Mozart series calibrating procedure
18 /19
g)
On the front panel, adjust the RT1 trimmer up to see the “ALARM” led turns ON near
the display. The FWD power decreases to 0 and will try to increase automatically.
Fig. 23 – Control board RT1 adjust
NOTE: After 5 attempts to increase the FWD power, the amplifier will go in shutdown state.
The ALARM led near the button will turn ON and the RF ON led will be turned OFF. Press
RESET ALARM button to restore the normal function state of the amplifier.
Fig. 24 – Shutdown state LED turns ON
h)
Switch off the amplifier and connect the 50ohm load to the output of the amplifier.
Alarm led
turns on
RF ON/OFF
led turns off
Reset Alarm
Button