6

VI. Operation

1. Power on/off:

Open the battery compartment cover on the back of the shell, install batteries. Long press 

the power button to turn the unit on or off. After 3 seconds, the device will start and the 

initial value of 4000 FPM will be displayed. If measurement data has been stored after 

previous use, the latest measurement data stored will be displayed. 

2. Switch on the backlight:

Long press the “FINE/BL” button to activate the backlight, long press this key again to 

deactivate the backlight.

3. Switch on the light source: (Hold the STROBE button)

Flashing will begin when the device is powered on and the “TEST” button is held.

4. Tuning switch: (FPM mode only)

After you start the device, the “FINE/BL” button under FPM mode allows you to switch 

between coarse and fine tuning. In the case of fine-tuning, the “FINE” icon will appear on the 

left top of the display. In the case of coarse tuning, no prompt will appear.

5. Single-step regulation of rotation speed:

The “UP” button or the “DOWN” button controls the value of rotation speed will increase or 

decrease according to the step values described earlier in this manual.

6. Regulating the flashing frequency:

The device can also scan through speed settings continuously. Hold the “UP” or “DOWN” 

button, and the device will begin scanning.

In coarse mode, the device will automatically increase or decrease by 100FPM (when the 

tuning range≥1000FPM) or 10FPM (when the tuning range <1000FPM) every 0.2s. 

In fine mode, the device will automatically increase or decrease by 1FPM (when the tuning 

range≥1000FPM) or 0.1FPM (when the tuning range<1000FPM) every 0.2s.

Once you release the button, the device will stop scanning 

*

 (Regulation limits: In any mode, when the upper limit of 40000FPM / 665FPS is exceeded, 

the device will automatically remain at the 40000FPM / 665FPS. When the speed is lower 

than the lower limit of 60FPM / 1FPS, the device will automatically remain at 60FPM / 1FPS.)

7. Data storage function:

After adjusting the speed, press the “MEM” button in the center of the device panel to store 

the current value. The next time the device is started, the latest measurement data stored will 

be displayed. After saving, the pre-set data stored in the device can be retrieved at any time.

Содержание AS-1

Страница 1: ...AUDIOSTROBE HANDHELD DIGITAL STROBOSCOPE Model AS 1 UserManual...

Страница 2: ...on Audio AS 1 Audiostrobe was specifically designed with the loudspeaker enthusiast and professionals in mind The typical frequency response of a loudspeakers contains peaks nulls and or resonances wh...

Страница 3: ...automatically indicate when the power supply voltage is lower than required The ergonomic ABS plastic shell is solid and comfortable to operate Store up to 10 sets of flash frequency data to be retri...

Страница 4: ...symbol show on the LCD when the data is stored the symbol will disappear 3 Measuring symbol appears when measurement is in use 4 Frequency value in FPS or FPM 5 When indicated the AS 1 is in Flashes P...

Страница 5: ...n A Flash Light source B LCD C Strobe light button D Value increase button E MEM button FPM FPS convert F LCD backlight button G Power switch data retrieval button Coarse fine tuning switch button H V...

Страница 6: ...e value of rotation speed will increase or decrease according to the step values described earlier in this manual 6 Regulating the flashing frequency The device can also scan through speed settings co...

Страница 7: ...he object For example If the input frequency i e periodic movement of a loudspeaker is 25 Hz the loudspeaker will appear stationary at 50 75 100 FPS If the surface is obviously uneven or there are asy...

Страница 8: ...Dayton Audio Last Revised 8 3 2022 daytonaudio com tel 937 743 8248 info daytonaudio com 705 Pleasant Valley Dr Springboro OH 45066 USA 5 Year Limited Warranty See daytonaudio com for details...

Отзывы: