Instruction Manual GH06_G GAS HEATER
dcg16.it
26
MAINTENANCE GUIDE:
Injector marking:0.60(I3B/P30 or I3+),0.54(I3B/P3);
ASD model:S.I.T 8593(aeration Dia.2.6mm for 30mbar,aeration
Dia.2.4mm for 37mbar);Benan 20340(aeration Dia.3.0mm for
30mbar,Dia2.8mm for 37mbar)
There is no flame lift,no light back,no yellow flame and no leakage on
internal gas connection after maintenance.
CONNECTING THE CYLINDER
6. Place the gas filled cylinder into the back of the heater.
7. Clip on the gas regulator to the gas cylinder,connect the regulator
to flexible tubing and the valve.
8. Turn the cylinder and the regulator on.
9. Where the regulator is not supplied or is missing please contact
your gas dealer to advise of the correct type for the gas cylinder
being used.
10. IMPORTANT TEST FOR LEAKS:
This must be carried out in a well ventilated area, free from naked
flames and any other sources of ignition. With the regulator
connected to the cylinder turn on the regulator control. Brush all
hose connections, pipe connections to the valve and gas cylinder with
a 50;50 solution of detergent and water or a leak detection spray. A
stream of bubbles forming indicates a leak. If a leak is found turn of