DCI LLC All Rights Reserved: For technical support call (951)-805-0314
9
F
IRE
P
IT
T
ABLE
A
SSEMBLY
I
NSTRUCTIONS
13. Connect propane tank (not
included) to propane regulator using
standard propane tank connection
process. For Natural gas units turn
on gas from emergency shut off
valve.
14. Attach (1) door panel by
aligning tabs with slots and
releasing, door hooks should fit
into slots on front panel.
15.
Make sure flow valve is off in the
lock out position, turn on propane tank,
slight push in will allow knob to turn on
gas flow then light fire pit immediately
with hand held fire source/lighter. If
you smell gas DO NOT use, turn off tank
then call a professional!
Warning: Read all instructions before
operation
1
Door Panel
Figure 13
Figure 14
Figure 15
FIRE PIT TABLE ASSEMBLY INSTRUCTIONS
Leak Test
Turn on the gas supply, ignite the burner, and test at all connections for leaks using soapy
water solution. If bubbles appear, a leak is present. Turn off the gas and tighten at all
connections. Repeat until no leaks are present. If a leak persist, turn off the gas supply and
contact the local gas company. NEVER USE A FLAME TO CHECK FOR LEAKS!!!!
Keep Vents Clear
Keep Vents Clear on all sides