background image

1000W SUBWOOFER

PLATE AMPLIFIER

Model: SPA1000 User Manual

(4)

SPA-10

© 2009 Dayton Audio

®

SPECIFICATIONS:

Rated Power Output:  

(0.92 % THD) 497 Watts* into 8 ohms, 950 Watts* into 4 ohms
*Based on one-third power duty cycle

Signal to Noise Ratio: 

98 dB A-weighted

Effi ciency: 86%
Input Impedance: 

12K ohms

Low Pass Adjustment: 

30 Hz – 200 Hz

Phase Adjustment: 

0° (NOR) or 180° (REV)

 

Parametric EQ:

 Frequency: 

18 Hz – 80 Hz

 Bandwidth: 

0.1 – 1 Q

 Level: 

-14.5dB – +6dB

Dimensions: 

11-15/16" W x 11-15/16" H x 5-1/4" D

Enclosure Cutout: 

10" x 10"

Power Requirements: 

120/230 VAC, 50 Hz/60 Hz

Stand-by Power Rating:  120V  24W; 230V  18.4W
Weight: 

17 lbs.

NOTES ABOUT HUM:

While the SPA1000 has been designed to minimize the possibility of hum in the subwoofer system, it is still possible that a hum 
will occur in rare circumstances. Its safety grounding can create a path for small amounts of 60 Hz energy to travel through the 
line-level audio system. While not dangerous, this energy can cause diffi culty with the subwoofer auto signal sensing circuit, 
and at the very least will interfere with the quiet enjoyment of your system. The fi rst course of action should be trying to make 
sure that all of the audio components are connected to either the same electrical outlet, or at least into the same circuit branch. 
Next, cable TV systems are notoriously the culprit, so be sure to try disconnecting all coaxial feeds that are connected to the 
system. If this solves the problem, install a coaxial line isolator and reconnect the system. In the very worst case, a line-level 
audio isolator/transformer connected to the line-in of the subwoofer amplifi er will usually solve the problem.

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualifi ed personnel. 
To reduce the risk of fi re and shock do not expose unit to rain or moisture. The unit should be connected to an earth grounded AC 
electrical socket. The unit should be operated in a well ventilated area.  Minimum clearance is 2 inches from the ventilation openings.

Note: Unit is set at the factory for 120V operation. Be sure to change the fuse (5A rating) before switching to 230V operation.

daytonaudio.com

tel + 937.743.8248

[email protected]

705 Pleasant Valley Dr.

Springboro, OH 45066 

USA

5-Year Limited Warranty

See daytonaudio.com for details

Отзывы: