Dawlance EnerCon Inverter 15/30 Скачать руководство пользователя страница 6

05

ON/OFF 

Turns the unit on or off.

MODE

OK

TIMER

CLEAN

LED

Turbo

Scrolls through operation modes 

as follows:  

AUTO

 

g

 

 

COOL

   

DRY

g

g

 

HEAT

 

g

 

FAN

SWING

Increases temperate in 

1°C increments. 

Max. temperature is 

30°C.

TEMP

Used to confirm the selected 

functions

 

 

 

Starts and stops the horizontal 

louver movement. Hold down

for 2 seconds to initiate vertical

louver auto swing feature.

   Set timer to turn unit on or off

  

NOTE: 

HEAT mode is not supported 

  by the cooling only appliance.

Used to start/stop the Self

Clean function.

Turns indoor unit’s LED  display 

and air conditioner buzzer on and 

off (model dependent), which 

create a comfortable and quiet

environment.  

FAN SPEED

TEMP

Enables unit to reach preset

temperature in shortest possible

time.

   Selects fan speeds in the

   following order:  

   AUTO     LOW   MED    HIGH

g

g

NOTE: Holding this button 

down for 2 seconds will 

activate Silence feature.

g

Decreases temperature 

in 1 C increments.

Min. temperature is 17  C. 

O

O

 

SLEEP

  Saves energy during sleeping

  hours.

Model: 

RG10B1(D)/BGEF

FRESH

Used to start/stop the Fresh

feature.

 

Scrolls through operation

functions as follows:

Follow Me(     )     AP mode

(     )   

g

Follow Me(     )...

g

The selected symbol will 

flash on the display area, 

press OK button to confirm. 

SET

 

Fresh

Содержание EnerCon Inverter 15/30

Страница 1: ...lly and keep it for future reference Read This Manual Thank you for purchasing our air conditioner Please read this manual carefully before operating your new air conditioning unit Make sure to save t...

Страница 2: ...le of Contents Remote Controller Specifications 02 Handling the Remote Controller 03 Buttons and Functions 04 Remote Screen Indicators 07 How to Use Basic Functions 08 How to Use Advanced Functions 11...

Страница 3: ...and USER S MANUAL on function description the description of USER S MANUAL shall prevail 02 Remote Controller Specifications Quick Start Guide RG10B D BGEF RG10B D1 BGEFU1 RG10B1 D BGEF RG10B2 D BGCE...

Страница 4: ...the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Страница 5: ...OK button to confirm Used to start stop the Self Clean function Turns indoor unit s LED display and air conditioner buzzer on and off model dependent which create a comfortable and quiet environment F...

Страница 6: ...nction Turns indoor unit s LED display and air conditioner buzzer on and off model dependent which create a comfortable and quiet environment FAN SPEED TEMP Enables unit to reach preset temperature in...

Страница 7: ...which create a comfortable and quiet environment FAN SPEED TEMP Enables unit to reach preset temperature in shortest possible time Selects fan speeds in the following order AUTO LOW MED HIGH g g NOTE...

Страница 8: ...me feature display Wireless control feature display Low battery detection display If flashes Displays when LOCK feature is activated Lights up when remote sends signal to indoor unit Displays the curr...

Страница 9: ...EMP or TEMP button Set your desired temperature using the TEMP or TEMP button 3 Press the ON OFF button to start the unit Press the ON OFF button to start the unit NOTE FAN SPEED can t be set in AUTO...

Страница 10: ...ON OFF button to start the unit 1 Press the MODE button to select HEAT mode 2 3 Press FAN button to select the fan speed AUTO LOW MED or HIGH 4 4 1 3 2 1 3 2 DRY Mode dehumidifying NOTE FAN SPEED cann...

Страница 11: ...r 24 2 Cancel either function by setting its timer to 0 0h Point remote to unit and wait 1sec the TIMER ON will be activated Press TIMER button to initiate the OFF time sequence Point remote to unit a...

Страница 12: ...e actual room temperature Press more than 5 seconds again will revert back to display the setting temperature Press this button to turn on and turn off the display on the indoor unit 5s Press LED butt...

Страница 13: ...the ECO button again to stop it O O O O O O O O O O Clean Press ECO button to enter the energy efficient mode Note This function is only available under COOL mode ECO operation 5s 5s Turbo The unit wi...

Страница 14: ...es around heat exchanger in the unit With regular use most of this moisture is evaporated from the unit By pressing the CLEAN button your unit will clean itself automatically After cleaning the unit w...

Страница 15: ...al to the air conditioner every 3 minutes interval When using AUTO COOL or HEAT modes measuring ambient temperature from the remote control instead of from the indoor unit itself will enable the air c...

Страница 16: ...t Panel Display window for 3 seconds when FRESH SWING TURBO or SILENCE features are turned on when Fresh feature is activated some units for 3 seconds when TIMER OFF is set FRESH SWING TURBO or SILENC...

Страница 17: ......

Страница 18: ......

Отзывы: