DAYLIFF DB Скачать руководство пользователя страница 5

2

PUMP

The Dayliff DB/DBH range of horizontal multistage centrifugal pumps are 
designed for continuous duty in various water transfer duties with particular 
application  in  pumping  slightly  corrosive  liquids.  The  pump  has  small 
physical dimensions, axial suction port and radial discharge and is base 
plate mounted. DB suction chamber and pump head are made of grey cast 
iron while the impeller and impeller housing are of stainless steel. DBH pump 
body, suction and discharge ports are made from AISI 316 stainless steel as 
is all the other parts in contact with the pumped liquid. The mechanical seal is 
made from silicon carbide designed for easy replacement. Both pump and 
continuously  rated  motor  unit  are  of  monoblock  design  and  particular 
attention has been paid to quietness and smooth operation.

MOTOR

The pump is coupled to a totally enclosed, fan cooled single phase squirrel-
cage motor with built in thermal overload protection suitable for continuous 
duty.   The motor can be connected to a power outlet fuse or MCB and 
protection must be provided.

Enclosure Class:

DB2/4 & DBH - IP54, DB 8/12 - IP44 

                             

Insulation Class:

 F 

           

Voltage:

1x220-240V, 3x380-415 (DB8-50, DB12-50) 

                           

   

Speed:

2900rpm

OPERATING CONDITIONS

Pumped  Liquid: 

DB

  -  Thin,  clean,  non-aggressive  and  non-explosive 

liquids solid particles.

DBH 

- Thin, clean, slightly aggressive but non-explosive liquid without solid 

particles or fibres.

0

0

Liquid Temperature: 

0 C - 110 C

0

Max. Ambient Temperature:

 

+40 C

Max. Suction Lift:

 According to NPSH curve plus a safety margin of 1

0

Max. Operating Pressure:  

10 Bar up to 40 C 

0

  

                                               6 Bar up to 90 C

Содержание DB

Страница 1: ...DB DBH Horizontal Multistage Pumps Installation Operating Manual DB2 DB4 DB8 DB12 DBH...

Страница 2: ......

Страница 3: ...PUMP SPECIFICATIONS 1 1 2 INSTALLATION 2 ELECTRICAL CONNECTIONS 3 3 PRIMING 4 4 MAINTENANCE 5 4 INDEX Davis Shirtliff Ltd 2018 Contents herein are not warranted TROUBLE SHOOTING 6 5 WARRANTY 7 6...

Страница 4: ...5 30 25 40 45 50 DB 8 50 DB 8 30 1 2 3 4 5 6 7 8 9 10 HEAD m 20 2 4 6 8 10 12 14 5 0 10 15 35 30 25 40 45 50 55 DB 12 50 DB 12 30 DB2 DB4 DB8 DB12 3 FLOW RATE m hr 3 FLOW RATE m hr 3 FLOW RATE m hr Co...

Страница 5: ...rated motor unit are of monoblock design and particular attention has been paid to quietness and smooth operation MOTOR The pump is coupled to a totally enclosed fan cooled single phase squirrel cage...

Страница 6: ...on a solid flat surface ensuring the shaft is in a horizontal position Ensure that the diameter of the suction pipe is at least the size of the pump suction inlet If the suction depth exceeds 4 meters...

Страница 7: ...a thermal overload fitted in the motor windings Three phase motors should be installed with remote starter WARNING If there is negative suction i e the pump is above the suction water level the suctio...

Страница 8: ...problem remove the pump body by unscrewing the relevant mounting bolts and clean it thoroughly to remove any encrustation Never carry out any work on the pump without having first disconnected from t...

Страница 9: ...imed Clean foot valve Excessive suction height Air in suction Clogged foot valve Delivery head exceeds pump capacity Reduce delivery head Specify different pump Flow rate insufficient Reduce suction h...

Страница 10: ...liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Company s discretion defec...

Страница 11: ...8 Also proof of purchase including the purchase invoice must be provided for a warranty claim to be considered...

Страница 12: ...INS179E 05 18...