LIGHTING INSTRUCTIONS
12
MATCH LIGHTING
Hold a lit match near the burner ports, turn the control
knob counterclockwise to “HI”.
Move your hand
immediately once the burner is lit. Rotate the control
knob to the desired setting. Check for proper burner
flame characteristics and adjust the air shutters if
necessary. (Fig. 08)
Each burner is adjusted prior to shipment; however,
variations in the local gas supply may make minor
adjustments necessary.
Burner flames should be blue and stable with no yellow
tips, excessive noise, or lifting (Fig. 09). If any of these
conditions exist check that the air shutter or burner
ports are not blocked. If the flame is yellow, indicating
insufficient air, turn the air shutter counterclockwise to
allow more air into the burner. If the flame is noisy and
tends to lift away from the burner, indicating too much
air, turn the air shutter clockwise to reduce the air
opening. To access the open burner air shutter, remove
the burner grate. The locking screw is on top of the
venturi, loosen, adjust, retighten. (See Page 14, Fig. 10)
3/8"
1-1/2"
FIG.08
FIG.09