7
3.
INSTALLATION
3.1
Unpacking
Remove the unit from the shipping container and examine it carefully
for external damage. If shipping damage is apparent, notify the
shipper immediately.
The following accessories are included with each unit:
•
external power supply
•
manual
•
warranty, maintenance contract and repair information
•
Modem to Composite cable (black) for connecting the unit to
an external DSU/CSU
•
Network Management Port cable (green) for connecting the
network management port to an asynchronous terminal or PC
for configuration
•
If your unit has the optional built-in DSU/CSU, a cable is
included for connection to the phone line.
3.2
Setup
The frame relay options for the BPF-BU can be configured using the
Frame Relay (FR) command from the network management port.
The configurable parameters are:
Management (Type) - Auto, LMI, Annex D or None
Poll Interval - (5-30 sec)
Full Status Interval - (1-255 polls)
3.2.1
Management Type
When set to AUTO, the BPF-BU will automatically determine the
correct management type for your network.
3.2.2
DLCI
The BPF-BU will automatically get the proper DLCI from the
network and map that DLCI to RTU port 1. If other RTU ports are
used, they must be mapped using the CM command. (See paragraph
5.4.6)