DBI SALA ULTRA-LOK 3504550C Скачать руководство пользователя страница 4

4

Figure 3  –  Fall Clearance and Swing Fall

A

!

 

WARNING

B

H

V

FC

FC = Minimum Fall Clearance

FC

ft (m)

H - Horizontal Distance from Anchorage Point

(0.0)

(0.6)

(1.2)

(1.8)

(2.4)

10 

(3.0)

12 

(3.7)

14 

(4.3)

16 

(4.9)

18 

(5.5)

20 

(6.1)

V - Vertical Distance from Anchorage Point

(0.0)

(2)

(2.6)

8

8

8

8

8

8

8

8

8

10

(3)

(2)

6.2 

(2.1)

6.8 

(2.3)

7.7 

(2.6)

8.8 

(2.9)

8

8

8

8

8

8

20 

(6.1)

(2)

6.1 

(2)

6.4 

(2.1)

6.9 

(2.3)

7.5 

(2.5)

8.4 

(2.7)

9.3 

(3)

8

8

8

8

30 

(9.1)

(2)

6.1 

(2.1)

6.3 

(2.1)

6.6 

(2.2)

(2.3)

7.6 

(2.5)

8.3 

(2.7)

9.1 

(3)

8

8

8

40 

(12.2)

(2)

(2)

6.2 

(2.1)

6.4 

(2.1)

6.8 

(2.2)

7.2 

(2.4)

7.8 

(2.5)

8.4 

(2.7)

9.1 

(2.9)

9.9 

(3.2)

8

50 

(15.2)

(2)

(2)

6.2 

(2.1)

6.4 

(2.2)

6.6 

(2.2)

(2.3)

7.4 

(2.5)

7.9 

(2.6)

8.5 

(2.8)

9.1 

(3)

9.9 

(3.2)

60 

(18.3)

(2)

(2)

6.1 

(2)

6.3 

(2.1)

6.5 

(2.1)

6.8 

(2.2)

7.2 

(2.4)

7.6 

(2.5)

8.1 

(2.6)

8.6 

(2.8)

9.2 

(3)

70 

(21.3)

(2)

(2)

6.1 

(2.1)

6.3 

(2.1)

6.5 

(2.2)

6.7 

(2.2)

(2.3)

7.4 

(2.5)

7.8 

(2.6)

8.3 

(2.7)

8.8 

(2.9)

80 

(24.4)

(2)

(2)

6.1 

(2)

6.2 

(2)

6.4 

(2.1)

6.6 

(2.2)

6.9 

(2.3)

7.2 

(2.3)

7.6 

(2.5)

(2.6)

8.5 

(2.7)

90 

(27.4)

(2)

(2)

6.1 

(2.1)

6.2 

(2.1)

6.4 

(2.2)

6.6 

(2.2)

6.8 

(2.3)

7.1 

(2.4)

7.4 

(2.5)

7.8 

(2.6)

8.2 

(2.7)

100 

(30.5)

(2)

(2)

6.1 

(2)

6.2 

(2)

6.3 

(2.1)

6.5 

(2.1)

6.7 

(2.2)

(2.3)

7.3 

(2.4)

7.6 

(2.5)

(2.6)

110 

(33.5)

(2)

(2)

6.1 

(2.1)

6.2 

(2.1)

6.3 

(2.1)

6.5 

(2.2)

6.7 

(2.2)

6.9 

(2.3)

7.2 

(2.4)

7.5 

(2.5)

7.8 

(2.6)

120 

(36.6)

(2)

(2)

6.1 

(2)

6.1 

(2)

6.3 

(2.1)

6.4 

(2.1)

6.6 

(2.2)

6.8 

(2.2)

7.1 

(2.3)

7.3 

(2.4)

7.7 

(2.5)

130 

(39.6)

(2)

(2)

6.1 

(2.1)

6.1 

(2.1)

6.2 

(2.1)

6.4 

(2.1)

6.6 

(2.2)

6.8 

(2.3)

(2.3)

7.2 

(2.4)

7.5 

(2.5)

140 

(42.7)

(2)

(2)

6.1 

(2)

6.1 

(2)

6.2 

(2)

6.4 

(2.1)

6.5 

(2.1)

6.7 

(2.2)

6.9 

(2.2)

7.2 

(2.3)

7.4 

(2.4)

150 

(45.7)

(2)

(2)

6.1 

(2.1)

6.1 

(2.1)

6.2 

(2.1)

6.3 

(2.1)

6.5 

(2.2)

6.7 

(2.2)

6.9 

(2.3)

7.1 

(2.4)

7.3 

(2.4)

160 

(48.8)

(2)

(2)

(2)

6.1 

(2)

6.2 

(2)

6.3 

(2.1)

6.4 

(2.1)

6.6 

(2.2)

6.8 

(2.2)

(2.3)

7.2 

(2.3)

170 

(51.8)

(2)

(2)

(2)

6.1 

(2)

6.2 

(2.1)

6.3 

(2.1)

6.4 

(2.1)

6.6 

(2.2)

6.8 

(2.3)

(2.3)

7.2 

(2.4)

180 

(54.9)

(2)

(2)

(2)

6.1 

(2)

6.2 

(2)

6.3 

(2.1)

6.4 

(2.1)

6.5 

(2.1)

6.7 

(2.2)

6.9 

(2.2)

7.1 

(2.3)

190 

(57.9)

(2)

(2)

(2)

6.1 

(2)

6.2 

(2.1)

6.3 

(2.1)

6.4 

(2.1)

6.5 

(2.2)

6.7 

(2.2)

6.9 

(2.3)

(2.3)

 

8

Added Swing Fall Length is not within the recommended work zone.

NOTE:

 Fall Clearance (FC) values in the above table assume a fall from a standing position. If the 

worker is kneeling or crouching near an edge when a fall occurs, an additional 3 ft (1 m) of Fall 

Clearance is needed.

2.0 USE

2.1 RESCUE 

PLAN:

 When using this equipment, the employer must have a rescue plan and the means at hand 

to implement it and communicate that plan to users, authorized persons, and rescuers.

2.2 INSPECTION 

FREQUENCY:

 Table 1 indicates inspection frequency. SRLs shall be inspected by the 

authorized person

1

 or rescuer

2

 before each use (See Table 2). Results of the Competent Person inspection 

should be recorded in the 

“Inspection and Maintenance Log” 

at the back of these instructions or recorded with 

the i-Safe™ system (see Section 5). CSA Z259.2.2 Type 2 and Type 3 SRLs, must be submitted to a Capital 

Safety Authorized Service Agent within 2 years of the date of manufacture for inspection and maintenance, 

and annually thereafter. The Authorized Service Agent will record their findings and label the product with the 

next annual service date. Results of the Authorized Service or Competent Person inspection should be recorded 

in the 

“Inspection and Maintenance Log” 

at the back of these instructions or recorded with the i-Safe™ system 

(see Section 5).

2.3 NORMAL 

OPERATIONS:

 Normal operation will allow the lifeline to extend and retract with no hesitation 

or slack as the worker moves at normal speeds. If a fall occurs, a speed sensing brake system will activate, 

stopping the fall and absorbing much of the energy created. Sudden or quick movements should be avoided 

during normal work operation, as this may cause the SRL to lock up. For falls which occur near the end of 

the lifeline travel, a reserve lifeline system or Energy Absorber has been incorporated to reduce the fall 

arrest forces. If the SRL has been subjected to fall arrest forces: remove it from service, mark or tag as 

“UNUSABLE”, inspect and service as instructed in Sections 5 and 6. 

1 Authorized 

Person:

 A person assigned by the employer to perform duties at a location where the person will be exposed to a fall hazard.

2 Rescuer:

 Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.

Содержание ULTRA-LOK 3504550C

Страница 1: ...in 26 7 cm 7 2 in 18 29 cm 1 In addition to the Working Range there is a 2 ft 61 cm Emergency Reserve Maximum Arrest Force 900 lbs 4 kN Average Arrest Force 900 lbs 4 Kn Maximum Arrest Distance 54 in...

Страница 2: ...s Instruction Manual are drum wound Wire Rope Lifelines C which retract into a thermoplastic or aluminum Housing B They hang from overhead anchorage by a Carabiner attached through the Swivel Eye A on...

Страница 3: ...d or cramped spaces may not allow the body to reach sufficient speed to cause the SRL to lock if a fall occurs Working on slowly shifting material such as sand or grain may not allow enough speed buil...

Страница 4: ...rom a standing position If the worker is kneeling or crouching near an edge when a fall occurs an additional 3 ft 1 m of Fall Clearance is needed 2 0 USE 2 1 RESCUE PLAN When using this equipment the...

Страница 5: ...NS Snap hooks and carabiners used with this equipment must be self locking Ensure all connections are compatible in size shape and strength Do not use equipment that is not compatible Ensure all conne...

Страница 6: ...ipod and the Lifeline is routed through a Pulley System on the Head of the Tripod 1 Secure the Quick Mount Bracket on the leg of the Tripod Assemble the Quick Mount Bracket around the Upper Tube of th...

Страница 7: ...Pregnant women or minors must not use DBI SALA Self Retracting Lanyards 4 1 BEFORE EACH USE Before each use of this fall protection equipment carefully inspect it to assure it is in good working cond...

Страница 8: ...o a lower level when a fall occurs When working with an SRL always allow the lifeline to recoil back into the device under control A tag line may be required to extend or retract the lifeline during c...

Страница 9: ...rrest Mode Extension Pole Release Tool Insert the Extension Pole Release Tool from any direction so the ends of the Release Forks surround the base of the RSQ Engagement Knob below the Knurled Ridge a...

Страница 10: ...r Rotate the Crank Arm counterclockwise After fall arrest crank the Crank Arm clockwise slightly first to release the Fall Arrest Brake then crank the Crank Arm counterclockwise Figure 11 Retrieval Op...

Страница 11: ...service and sent to an authorized service center for repair IMPORTANT Extreme working conditions harsh environments prolonged use etc may require increasing the frequency of inspections 5 3 UNSAFE OR...

Страница 12: ...s must be present on the Ultra Lok SRL Labels must be replaced if they are not fully legible Contact Capital Safety for replacement labels E H I J A B E G 9502789 Rev B F G C D F H I J A B C D E G B A...

Страница 13: ...one strand in one lay A lay of wire rope is the length of wire rope it takes for a strand the larger groups of wires to complete one revolution or twist along the rope Replace the wire rope assembly...

Страница 14: ...SPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By App...

Страница 15: ...SPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By App...

Страница 16: ...DES AND DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND SHALL NOT BE LIABLE FOR INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY NATURE INCLUDING WITHOUT...