background image

1

1.  GENERATOR SPECIFICATIONS

The  DAYLIFF  Range  of  portable  petrol  generators  are  dependable,  quality  products 
specially  designed  for  mains  standby  and  remote  site  power  supply  applications. 
Particular features of all DG-P models are:

Ÿ

Reliable and economical air cooled OHV petrol engines equipped with large size 
exhausts and air cleaners for low noise operation.

Ÿ

High efficiency square core alternators providing consistent AC power output.

Ÿ

 DC output option for powering DC appliances (Not DG3000E)

Ÿ

Option  of  strong  tubular  frame,  trolley  mount  (T-suffix),  canopied  (S-suffix)  and 
Economy (E-suffix) low-cost models suited for lighter applications.

Ÿ

Integrated  control  panel  with  selection  of  different  controls  for  operational 
convenience

Ÿ

Fuseless type over current protection.

Ÿ

Oil alert system to stop engine in the event of low oil level(not DG950P, DG1200P).

Ÿ

High capacity fuel tank for extended operation (not DG950P).

 
Also  available  is  the  high  specification  DG4000PSi  model  that  includes  inverter 
technology with the following features:-

Ÿ

High specification petrol engine incorporating automatic speed control that adjusts 
engine  speed  to  load  leading  to  reduced  operation  fuel  consumption,  reduced 
emissions and quieter operation.

Ÿ

Square  core  alternator  fitted  with  a  digital  inverter  that  gives  regulated  50Hz 
frequency and perfect sine wave output suitable for all types of sensitive electronic 
equipment

Congratulations on selecting a Dayliff DG Generator. They are manufactured 
to  the  highest  standards  and  if  installed  and  operated  correctly  will  give 
many  years  of  efcient  and  trouble  free  service.  Careful  reading  of  this 
Installation  Manual  is  therefore  important,  though  should  there  be  any 
queries they should be referred to the equipment supplier.

Содержание DG 11000PS

Страница 1: ...DG 11000PS DG 950P DG 5000P DG 3800PT DGW DG Installation Operating Manual Portable Petrol Generators ...

Страница 2: ......

Страница 3: ...ICATIONS 1 1 2 SAFETY WARNINGS 3 CONTROLS 3 3 ELETRICAL CONNECTIONS 4 4 GENERATOR OPERATION 5 4 INDEX Davis Shirtliff Ltd 2021 Contents herein are not warranted ROUTINE MAINTENANCE 6 4 TROUBLE SHOOTING 7 5 WARRANTY 8 7 ...

Страница 4: ...il alert system to stop engine in the event of low oil level not DG950P DG1200P Ÿ High capacity fuel tank for extended operation not DG950P Also available is the high specification DG4000PSi model that includes inverter technology with the following features Ÿ High specification petrol engine incorporating automatic speed control that adjusts engine speed to load leading to reduced operation fuel ...

Страница 5: ...ectrical Data Alternator Brushless self exciting 2 pole Power Output 50Hz 240V single phase Voltage Regulator AVR Power Factor 1 Direct Current 12V 8 3A Speed 3000rpm GENERAL DATA Model DG950P DG1200P DG3000P DG3000E DG3800PT DG4000PSi DG5000P DG6500PT DG7500PS DG7500P DG9000PT DG11000PS Digital Multimeter Volts Hz Hours Digital Multimeter Volts Hz Hours Digital Multimeter Volts Hz Hours Digital M...

Страница 6: ...use generator on a slope Fuel spillage may occur and cause a fire Do not restrict the exhaust silencer There is a danger of overheating and fire Do not connect generators together Generator damage will occur Ensure a competent trained person is used in case of overhaul 3 CONTROLS All generators are fitted with the following Ÿ 2no 3 pin AC outlets ve and ve DC connections DG950 with one outlet Ÿ En...

Страница 7: ...k output voltage is 240V on the voltmeter If not adjust engine speed If the speed setting is correct and the voltage is low then the generator is overloaded and load must be reduced Ÿ If more than an appliance is connected apply load progressively with greatest load first Ÿ Close fuel valve whenever generator is not operating Ÿ DG950 generators use two stroke engines and oil must be pre mixed with...

Страница 8: ...en Clean if fuel filter blocked Battery flat Electric start Charge replace battery 7 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Ÿ Change engine oil after first month or after 20hrs operation and thereafter every 3 months or 50 hours of operation in both cases whichever is sooner AIR CLEANER Check the air cleaner every 3 months or after 50 hours operations whichever is the sooner Clean by blo...

Страница 9: ...6 PROBLEM POSSIBLE CAUSE SOLUTION Check engine speed Reduce generator load Low Electrical output Low output voltage Excessive electrical load ...

Страница 10: ...espect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Company s discretion defects which under proper use appear therein and arise solely from faulty design materials or workmanship within a specified period This period commences immediately after the equipment has been delivered to the customer and at its termination all liability ceases A...

Страница 11: ......

Страница 12: ...INS302G 02 20 ...

Отзывы: