DayTronic PC-HSICA Скачать руководство пользователя страница 2

Copyright © 1996, Daytronic Corporation.  All rights reserved.

No part of this document may be reprinted, reproduced, or used in any form or by
any electronic, mechanical, or other means, including photocopying and recording,
or in any information storage and retrieval system, without permission in writing from
Daytronic Corporation.  All specifications are subject to change without notice.

PC-HSICA is a trademark of Daytronic Corporation.

FCC Radio Frequency Compliance

Note: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules.  These limits are designed to provide rea-
sonable protection against harmful interference when the
equipment is operated in a commercial environment.  This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.  Operation of this equipment in a residential
area is likely to cause harmful interference, in which case the
user will be required to correct the interference at his own
expense.

Содержание PC-HSICA

Страница 1: ...INSTRUCTION MANUAL PC HSICA HIGH SPEED SERIAL INTERFACE CARD SB 1 ...

Страница 2: ... Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance ...

Страница 3: ... SPEED SERIAL INTERFACE CARD INSTRUCTION MANUAL Daytronic Corporation 2211 Arbor Blvd Dayton OH 45439 Tel 937 293 2566 Fax 937 293 2586 PC HSICA Instruction Manual v SB 1 Pub No PCHSICAM 1 Issued 4 96 Part No 91821 ...

Страница 4: ... Interface Protocol 2 5 1 Via Windows TERMINAL 2 6 2 Via DOS or BASIC Command Line 2 6 Illustrations 1 PC HSICA Programming Jumpers and Switches plus RS 232 C Interface Connector Pinout 2 1 2 Full Handshake Cabling Between the PC HSICA Card and a Daytronic 25 Pin Computer Interface Port 2 4 3 Full Handshake Cabling Between the PC HSICA Card and a Daytronic 9 Pin Computer Interface Port 2 5 Tables ...

Страница 5: ...When set to HSIC mode the PC HSICA performs the basic functions of the 16C650 UART but at the same time may be used with any conventional 16C550 compatible serial driver including the DOS MODE COM or BASIC OPEN COM command or the Windows TERMINAL program When set to 16C650 mode the PC HSICA is equivalent to a stand alone 16C650 UART with all its functional capability This mode of operation require...

Страница 6: ...1 2 This page intentionally blank ...

Страница 7: ...er software i e CTS DTR or CTS RTS 2 1 SETUP OF PC HSICA COMMUNICATIONS 2 2 a BOARD SETTINGS 3 2 1 Handshake Programming Jumpers 3 2 1 2 3 RTS DTR Default 1 2 DTR DTR 0 CLOSED 1 OPEN HSIC Programming Switches 0 CLOSED 1 OPEN 1 2 3 4 OPEN See Sections 2 a 2 and 2 a 3 for switch settings 25 Pin RS 232 C Interface Connector Pin 1 Ground Shield Pin 2 Transmitted Data Pin 3 Received Data Pin 5 Clear to...

Страница 8: ... CLOSED for 16C650 mode NOTE HSIC mode should normally be selected for operation with standard BASIC drivers and Windows TERMINAL and also when the PC HSICA is being used in conjunction with Daytronic StartPAC SuperPAC and related software 2 a 3 BUS ADDRESS COM PORT AND INTERRUPT LEVEL Switches 1 2 and 3 of the block of HSIC Programming Switches shown in Fig 1 are used to set a specific combinatio...

Страница 9: ... COMMAND LINE see Step 2 below IN YOUR PC S AUTOEXEC BAT FILE To enable the hardware based handshake provided by the PC HSICA interface you must use the HSIC EXE utility supplied with the card Application of HSIC EXE effectively initializes the PC HSICA board loading a set of default values into the UART registers that define the current mode of operation FOOTNOTE This includes the following inter...

Страница 10: ...ERATURE ACCOMPANYING YOUR SOFTWARE SERIAL DRIVER TO DETERMINE THE PRECISE HANDSHAKE THAT MAY BE CALLED FOR IF YOU ARE IN ANY DOUBT AS TO THE SUITABILITY OF A PARTICULAR CABLE CONFIGURATION FOR YOUR APPLICATION FEEL FREE TO CONTACT THE DAYTRONIC SERVICE DEPARTMENT FOR ASSISTANCE Note that it is NOT necessary to tie pins 5 and 6 at the PC HSICA end of the cable this is required only for direct conne...

Страница 11: ...ation between selected and actual baud rate values Table 2 PC HSICA Baud Rates Selected Actual Selected Actual Baud Rate Baud Rate Baud Rate Baud Rate 50 153 6K 3600 153 6K 75 153 6K 4800 4800 110 153 6K 7200 153 6K 134 5 153 6K 9600 9600 150 153 6K 19 2K 19 2K 300 153 6K 38 4K 38 4K 600 153 6K 56K 153 6K 1200 153 6K 115 2K 153 6K 2400 2400 153 6K 153 6K When the PC HSICA is set to 16C650 mode the...

Страница 12: ...ram 2 e 2 VIA DOS OR BASIC COMMAND LINE While in DOS you can use the MODE command to reset protocol for the PC HSICA interface For example to set the protocol to 153 6K baud 7 data bits 2 stop bits and NO parity for a PC HSICA that has been assigned to COM1 you can enter a command of C MODE COM1 150 n 7 2 or to set the COM2 protocol to 9600 baud 8 data bits 1 stop bit and EVEN pari ty you can ente...

Страница 13: ...Daytronic Corporation 2211 Arbor Blvd Dayton OH 45439 1521 800 668 4745 Tel 937 293 2566 Fax 937 293 2586 www daytronic com ...

Отзывы: