Current

(A)

3

Pump

Power

Dimensions (mm)

Weight 

(kg)

kW

L

W

DN1

DN2

H

Pump Data

       Enclosure Class:

 IP44        

Insulation

 

Class:

 F         

Voltage:

1x240V

2.  INSTALLATION

Foot Valve

UPWARD SLOPE 
TO SUCTION

Max 5m

Min 50cm

•   Site in a dry, well ventilated and weather 

p r o o f   l o c a t i o n   w i t h   a n   a m b i e n t 

0

temperature of no more than 40 C.

Ÿ

Locate  on  a  solid  flat  surface  ensuring      
the shaft is in a horizontal position. 

Ÿ

Ensure  that  the  diameter  of  the  suction      
pipe  is  at  least  the  size  of  the  pump      
suction inlet. If the suction depth exceeds  
4 meters then a one size larger diameter   
pipe  should  be  used,  though  for 
maximum pump performance suction height should be minimised.

Ÿ

If there is negative suction (i.e. the pump is above the suction water level)  
the suction pipe must be slightly angled upwards towards the pump inlet to 
avoid the formation of air locks. It must also be immersed in water by at 
least 0.5m to avoid the formation of vortexes and a good quality foot valve 
must be fitted. 

Ÿ

Ensure that all suction pipe connections are completely airtight or else    
the  pump  will  not  operate.  The  diameter  of  the  delivery  pipe  must  be 
chosen to suit the flow rate and pressure required at the delivery point 
though must not be smaller than the pump outlet size. It is also advisable 
to fit a non-return valve and isolating valve on the delivery outlet. This 
measure is essential if the delivery pressure exceeds 20 meters.

DDJ750

0.75

5.2

1”

1”

435

191

200

17

DDP60

0.37

2.5

1”

1”

265

118

151

5.3

DDP65

0.75

5.2

305

136

181

10

DDS750

0.75

5.2

1”

315

213

232

14

1

1/”

4

1/”

DDJ1100

1.1

7

1

2

1”

515

209

218

32

DDG1000

0.8

2.5

1”

336

201

244

7

1”

DDC170

1.1

7

345

230

293

21

1

1/”

2

1

1/”

2

DDC158

0.75

5.2

1”

1”

305

190

260

13.8

1

1/”

2

1

1/”

2

Содержание DD

Страница 1: ...DD Domestic Pumps Installation Operating Manual DDP DDC DDJ DDS DDG...

Страница 2: ......

Страница 3: ...PUMP SPECIFICATIONS 1 1 2 INSTALLATION 3 ELECTRICAL CONNECTIONS 3 4 PRIMING 4 4 MAINTENANCE 5 5 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted TROUBLE SHOOTING 6 6 WARRANTY 7 7...

Страница 4: ...158 DDC 170 0 2 4 8 6 15 10 5 25 20 40 35 30 10 DDS 750 3 FLOW RATE m hr PUMP HEAD m DDS DDP 60 DDP 65 3 50 Congratulations on selecting a Dayliff Domestic Pump They are manufactured to the highest st...

Страница 5: ...ller stainless steel for DDC 158 and brass for DDC 170 DDJ Centrifugal jet type pumps that incorporate an integral ejector unit to provide highly effective self priming performance The pump body is ma...

Страница 6: ...ightly angled upwards towards the pump inlet to avoid the formation of air locks It must also be immersed in water by at least 0 5m to avoid the formation of vortexes and a good quality foot valve mus...

Страница 7: ...p rating plate Electrical connections must be made according to details in the pump junction box cover and effective earthing must be provided according to local regulations Single phase motors are pr...

Страница 8: ...regular intervals If the pump is to remain unused for long periods of time it is advisable to empty it completely rinse it with clean water and store in a dry place If the shaft does not run freely re...

Страница 9: ...k voltage and ventilation Release impeller See section on maintenance Motor turns without pumping Move pump closer to water level Check suction pipe is airtight Make sure foot valve is immersed by at...

Страница 10: ...udes defects caused by fair wear and tear the effects of careless handling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond...

Страница 11: ...Also proof of purchase including the purchase invoice must be provided for a warranty claim to be considered...

Страница 12: ...INS178F 09 16...

Отзывы: