Broadcast Polling

FRAD with Backup

TABLE OF CONTENTS

SECTION 1 - DESCRIPTION .......................................................................... 2

SECTION 2 - SPECIFICATIONS .................................................................... 5

SECTION 3 - INSTALLATION ........................................................................ 7

SECTION 4 - CONTROLS AND INDICATORS ..........................................11

SECTION 5 - NETWORK MANAGEMENT PORT .....................................14

SECTION 6 - INTERFACE SIGNALS AND CABLING.............................21

SECTION 7 - TROUBLESHOOTING ...........................................................26

SECTION 8 - WARRANTY..............................................................................28

Data Comm for Business, Inc.
PO Box 6329
Champaign, IL 61826-6329

April 20, 2009

(217) 897-6600

Firmware Version:  2.1

www.dcbnet.com

Содержание BROADCAST POLLING FRAD BPF-2 BU

Страница 1: ...TION 3 INSTALLATION 7 SECTION 4 CONTROLS AND INDICATORS 11 SECTION 5 NETWORK MANAGEMENT PORT 14 SECTION 6 INTERFACE SIGNALS AND CABLING 21 SECTION 7 TROUBLESHOOTING 26 SECTION 8 WARRANTY 28 Data Comm...

Страница 2: ...0 seconds the remote BPF BU begins the backup process The BPF BU first attempts a connection through the Leased Line port if port RTS is asserted If RTS is not asserted the BPF BU tries the Dialup por...

Страница 3: ...wired to the ASU RTS input and the path is opened between the host computer and the remote device served by that modem To make the host modem behave properly the ASU sends out a command string This co...

Страница 4: ...LINE MODEM PORT 1 POWER ACTIVITY ERROR READY SETUPLOOPBACK LOOPBACK SETUP RESET DCB Switches DSU Telco Primary BACKUP RTU Power NMP Network Leased Dial 2 1 RESET BROADCAST POLLING FRAD OPTION MODEM RE...

Страница 5: ...management port control with an asynchronous terminal Data Format 10 bits character 1 start 1 stop 8 data including parity Interface CCITT V 24 RS 232D implemented in RJ 45 8 position connectors EIA...

Страница 6: ...Tools Monitor Port Tx Monitor Port Rx Monitor Network Status NMP Parity Ping DLCI Reset BPF Type Repeat Last Command Disconnect NMP 2 2 Environmental Operation 40 to 70 C 10 to 95 relative humidity S...

Страница 7: ...PC for configuration If your unit has the optional built in DSU CSU a cable is included for connection to the phone line 3 2 Setup The frame relay options for the BPF BU can be configured using the Fr...

Страница 8: ...o Composite cable supplied Connect the BPF BU to power The Power and Modem Ready indicators on the front panel of the BPF BU should be ON indicating the on line condition See Section 4 This may take u...

Страница 9: ...es on the SS status screen If the keep alive and full status messages are sent and received in equal numbers as shown on the SS screen the frame relay circuit should be up and operational This is not...

Страница 10: ...t port or perform the following steps using the front panel switches 1 Depress and hold the PORT 1 SETUP switch while depressing the RESET switch 2 Be sure to continue to hold the Port 1 Setup switch...

Страница 11: ...e reset of the BPF BU 4 1 2 Optional Built In DSU Switches The DSU switches are located at the rear of the unit Switch functions are shown in the following table Switch Down Up 1 56K 64K optional 2 Sl...

Страница 12: ...gh from the BPF BU No RTS from the BPF BU CTS Follows RTS CTS signal to the BPF BU DCD ON OFF Normal condition No carrier signal received from the far end TEST ON Flashing Unit is in loopback DIP swit...

Страница 13: ...LOW FLASHING 2 ON OFF The Leased Line Backup port is active SLOW FLASHING 3 ON OFF The Dial Backup port is active OFF Data Carrier Detect is not present from the composite DSU CSU indicating a problem...

Страница 14: ...on the front panel performs this function See paragraph 4 1 1 for information 5 2 2 Dedicated Terminal or PC The NMP functions are also available through a port on the rear of the unit labeled Network...

Страница 15: ...ounters Zero AC Z RAC RZ 5 4 14 Test Tools TT 5 4 18 Type TY RTY 5 4 15 Repeat Last Command 5 4 16 Disconnect NMP BYE 5 4 17 This Help screen shows the choice of commands available The commands allow...

Страница 16: ...ng error status keep alive frames sent and received full status frames sent and received and a list of all DLCIs assigned to the local frame relay node The Z command Z RZ is used to zero the counters...

Страница 17: ...t press Enter to leave the setting unchanged 5 4 9 Configure Internal DSU 6 14 Port Units Only The Configure Internal DSU CN command is only available when the optional internal DSU CSU is installed T...

Страница 18: ...sented in terms of blocks of information sent and received by the network and each data port Error counts are also shown A range of ports may be included with this command to reduce the number of port...

Страница 19: ...onitor Port TX or RX The Monitor Port TX MT command monitors data transmitted from the selected port to the corresponding port of the remote BPF BU The Monitor Port RX MR command monitors data receive...

Страница 20: ...FULL STATUS response WARNING Monitor is running Stop monitor Y N Y 00 00 00 09 Monitor stopped 5 4 21 NMP Parity The NMP Parity command P sets the parity for the network management port To change typ...

Страница 21: ...FACE SIGNALS AND CABLING 6 1 Connector Location and Pin Reference BPF BU Rear Panel and RJ 45 Jacks RJ 45 Plug Positions 1 2 3 4 5 6 7 8 Switches DSU Telco Primary BACKUP RTU Power NMP Network Leased...

Страница 22: ...t 1 Data Set Ready OUT 2 Data Carrier Detect OUT 3 Busy IN 4 Signal Ground 5 Receive Data OUT 6 Transmit Data IN 7 Clear to Send OUT 8 Request to Send IN 6 2 3 Network Management Port RJ 45 Pin Signal...

Страница 23: ...odem to composite cable is included with each BPF BU The configuration is as follows BPF BU Modem RJ 45 DB 25P 6 3 2 RTU Ports To a DTE device BPF BU Device RJ 45 DB 25 or other flow control output pi...

Страница 24: ...ontrol output pin or other flow control input pin To a PC Com Port BPF BU Computer RJ 45 DB 25S DE 9S 6 3 3 Dial Backup Port to ASYNC Modem 9802018 1 2 3 4 5 6 7 8 20 5 7 2 3 4 8 1 2 3 4 5 6 7 8 6 or...

Страница 25: ...o a TERMINAL NMP Terminal RJ 45 DB 25P To a PC using terminal emulation NMP Computer RJ 45 DE 9S DB 25S To a dial up MODEM for remote access NMP Modem RJ 45 DB 25P 20 7 3 2 5 6 8 4 3 4 5 6 7 8 4 or 20...

Страница 26: ...test functions and record your results 7 2 Loopback Tests It is best to begin loopback testing at the remote terminal and work toward the host If all the loopbacks are successful the data communicati...

Страница 27: ...4 Installation Troubleshooting BPF BUs Before trying terminals make sure the BPF BUs are able to see each other Use the RTY command to verify a response from the remote BPF BU If you get a correct res...

Страница 28: ...l damages etc DCB liability shall not exceed the original purchase price All equipment returned for repair must be accompanied by a Returned Material Authorization RMA number To receive an RMA number...