Introduction

The   DC120833   is   programmed   for   an   automatic   four   stage   (Ud-I-Uo-Up)   charging 

process. It is designed for 12V, 2 to 60Ah sealed lead-acid batteries. It is also ideal for 

keeping all other lead acid battery types “topped up” and maintained. Stage “Ud” is for 

assisting with de-sulfating the battery through a pulse charge process. When battery is 

sufficiently recovered, stage “I” will give bulk current charging (0.8A or 3.3A, defined by 

user). Then, “Uo” stage follows where the current is reduced and the output voltage is 

regulated to 14.4V (14.7V is for low temperature selection (Snow symbol)). When the 

current is [automatically] reduced to 0.4A, stage ”Up” begins. At the completion of this 

stage, the battery is charged completely and the charge cycle is finished. The charger 

will enter pulse charge mode again when the battery voltage drops below 12.90V, thus 

maintaining the battery as fully charged.

For 2 to 12Ah battery, select 0.8A (Motorcycle symbol) and for 12 to 60Ah battery, select 

3.3A (Car symbol).The (Snow symbol) mode is also suitable for batteries requiring 14.7V 

Top of Charge voltage (TOC). 

Specification 

Input Voltage

100-240VAC, 50-60Hz 

Input Current

1.1A

Back current drain

1.3mA (current used from battery when not connected to power)

Charge voltage

Rating 12V, Bulk 14.4V/14.7V (14.7V for low temperature)

Charge current

0.8A (2~12Ah, Motorcycle) 3.3A (12~60Ah, Car)

Operating Temp

-20C to 50C

Cooling

Natural convection. Do not cover the charger.

Charge principle

Automatic 4 stages. Ud-I-Uo-Up 

Battery type

12V sealed lead-acid batteries. AGM, Gel, VRLA, SLA.

Battery capacity

2~60Ah

Maintenance

All 12V lead acid battery types

Maintenance Volts

Charger restarts when battery voltage drops below 12.90V

Charger  will  not  overcharge  “sealed”  lead  acid  batteries.  Although  this  charger  can  be  used on  “wet” 

batteries and is in fact ideal for maintaining them, it is not suitable for Calcium types when discharged.

How to use:

1.

Connect positive clip (red) to positive battery terminal, the black clip to negative.

2.

Connect   the  AC   cord   to   the   power   outlet.   The   red   alarm   indication   light   will 

indicate a battery which is connected in reverse polarity.

3.

Pressing the “MODE” (MD) button and stepping forward one press at a time until 

the required mode is reached.

4.

When the “charging finished” led lights up, the battery is fully charged. Leave the 

battery connected for maintenance charging. 

5.

When disconnecting charger, disconnect in reverse sequence from connecting.

The table shows the duration of Bulk step-up to about 80% state of charge.

Battery type

Ah

MODE

Time

hours

2

2-3

12

10-12

14

3-4

50

12-14

60

18-20

Mode 
select 
button

Errors!
(reversed 
connection)

De-sulfating 
process

Charging
process

Charging finished. 

Pulse maintenance

Power
on

2~12Ah 
battery 
setting

12~60Ah 
battery 
setting

Low temperature 
setting.
Also used for 14.7V 
TOC.