Daytona Users Instructions
200551_01
Page 3 of 4
Operation
The switch on the left hand side (marked with O/ bulb symbol) controls the lamp.
The next two switches operate the fan convector heater. To use the heater the middle of the
three switches marked O/I (O is off, I is on) should be operated first for 1 kW of heat. The
right hand switch also marked O/I should be used together with the middle switch to give
2kW of heat.
Thermostat:
The thermostat is mounted at the left-hand side on the bottom face of the heater box and can
be used to control the heat output to maintain a constant room temperature to suit user
requirements. This will ensure that excessive heat is not produced unnecessarily.
To set the temperature:
The knob is marked with numbers to indicate the maximum and minimum temperature
positions. Start with setting 9 and when the room has reached a desired level turn the knob
slowly to left until the thermostat just ‘clicks’ off. The thermostat will then maintain the room
at the selected level. To increase the temperature, turn knob back to right to a higher setting.
Note: - It is possible that if the room temperature is higher than the thermostat setting
it will not come into operation and the heater will remain off until the temperature of
the room cools.
Maintenance
Warning: Before undertaking any maintenance or cleaning disconnect appliance from main supply. Only competent persons should
service / repair appliances.
The area around the fire should be kept free of any materials such as lint or house dust (i.e. animal hair/ carpet fibres ) that could be
drawn into the internal workings of the appliance and hence affect the performance. We recommend that you clean around the fan
grille housing at regular intervals. This can be done using standard vacuum cleaner and suitable attachment.
Please note if the supply cord on this appliance is damaged it must be replaced by the manufacturer, Authorised Service Agent, or a qualified
person to avoid hazard.
Note: To prevent scratching of plastic and the front screen, this appliance should be cleaned with a damp cloth only.
Replacing the lamp:
•
Disconnect appliance from main supply.
•
Remove the two screws (located in the top corners) that secure the coal bed. Carefully lift to remove the coal bed.
•
Replace Lamp with either an Energy efficient – Mini Spiral lamp -230V-11w E14 (ELCC) available from Be Modern Ltd. Customer services
or alternatively a standard 230v-E14-SES -60 Watt- Clear candle lamp, hold the body of the lamp holder, if necessary, to prevent rotation.
DO NOT EXCEED 60 Watts.
•
Replace all components in reverse order of removal
.
Fault finding -– symptoms and cures:
It is highly unlikely you should have a fault with your heater, but should there appear to be a problem, please refer to the following checklist of
our most FAQ from customers. If these do not answer your query, please contact your retailer, or call us.
No light effect: Please check – does the heater still work? If Yes, – it will almost certainly need a new bulb. Check the bulb in a table lamp that
you know works. New bulb can be obtained from most electrical shops.
If No, – has the heater cut out operated? To protect against overheating please refer to the safety cut out paragraph. If still not working, first
change the 13Amp fuse in the plug with one you know works. Secondly, check the wall socket by plugging in a table lamp that you know works
on another socket. If this does not work, get an electrician to check the