background image

4

6.  SAFETY WARNINGS

Do not restrict the exhaust silencer. 

There is a danger of overheating and fire.

Read  and  carefully  understand  the  Instruction 
Manual before before use.

Instruction 

Manual

Ensure a competent trained person is used in case 
of overhaul.

Do not use generator on a slope.

 Fuel spillage may occur and cause a fire.

Do not connect generators together

Generator damage will occur.

Avoid proximity to fire when refueling.

Highly inflammable!

!

Gasoline

Ensure good ventilation around the generator and 
do not operate indoors.

Exhaust gases are very poisonous.

AIR CLEANER:

 Check the air cleaner every time you use it and clean it every 3 

months or after 100 hours operations, whichever is sooner. Clean by blowing 
away accumulated dust and soaking in kerosene. 

Содержание DG 6000D

Страница 1: ...DG Portable Diesel Generators Installation Operating Manual DG 6000DS DG 6000D ...

Страница 2: ......

Страница 3: ...CATIONS 1 1 2 CONTROLS 2 ELECTRICAL CONNECTIONS 3 2 GENERATOR OPERATION 4 3 ROUTINE MAINTENANCE 5 3 INDEX Davis Shirtliff Ltd 2014 Contents herein are not warranted SAFETY WARNINGS 6 4 TROUBLE SHOOTING 7 5 WARRANTY 8 6 ...

Страница 4: ...available in both open and canopied configurations l High efficiency square core alternators providing increased power output and enabling operation of sensitive electronic equipment l AC auxillary current and DC welding current can be used simultaneously DGW l DC output for charging l Integrated control panel with voltmeter for operational convenience l Fuseless type over current protection l Oil...

Страница 5: ... 14 14 16 53 53 5 0 11 13 7 4 5 10 12 5 LA186FAFG LA290 LA290 DG6000D DG6000DS DG12000DSM DG12000DST Voltage V DGW 200D Electric 418 7 7 6 12 5 4 6 4 2 LA186 Welding Data Welding Performance No Load Voltage V Operation Voltage V Operating Current A 65 28 35 50 120 Welding Rod Currents A 2 5mmØ 50 100 3 2mmØ 100 160 DGW200D 4mmØ 160 180 Max Arching Current A 180 Model DERATING Given outputs are sea...

Страница 6: ...ator and powered accessories output must only be used briefly or generator damage will occur DC output to be used for charging automotive and solar 12V batteries only Ensure correct polarity when connecting cables i e ve to ve and ve to ve generator to battery terminals Ensure the generator is properly earthed Consult a qualified electrician if in doubt Ensure the total load does not exceed the ge...

Страница 7: ...pe Fuel spillage may occur and cause a fire Do not connect generators together Generator damage will occur Avoid proximity to fire when refueling Highly inflammable G a s o li n e Ensure good ventilation around the generator and do not operate indoors Exhaust gases are very poisonous AIR CLEANER Check the air cleaner every time you use it and clean it every 3 months or after 100 hours operations w...

Страница 8: ...engine oil Oil sensor is activated Add oil Oil sensor prevents engine from running if oil level is low Insufficient engine oil Check fuel cock open No fuel Clean if fuel filter blocked Battery flat Electric start Charge replace battery Check engine speed Reduce generator load Oil leakage from muffler or air cleaner Engine has tipped over Low Electrical output Low output voltage Excessive electrica...

Страница 9: ...petence on the part of the equipment user Acts of God or any other cause beyond the Company s reasonable control Also any repair or attempt at repair carried out by any other party invalidates all warranties ii Standard Warranty If equipment failure occurs in the normal course of service having been competently installed and when operating within its specified duty limits warranty will be provided...

Страница 10: ......

Страница 11: ......

Страница 12: ...INS182F 07 15 ...

Отзывы: