D
IGITAL
C
ONTROL
I
NCORPORATED
[email protected] www.DigiTrak.com 1.425.251.0559, 1.800.288.3610 US/CA
Page 2 of 2
®
SBC NiMH Battery Charging System
Battery Charger Status Indicators
LED
Charger Mode
Orange
Battery not connected.
Orange
Battery initialization and analysis (approximately 30 seconds).
Red
Fast charge (approximately 3 hours).
Green
and flashing
Orange
Top-off charge (approximately 15 minutes).
Green
Battery is charged; trickle charge will occur until battery is removed
(recommended the battery be removed within 24 hours).
Red
and
Green
alternating
Error. Contact DCI.
SE NiMH battery packs (SBP) can also be charged in
designated F Series Battery Chargers (FBC), but
operating times in different system components will vary.
Estimated Battery Operating Times
System Component
SBP
F5/Falcon F5 receiver
up to 5 hrs
SE, Falcon F1/F2 receiver
up to 6 hrs
SED/FCD remote display
up to 12 hrs
A battery pack can be recharged about 400 times before
its life is substantially reduced.
Specifications
Charger
Part number ........................................................................ SBC
Power input rating ..................................... 10
–28 VDC, 5 A max
Power output rating ................................... 19.2 VDC, 1.8 A max
Weight, without battery ...................................................0.36 kg
Battery
Part number ........................................................................ SBP
Operating temperature ............................................ -10 to 65° C
Weight .............................................................................0.48 kg
Dimensions .................................................. 5.3 x 10.4 x 7.6 cm
DCI:
T
HE
B
USINESS OF
HDD
L
OCATING