background image

13

FOR YOUR SAFETY

 READ BEFORE OPERATING

DAYVA PREMIERE OUTDOOR HEATER

Important safety instructions which if not followed could endanger the personal safety
and/or property of yourself and others.  Read and follow all instructions before attempting
to operate your Dayva Premier Outdoor Heater.
The minimum inlet gas supply pressure for the purpose of input adjustment
pressure:
LP (Propane) Gas 11.2 inches w.c.
Natural Gas 10.0 inches w.c.
The maximum inlet gas supply pressure for the purpose of input adjustment
pressure:
LP (Propane) Gas 1/2 PSI
Natural Gas 1/2 PSI
The required manifold pressure in inches of water column:
LP ( Propane) Gas 10.0 w.c.
Natural Gas 7.0 inches w.c.
WARNING:
Certain materials or items when stored under the heater, will be subjected to radiant heat
and could be seriously damaged.

Lighting, shutdown and control operations:
After fully assembling your Dayva  heater, turn on main gas supply and carefully recheck
all fittings for leakage using soap/water solution (see page 10).
If leak is discovered, turn off gas immediately. Repair seal on fitting with standard
pipe seal compound certified by a regulatory agency resistant to LP Gas.
A. Make certain main gas supply shut-off valve is in the “ON” position.
B. Push and turn gas control dial to “OFF” Position.
C. Wait sufficient length time to allow gas which may have accumulated to escape.
     (at least 5 minutes)
D. Push and turn Gas Control Dial to “ON” position.  Depress and hold dial in while
pushing red igniter button several times until pilot lights.
E. Allow burner to burn approximately 30 seconds before releasing dial.  If pilot does not
remain burning when dial is released, repeat operation allowing longer period before
releasing dial.  Wait a sufficient length of time (at least 5 minutes) to allow gas which may
have accumulated to escape.   Repeat lighting instructions.  If burner still will not light see
“TROUBLE SHOOTING”, (pages 16-17).

Содержание HS041-2

Страница 1: ...for the outdoor market Dayva prides itself in delivering quality products at reasonable prices for almost 30 years Thank you for choosing Dayva Manufactured Exclusively for Dayva International 7441 V...

Страница 2: ...SIGNED FOR OUTDOOR USE ONLY WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE READ THE ASSEMBLY INSTALLATION OPERATING AND MAINTENANCE INST...

Страница 3: ...nd the heater is equal to 40 000 BTU s after burning for five minutes The Dayva Premiere Outdoor Heater features an adjustable control valve allowing for a desired heat output Whether a cozy dinner on...

Страница 4: ...s for the heater and be sure to leak check all connections each time the cylinder is connected Always use a solution of soap and water NEVER USE AN OPEN FLAME Always turn off the gas supply to the hea...

Страница 5: ...lt in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control s...

Страница 6: ...assemble or test your heater as described have a qualified professional do it for you FOR TESTING INSTRUCTIONS SEE PAGE 11 DAYVA PREMIERE OUTDOOR HEATER MODEL HS041 2 Tools Required Phillips screwdri...

Страница 7: ...BLY PARTS SUPPLIED 50 10 32 x 1 2 Screws 50 Lock Washers 16 10 32 Nuts Tank safety strap and buckle Igniter with hex nut Regulator Instructions HOOD CAP BOX 2 REFLECTOR HOOD BASE WITH WHEELS EMITTER S...

Страница 8: ...ted below Make sure the holes for the screws line up when sliding the pieces together DAYVA PREMIERE OUTDOOR HEATER Step 3 Place the cabinet on the base so that the three threaded studs pass through t...

Страница 9: ...d heater post onto the cabinet Secure with four screws Step 5 While the cabinet door is open locate the tank strap mounting slots on the sides of the cabinet Install the tank safety strap through thes...

Страница 10: ...of the hood and align the mounting holes From the outside insert four screws From the inside install one lock washer and one hex nut on each screw Tighten securely Step 7 Turn the hood emitter screen...

Страница 11: ...Any leaks will blow soap bubbles Repair any and all leaks by tightening union with wrench Once any and all leaks have been stopped the heater is ready for use DO NOT USE A FLAME FOR LEAK TESTING TESTI...

Страница 12: ...AT CANNOT BE REPAIRED YOU MAY REQUIRE REPLACEMENT PARTS OR A NEW L P TANK DISCONTINUE USE UNTIL THE NEW PARTS ARE INSTALLED IF YOU SMELL GAS DISCONTINUE USE UNTIL THE LEAK IS IDENTIFIED AND REPAIRED S...

Страница 13: ...ter fully assembling your Dayva heater turn on main gas supply and carefully recheck all fittings for leakage using soap water solution see page 10 If leak is discovered turn off gas immediately Repai...

Страница 14: ...osure free and clean from debris D Visually inspect burner flames Cleaning See page 19 for cleaning instructions Complete Shutoff Visually check the burner flame each time the heater is used Flames sh...

Страница 15: ...Screen Reflector Hood Manifold Orifice L P Tank not included LP Safety Strap Cabinet conceals connections and LP Tank Heater Base with Conceals Wheels Burner DAYVA PREMIERE OUTDOOR HEATER CONSTRUCTIO...

Страница 16: ...alve If thermocouple is too tight on valve it will limit the amount of millivolt electricity which keeps the valve flowing gas SOLUTION Loosen Thermocouple 1 Remove cover opposite side the control kno...

Страница 17: ...from the burner 4 With channel locks remove each screw 2 located directly under the burner by turning counter clockwise 5 Pull burner free from burner plate 6 The Orifice will now be exposed 7 Examine...

Страница 18: ...t and rinse with water Keeping your heater clean allows it to operate and provide years of service If a scratch occurs in a powder coated surface quickly touch up with an exterior acrylic based paint...

Страница 19: ...HS030 2 WIRE ELECTRODE FOR IGNITER FOR NATURAL LP UNITS HS030 3 THERMOCOUPLE FOR NATURAL LP UNITS HS030 5 CONTROL KNOB FOR NATURAL LP UNITS Contact the selling dealer or Call 714 842 9697 for current...

Отзывы: