 M4.2Si TimeLock User Manual

 

 

Firmware Updates  

 

o

  ‘

Check for update’

 checks DaySequerra’s FTP site against the firmware version on the 

M42Si for an available firmware update.  If an update is available an option to download 
and install will pop-up.  If the Firmware is up to date a message will pop-up displaying 
this – click ok to continue using the current firmware.  *It is good practice to periodically 
check for updates by selecting ‘Check for Update’.  

 

 

o

 

Local update

 allows the user to perform a firmware and webserver update from a local 

network drive

.  

See figure xx. 

 

 

o

 

‘Downgrade Firmware’

 enables the user to downgrade back to the last stable release 

stored on DaySequerra’s FTP site.  A pop-up message asks to continue or cancel. 

 

 

 

‘Reset Unit’

 performs a soft reboot of the M4.2 TimeLock™ unit

.   

 

  The  current  user  manual  is  always  available  for  download  by  selecting 

‘Download  Manual’

.  

This document is also available on our website 

www.daysequerra.com

.

 

 

 

Audio  Muting 

-  The  M4.2  TimeLock™  audio  output  can  be  set  to  automatically  mute  for 

received signals with signal strength less than 45dBf.  

 

 

 

De-Emphasis 

 

Switch  between  75

µ

sec  and  50

µ

sec.    M4.2  TimeLock™  is  set  to  75

µ

sec  by 

default. 

 

 

Region 

- US / Euro.  Adjusts tune spacing between 100 KHz (Euro) and 200 KHz (US – default)

 

 

 

Alarms Lock Tuning 

– Disables all tuning when any one alarm is enabled.

 

 

 

Digital  Auto  Force 

–  disables  the  tuner  from  falling  back  to  Analog  when  and  if  the  Digital 

signal drops below the threshold.  The tuner will mute in place of Analog.

 

 

 

About 

– Read-Only

 

o

 

Box ID – M4.2 TimeLock™ 

o

 

Serial # - Displays the unit serial number 

o

 

Firmware  Version  –  Displays  the  installed  firmware  version.    As  updates  are 
available and installed this number will update with it. 

 

A reset button performs a soft reboot of the M4.2 TimeLock™.  The most recent version of the M4.2 
TimeLock™ user manual is available at all times by clicking ‘Download’.   

 
4.    Network  Settings  window  – 

Configures  network  connections.    DHCP  is  enabled  by  default.  

Uncheck this box to disable DHCP.  IP Address, IP Subnet, Gateway are set here.  MAC is read only.  
Checking  the  ‘Display  IP  Address  Periodically  in  the  unit’  will  rotate  the  IP  address  in  with 
PAD/SIS/RBDS  scrolling  data.    After  the  Network  settings  are  saved  the  M4.2  TimeLock™  will  reset 
itself so the new network settings are enabled.  Selecting the Rest Unit button will remotely reset the 
unit. 

 
5.  About window – 

Read only window displaying important M4.2 TimeLock™ information:  Serial #, 

Firmware Version, and Box ID # 
 
 

Содержание TimeLock M4.2

Страница 1: ...M4 2 TimeLock AM FM HD Receiver User Manual...

Страница 2: ...l of our products has evolved through a process of user feedback extensive listening field testing and careful refinement In the event that you encounter any technical or operational difficulties with...

Страница 3: ...owners Specifications subject to change M4 2 TimeLock M4 2 TimeLock Features Robust 24 7 performance stays locked to AM FM analog HD 1 or selected multicast stream during power or I2E interruptions d...

Страница 4: ...e monitor ID and firmware version is momentarily displayed at start up for your convenience Please visit www daysequerra com and register your new M4 2 TimeLock so we can keep you informed of the late...

Страница 5: ...to 8 ohm Remote Dashboard provides total remote control and display of RBDS and all HD Radio PAD SIS network and alarm conditions along with audio level digital audio quality and carrier quality indic...

Страница 6: ...on Analog Digital and Headphone audio Alarm Notification Rear panel tallies front panel indications and email for loss of Audio Carrier and OFDM HD Radio Lock RBDS Data Pl Call Letters PS Program Ser...

Страница 7: ...to an AC mains outlet with a functional earth ground connection The M4 2 TimeLock has been set at the factory to operate at 120VAC unless otherwise specified on the shipping carton The M4 2 TimeLock...

Страница 8: ...f an HD RadioTM signal Multicast Blue LED illuminates when tuner has acquired OFDM of an HD RadioTM signal and there is at least one multicast signal present RF Level Bi colored LED Green indicates st...

Страница 9: ...volume control Press ENTER to exit and save the desired volume Rear Panel Figure 2 RF Input F Type 75 ohm AM FM 55 dBm Nominal 20 dBm Maximum Analog Audio Outputs Left Right Balanced XLR 4 dBm into 6...

Страница 10: ...ails which override IP PAD RBDS data 4 SNR Indicator Strength bars are displayed indicating the signal to noise ratio digital only 5 BAND PRESET AM and FM Bands are selected 25 AM and FM including Mul...

Страница 11: ...s mode provides for audio phase matching as well as audio level and time alignment of the HD RadioTM broadcast for the correct analog diversity delay Default mode is off Alarms Program Loss Monitor En...

Страница 12: ...k to the Alarm menu Audio Loss Silence Detect Threshold Navigate the arrow to Threshold and press ENTER to change the Threshold A blinking arrow will indicate the Threshold can be changed Low Medium a...

Страница 13: ...for the Analog MPS to move ahead or behind HD 1 Status Use the arrows to toggle between Enabled or disabled to turn the alarm ON and OFF default disabled Save Saves all conditions and exits back to t...

Страница 14: ...ated in figure 13 The factory default is set to US 200 KHz Press ENTER after making a selection to save and EXIT to the previous menu Figure 9 Diagnostics A Read Only menu that displays the SNR Signal...

Страница 15: ...CP is set to ON by default Disabling DHCP allows the users to manually enter an IP address subnet and gateway IP Exiting this menu will save and reset the M4 2 TimeLock The new manual IP address will...

Страница 16: ...le to be set within the SYSTEM tab M4 2 TimeLock Home Tab Frequency Displays the tuned frequency in a large bold font Read Only Tuning and Band selection Left and Right Arrows are used to navigate the...

Страница 17: ...ls the Station Long and Short Name Program Type Song Artist Album Genre Comments field RBDS scrolls the PI Call Letters PS Program Service PTY Program Type and RT Radio Text Any active alarm condition...

Страница 18: ...d TimeLock correlation Integer values are displayed in Samples and Msec Positive indicates Analog is leading HD 1 negative lags Green indicates Correlation above 70 and Red below Calculates the Analog...

Страница 19: ...itions are set with pull down windows Sliding the switch to the left side will ENABLE the alarm with the set conditions Orange switch indicates the alarm is enabled Relay Outputs are available for eac...

Страница 20: ...rivate FTP Settings An optional private FTP may be setup for firmware updates By default this feature is disabled Slide the switch to the left indicated in orange to Enable private FTP Email Notificat...

Страница 21: ...Test will send a test email to be sure it is configured properly SSL encrypted logins are currently unavailable coming soon in a future firmware release System Tab Network Time Firmware Updates Reset...

Страница 22: ...c M4 2 TimeLock is set to 75 sec by default Region US Euro Adjusts tune spacing between 100 KHz Euro and 200 KHz US default Alarms Lock Tuning Disables all tuning when any one alarm is enabled Digital...

Страница 23: ...the M4 2 TimeLock from downloading the update directly from DaySequerra Please notify DaySequerra so future firmware updates are sent directly to the user Restore Factory Settings To restore your M4...

Страница 24: ...all be void in the event a covered product has been damaged or failure is caused by or attributable to acts of God abuse accident misuse improper or abnormal usage failure to follow instructions impro...

Отзывы: