2 close nipple and reg ulator See Fig 11 When installing the regulator be sure to have the arrow on the regulator body pointing towards the cooktop inlet Only use sealant which is resistant to the actions of LP gases To operate push and turn the burner control knob to the lite...

Страница 9: ...yellow tips excessive noise or lifting If any of these conditions exist check that the regulator is installed with the arrow pointing towards the appliance and that it is 5 0 inches w c Nat gas and 10 0 inches for propane If this condition persists the air shutters should be adjust ed Begin by removing the valve panel using the access hole provided loosen the air shutter locking screw on the face ...

Страница 10: ... straps securing burner to channel have been removed Backguard attached if less than 12 clearance to combustibles behind unit Electrical Polarized 120 VAC 15 ampere receptacle with 15 ampere over current protection pro vided for service cord connection Gas Supply Pressure regulator shipped with unit connected to manifold and is set for 5 0 W C for natural gas and 10 0 W C for LP Manual gas shut of...

Страница 11: ...e gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier PROPANE GAS INSTALLATION Each unit is ready for use with natural gas It may be con verted for use with propane gas by a qualified service tech nician or installer Be sure the unit being installed is corre...

Страница 12: ...nless specifically recommended in this manual All servicing should be referred to a qualified technician Children should not be left alone or unattended in an area where appliances are in use They should never be allowed to sit or stand on any part of the appliance Caution Do not store items of interest to children above any of the units or at the back of them if children should climb onto an appl...

Страница 13: ...use any appliance until the gas has had time to dissipate Wait at least 5 minutes before using a gas appliance Be sure all appliance controls are turned off and they are cool before using any type of aerosol cleaner on or around any gas appliance The chemical that produces the spray ing action could in the presence of heat ignite or cause metal parts to corrode Never leave the wok unattended when ...

Страница 14: ...the metal and keeps food from sticking 5 After using the wok wash it in hot soapy water Do not use abrasives or scour Apply a light coat of vegetable oil to the inside surface with a paper towel Place the wok over a low setting for approx 15 to 30 seconds remove from heat and let cool Wipe off excess oil before storing WARNING Do not leave wok unattended while cooking NOTE It is normal for the wok...

Страница 15: ... flame or burner flutter Have the flame adjusted by a technician Foreign particles in the gas line may cause an orange flame during initial use This will disappear with use For proper lighting and efficient performance of the burn er it is necessary to keep the igniter and burner ports clean If the flame is uneven flutters makes excessive noise or lifts check to see if the burner ports are clogged...

Страница 16: ...tric spark igniter sparks The flame does not burn blue completely around both rings of the burner When cool grasp the burner and lift up so it is above the burner support guide posts towards the rear of wok The venturi tube will release from the orifice hood that is attached at the front of the wok Once the venturi tube is disconnected from the orifice hood the burner may now be lifted out Be care...

Страница 17: ...er installation such as no regulator improper hook up etc Chipping of porcelain enamel burner Service visits to Correct the installation You are responsible for providing electrical wiring gas installation and other connecting facilities Reset circuit breakers replace home fuses or establish gas supply Damage caused from accident abuse alteration misuse incorrect installation or installation not i...

Страница 18: ...ocess at DCS we reserve the right to change specifications or design without notice Litho in USA 8 97 Part No 10777 5800 Skylab Road Huntington Beach CA 92647 714 372 7000 Fax 714 372 7001 Customer Service 888 281 5698 www dcsappliances com ...