DBI SALA FlexiGuard 8517714 Скачать руководство пользователя страница 5

5

2.0   SYSTEM REQUIREMENTS

2.1  COMPATIBILITY OF COMPONENTS:

 DBI-SALA equipment is designed for use 

with DBI-SALA approved components and subsystems only. Substitutions or 

replacements made with non-approved components or subsystems may jeopardize 

compatibility of equipment and may effect the safety and reliability of the 

complete system.

2.2  COMPATIBILITY OF CONNECTORS:

 Connectors are considered to be compatible 

with connecting elements when they have been designed to work together in 

such a way that their sizes and shapes do not cause their gate mechanisms to 

inadvertently open regardless of how they become oriented. Contact DBI-SALA if 

you have any questions about compatibility. Connectors (hooks, carabiners, and 

D-rings) must be capable of supporting at least 5,000 lbs. (22.2kN). Connectors 

must be compatible with the anchorage or other system components.  

Do not use equipment that is not compatible. Non-compatible connectors may 

unintentionally disengage (see Figure 2). Connectors must be compatible in size, 

shape, and strength. Self-locking snap hooks and carabiners are required by CE, 

ANSI Z359.1 and OSHA.

Figure 2 - Unintentional Disengagement (Roll Out)

If the connecting element that a snap hook (shown) or carabiner attaches to is 

undersized or irregular in shape, a situation could occur where the connecting 

element applies a force to the gate of the snap hook or carabiner. This force may 

cause the gate (of either a self-locking or a non-locking snap hook) to open, allowing 

the snap hook or carabiner to disengage from the connecting point.

Small ring or other

non-compatibly

shaped element

1. Force is applied to 

the snap hook.

2. The gate presses against 

the connecting ring.

3. The gate opens allowing 

the snap hook to slip off.

2.3 CONNECTIONS: 

Only use self-locking snap hooks and carabiners with this 

equipment. Only use connectors that are suitable to each application. Ensure all 

connections are compatible in size, shape and strength. Do not use equipment 

that is not compatible. Ensure all connectors are fully closed and locked.

 

DBI-SALA connectors (snap hooks and carabiners) are designed to be used only 

as specified in each product’s user instructions. See Figure 3 for inappropriate 

connections. DBI-SALA snap hooks and carabiners should not be connected:

A. 

To a D-ring to which another connector is attached.

B.

 In a manner that would result in a load on the gate.

Содержание FlexiGuard 8517714

Страница 1: ...tand these instructions before assembling or using this equipment The user must follow the manufacturer s instructions for each component of the system Manufacturer s instructions must be followed for...

Страница 2: ......

Страница 3: ...ivel Wheel 3 Fixed Wheel 4 Outriggers and Jacks 5 Winch Post 6 Lifting Kit 7 Platform 8 Handrail 2 9 Overhead Anchor Point Post 10 Ladder Support Tubes 11 Davit 12 Operators Setup and Use Decal Plate...

Страница 4: ...g or metal cutting acid or caustic chemicals corrosive environments such as exposure to seawater high voltage power lines explosive or toxic gases moving machinery or sharp edges Contact DBI SALA if y...

Страница 5: ...by CE ANSI Z359 1 and OSHA Figure 2 Unintentional Disengagement Roll Out If the connecting element that a snap hook shown or carabiner attaches to is undersized or irregular in shape a situation could...

Страница 6: ...d Figure 3 Inappropriate Connections 3 0 OPERATION AND USE WARNING Consult DBI SALA when using this equipment in combination with components or subsystems other than those described in this manual Som...

Страница 7: ...y harness as the body support component PFAS s that incorporate full body harnesses must maintain fall arrest forces below 1 350 lbs 6 0 kN and arrest the fall within 42 in 1 1 m Body belts unless inc...

Страница 8: ...10 5 6 6 7 2 Outside Jacks Inner Jacks Winch Handle Locking Pin 6 in 12 in 153mm 305mm 6 in 12 in 153mm 305mm 3 5 PROCEDURE FOR USE OF THE LADDER SYSTEM Step 1 Move the unit 1 3 feet 0 3 1m away from...

Страница 9: ...Locking Pin into the ladder locking mechanism tube to the first closest hole to prevent accidental ladder movement Step 5 Push the unit to position the platform 6 in to 12 in 150 300 mm away from the...

Страница 10: ...in connected to more than one SRL while working Step 10 A maximum of two operators can be attached to the unit using the individual davits No more than one person can be attached to a davit at any tim...

Страница 11: ...the function of the Ladder FAS However if there are major dents or any other structural damage the unit should be removed from service and returned to the manufacturer for service D Corrosion Check a...

Страница 12: ...hat includes all listed items above becomes damaged contact DBI SALA for parts and or service B SRL and other Accessory Inspection Refer to the manufacturer s operator s manual or instructional materi...

Страница 13: ...arrest positioning restraint or rescue systems that a qualified person certifies to be capable of supporting the potential fall forces that could be encountered during a fall or that meet the criteri...

Страница 14: ...14...

Страница 15: ...ON DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved...

Страница 16: ...e 65 65587758 Fax 65 65587058 inquiry capitalsafety com Shanghai Rm 1406 China Venturetech Plaza 819 Nan Jing Xi Rd Shanghai 200041 P R China Phone 86 21 62539050 Fax 86 21 62539060 inquiry capitalsaf...