DCCconcepts Cobalt-SS Скачать руководство пользователя страница 2

Cobalt-SS

Installing , Connecting and Adjusting your Cobalt-SS Motors

For more information visit our Website

www.DCCconcepts.com

DCCconcepts Ltd (UK and Australia)

UK: Ph +44 (0) 1729 821 080

AU: Ph +61 (0) 8 9437 2470

A clear, visual indication helps, so here’s another  diagram with Cobalt-SS plus all of the wires & accessories connected.

We have also added additional information where a more detailed explaination will be helpful. 

Please note: We have used variants of Green, Red and Blue/Black to represent the added wires. Your wire choice is up to you!

When you wire, please read the manual then also read the print on the PCB as you insert the wires. With all the information 

also printed onto the PCB at every connection point, you should find it easy to get it all right first time!

We’ve shown only 1 set of connections: A Cobalt-SS Control Board can control 2 separate DCC addresses & several motors!

The complete range of Cobalt & Alpha 

products can be found on our website at 

www.dccconcepts.com

Cobalt-SS

Cobalt-SS: Basic wiring and features

2

2

1

1

3

3

4

4

5

5

6

6

7

7

8

8

11

11

9

9

10

10

Cobalt-SS Does not mind whether you power it with DCC 

or DC and is equally usable on layouts with either system.

Wiring is soldering-free. ALL connections are either very 

simple “Plug and Play” connections or Screw Terminals.

Each Cobalt-SS Control board has TWO control outputs 

& each output can control more than 1 Cobalt-SS motor.

Operation  can  be  via  two  momentary  switches  or  by 

DCC-Digital control and setting the address is easy to do.

Basic connection needs only 1, 2 and 3 to be used. These 

and all other Cobalt-SS connections are explained below.

Power Connection: Cobalt-SS works well with both 

DC and DCC power input. Voltage range is 12~23v.
Cobalt-SS is connected with a simple plug & socket.
DCC-Addressing is via a simple switch. Choose an 

address, move it to “Set”, act as if already changing the 

turnout at that address and then return to “Run” mode.
Momentary switch connection (Left/Com/Right).
Panel LEDs or Computer I.O. or Colour Light Signals.
Independent additional S.P.D.T. changeover switch.
Turnout FROG power switching (Left/Com/Right).
Cobalt-SS “Direction Swap” switch for reversing the 

direction of the turnout throw.
Adjustment of Cobalt-SS “Point throw” distance for 

various scales or pointwork types.
Indicator LEDs to guide your adjustment of the “Point 

throw distance. (“Small-Medium-Large-Extra Large”) 
The  Reset  Buttons  re-centre  Cobalt-SS.  It  returns 

throw settings to factory Default. Hold for 3 seconds.

1

2
3

4
5
6
7
8

9

10

11

       Pushbutton switches

      (or our Cobalt-S Levers). 

This gives you DCC-Digital & 

manual point control too. 

Power IN

from the DCC track 

power bus OR the 

regulated DC Power 

Supply if you do not 

use DCC!

Power Link:

If you have several 

Cobalt-SS control 

boards, you can just 

“Daisy-Chain” them 

together with these 

terminals.

       The Reset button.

Just hold it down for 

3 seconds. Cobalt-SS 

will  then  return  to  it’s        

ex-factory settings!

        

Panel LEDs, computer IO   

      indication or  2-light signals!

      

The  easy  to  understand  “Set-Run 

Switch” for setting the address. See below 

for a step by step instruction

       A spare SPDT switch 

can do many things.

Here we have connected it to 

two isolated sections ahead of the

Heel of the point and wired it so that if 

the point is not set for the train to cross

safely, power to that section will be turned off. 

This will prevent accidental derailments and the

inevitable short-circuits that will otherwise occur!

     

Cobalt-SS has “Frog” polarity switches built 

in too so there is no need for you to add anything 

else. There is no complicated wiring so electrofrog 

or “Live Frog” points are now much easier to use!

       Connecting the Cobalt-SS is easy!

Just plug it into the socket provided! Each 

output CAN control more than one!

    

To “Swap over” the Cobalt-SS throw 

direction, just change this switch.

          To adjust the 

throw, adjust with 

a small cross-type 

screwdriver. 

        

These indicator 

LEDs show you the 

distance you set.

 

1

11

9

1

3

4

5    

6

7

2

2

8

10

Setting the DCC Address of your Cobalt-SS Motor:

Cobalt-SS

Teaching your Cobalt-SS Motor it’s new address and adjusting the throw distance

Adjusting the throw distance of a Cobalt-SS Motor:

There  are  NO  Complex  DCC-digital 

commands or CVs to remember. 

Please use these instructions, not the 

accessory  decoder  instructions  that 

are supplied with your DCC system.

SET             RUN 

Please note that if you have a screen-based system such as the 

Roco Z21 or ESU ECoS you will need to create a track diagram 

or set up an on-screen turnout before you can set an Address.

(1) Connect your Cobalt-SS to the DCC track power bus 

       or your dedicated DCC Accessory Power Bus.

(2) Decide which number you wish Cobalt-SS to use and

       then move the Set-Run switch to the “Set” position.

(3)  Follow your DCC system instructions for changing a 

       point or turnout using the number that you chose. 

       (We repeat this procedure twice just to be sure)

(4) Return the Set-Run switch to the “Run” position.

(5) Repeat 3 and Cobalt-SS will respond to that address.

All you will need to do is watch this set  

         of six LEDs marked S - M - L - XL

         to clearly indicate the set position.

         As you GENTLY adjust the position 

of this with a fine “

+

” type screwdriver! 

We chose the S - M - L - XL as it is a common designation on 

many things - indicating increase or change in size. You’ll find that 

they correspond approximately to Z, N, OO/HO and O scale.

(1) Install your Cobalt-SS and test your installation leaving 

       the settings at the factory default position.

(2) If the blade does not move fully either way, adjust the 

       installation to improve centering then re-test it.

(3) If the blade moves across well before the motor stops,

       reduce the throw by turning the adjuster anti-clockwise. 

(4) If the blade does not move fully or has weak pressure, 

       increase the throw by turning the adjuster clockwise.

(5) To go back to a default throw, hold the “Re-Set” down.

Created by

DCCconcepts

 MADE

in

CHINA

Содержание Cobalt-SS

Страница 1: ... us first Installing your DCCconcepts Cobalt SS The Basics Please read these instructions first then keep them close at hand Take your time with the first few installations Work one step at a time and check as you go Installation is quite simple all screws and fittings are supplied and the connection between Cobalt SS and its Control board is a simple plug and socket so it is easy to do and the wh...

Страница 2: ...etbutton Just hold it down for 3 seconds Cobalt SS will then return to it s ex factory settings Panel LEDs computer IO indication or 2 light signals The easy to understand Set Run Switch for setting the address See below for a step by step instruction Aspare SPDT switch can do many things Here we have connected it to two isolated sections ahead of the Heel of the point and wired it so that if the ...

Страница 3: ...n tube Phosphor bronze wire some cranks and a selection of screws and linkages Created by DCCconcepts MADE in CHINA Cobalt SS Loops Crossovers Special Wiring Connect more than one DCCconcepts Cobalt SS motors to any Control Board output All our examples use live or Electrofrog pointwork For best and most reliable layout performance we recommend you follow the instructions on our website Search for...

Страница 4: ...until it just touches the plastic of the Cobalt SS case 4 Using firm but gentle finger pressure on the Wire end of your Cobalt SS motor to make quite sure that the point blade is held firmly against its adjacent stock rail then tighten each screw a just little more to fix it in place 5 Insert one of the black screws into each slot and tighten until it just touches the plastic of the Cobalt SS case...

Отзывы: