dCS 954
User Manual
Manual for Standard Software Version 1.5x
dCS
Ltd
June 2000
Manual part no: DOC136954 iss 2B1
Page 27
file 135954ma2b1.pdf available from website
Contact
dCS
on + 44 1799 531 999
email to: [email protected]
(inside the UK r 44 with 0)
web site: www.dcsltd.co.uk
BNC
-
(
BNC
Button). In PCM mode, this controls the operation of the
BNC
button.
Input
Configures the BNC input connectors as a data
input. Press the
BNC
button to select it.
RefCl
Configures the BNC word clock in (Clk In)
connector as a reference clock input. Press the
BNC
button to sync the unit to the Word clock
while taking data from one or more of the AES
inputs. The BNC LED will light, in addition to the
LED(s) for the data source. Press the
BNC
button
again to sync to the data input instead.
This mode of operation enable the unit to sync to one clock source and rapidly
switch between other synchronous sources without going through a PLL locking
sequence. It might be used, for example, in A/B comparisons or in locking to a
house sync, just taking data from AES feeds.
If the unit is already locked to SDIF or DSD, the
RefCl
option is disabled.
BNC O
-
(
BNC O
utput). In PCM mode, this sets the format of the
BNC
Out
connector
(Clk Out).
SDIF
Sends out SDIF Word Clock on the Clk Out
connector. The unit must be locked to generate an
output.
AES
Sends out AES3 coded data at TTL levels, at up to
96 kS/s on the
Clk Out
connector. This works
when the unit is locked to Single AES, SDIF or
BNC - AES input.
Panel
-
(
Panel Control
). Sets the operation of the
Phase
and
De-Emphasis
buttons.
Phase
Sets the two buttons to their standard functions.
Vol
The two buttons act as a digital volume control.
Phase
reduces the
Volume
in 0.1dB steps, while
De-Emphasis
increases the
Volume
. The change
accelerates if a button is held down. The range is
0dB to –20dB.
Phone
-
dCS
telephone number scrolls across the display.
Facs
-
dCS
fax number scrolls across the display
Part
-