4" (10 cm) DOT MATRIX LARGE DISPLAY
with 1~4 ALARMS / ANALOG OUTPUT / RS-485
Descriptions
Display
Default
MANUAL
FRONT PANEL & KEY FUNCTIONS
D
Please understand key indicators & functions at the first operation.
Descriptions
Symbol
Key Name
System Setting Group Procedures
Decimal Point
Setting (dP)
EX: if the value shows "0.00" that means the decimal point is 2 digits.
to select decimal point (0, 1, 2, 3, 4).
Press
Customers
specify
Customers
specify
Customers
specify
Display Low Scale
Setting (dSH)
Setting (dSL)
Display Hi Scale
EX: If the input signal is 4~20mA; 4mA is shown display 0.00,
this parameter must be set for 000.00.
to modify display low scale for the input signal zero value.
Press
to modify display high scale for the input signal span value.
EX: If the input signal is 4~20mA; 20mA is shown display 100.00,
this parameter must be set for 100.00.
Press
Display Average
Setting (AvG)
PS: Please use this function for stable display value
when input signal is unstable.
to modify display average (1~99).
Press
Display Low Cut
Setting (LCU)
to modify display low cut to 0 (0~99).
Press
Pass Code
Setting (Cod)
PS: Please don't forget the new pass code after modification.
to modify pass code (0~19999).
Press
Key Lock
Setting (LoC)
PS: no (unlock) ,YES ("ENT" unlock , others lock).
only can view the parameters, but cannot modify any values.
to lock the keys, using key lock function
Press
Display Over value
Setting (dov)
Press
to modify display overvalue setting (0~9999).
Setting (id)
Identification
Press
to modify identification (00~99).
PS: If the ID is 00; Meter can received any Infrared Control.
Pass code is correct that will enter to parameter groups.
Parameter Group Setting Procedures
Pass code is wrong that will back to measuring status.
PROGRAMMING MODE OPERATING PROCEDURES
RS485 Settin g Group
System Setting Group
Alarm Settin g Group
A/O Setting Group
Descriptions
Display
Default
Present value for measurement
Pass Code
(P.Cod)
to enter pass code.
Mea suring Status
Press
Press
ENT
P.Code Corre ct
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Power On
Press
Press
Press
Press
0000
Press
Press
ENT
Input/Output Adjustment
1. In the measuring status, press this key can enter to parameter pages.
2. In the parameter setting, press this key can save the value & go to
next parameter.
1. In the parameter setting , press this key can move the cursor left.
1. In the parameter setting, press this key can increase the digits.
1. In the parameter setting , press this key can decrease the digits.
1. In the measuring status, press this key can enter to ID confirmed page.
2. In the parameter setting, press this key can back to the measuring page.
Enter Key &
Save Key
Down Key
Shift Key
Up Key
ID Confirmed Key
Down Key
Enter Key &
Save Key
ID Confirmed Key
Reset Key
Up Key
Shift Key
Code Switching Key
ID Display Key
Display Sel ection
Setting (diS)
Press
to modify display selection (DIS, MAX, HD)
PS: DIS: Current Display; MAX; Max. Hold; HD: Hold Data
Display Filter
Setting (FiL)
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
ENT
Press
to select root square setting (NO or YES)
Root Square
Setting (Sqr)
Press
to modify display filter setting (0, 1, 2, 5).
Input Holding Band
Setting (Hb)
Press
to modify input hold band setting.
Input Holding Time
Setting (Hdt)
Press
to modify input holding time setting (0~99 sec)
Zero Band
Setting (Zb)
Press
to modify zero band setting.
Zero Trac king Time
Setting (Zd t)
Press
to modify zero tracking time setting (0~99 sec)