Installing the Software

13

Software Installation and Setup

Refer to the following procedure and the WeatherLink 

Getting Started Guide

 

to install the WeatherLink software on your computer. The instructions below 
contain the basic procedures for running the WeatherLink software and setting 
up a connection to your Weather Envoy. All information about the software is 
included as an overview. Additional setup not featured in this manual is 
required for all Weather Envoy, and Vantage Pro2 consoles. See 

WeatherLink 

Online Help

 for complete setup instructions.

Note: 

If you are installing a Davis specialized data logger (6540, 6544, 6550,6560) please 
see the included addendum for complete installation instructions.

Installing the Software

Windows Computer Using USB, Serial, or IP Connection

Follow the steps below to install the WeatherLink software. 

1. Place the WeatherLink software CD in your CD ROM drive.

The install program should start automatically. If the install program does 
not start, select Run from the 

Start

 menu, type D:\SETUP (or the correct 

letter for your CD ROM drive), and click 

OK

 to begin the installation.

2. Follow the on-screen prompts to complete the installation.

Macintosh Computer

1. Place the Install Disk in your CD ROM drive.

2. Copy “install.sit” from the CD to your desktop and open it. 

3. The installation software will automatically extract itself.

4. Run “install.”

5. Follow the on-screen prompts to complete the installation.

Running the Software

To run the software, double-click the 

WeatherLink

 icon. See the 

WeatherLink 

Getting Started Guide

 or the 

Weatherlink Online Help System

 for information 

on running and configuring the software. 

Set Transceiver

Use the

 Set Transceiver

 dialog box to view and/or configure your Weather 

Envoy transmitter ID and repeater ID assignments and to control the 
retransmit function.

Note: 

Note: This dialog box is the only available tool for configuring the transmitter ID and 
repeater ID settings on your Weather Envoy.

Содержание Vantage Pro2 Updater

Страница 1: ...Vantage Pro2 Weather Envoy Manual For Vantage Pro2 Vantage Pro2 Plus and Vantage Vue Weather Stations Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisnet com...

Страница 2: ...installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the...

Страница 3: ...software and data logger the Weather Envoy allows you to view store plot analyze export share and print your weather data Contents Before continuing please be sure your Weather Envoy package includes...

Страница 4: ...band Router with one free port An Always on connection to the Internet A high speed DSL or cable internet connection that maintains constant connection to the internet Local Connection Macintosh Compu...

Страница 5: ...up or damage the logger The WeatherLink data logger must be installed before you install the batteries or plug in the AC power adapter Note Make sure the logger is plugged in firmly and completely 1 R...

Страница 6: ...place Inserting the Serial USB or IP data logger into the Envoy 4 Rejoin the case halves making sure the data logger cable passes through the cable channel 5 Fasten using the three screws you removed...

Страница 7: ...is Instruments Technical Support See Contacting Davis Technical Support on page 20 4 Replace the battery cover on the case Optional Connecting AC Power The operating battery power for a cabled Weather...

Страница 8: ...ware Optional Adding an External Temperature Probe Wireless Envoy Only Your wireless Weather Envoy has a built in temperature humidity sensor as well as the barometer The temperature and humidity are...

Страница 9: ...RJ jack on the Envoy Note Note It may take several minutes for the temperature reading to stabilize If the Envoy is mounted outside in a weather proof shelter you should thread the probe cable up thr...

Страница 10: ...sight 1000 feet 300 m Under most conditions 200 400 feet 60 120 m Other range and transmission considerations include Range may be reduced by walls ceilings trees foliage a metal roof or other large m...

Страница 11: ...7 64 2 2 to 2 7 mm drill bit 4 Drive the two 6 x 1 3 5 mm x 25 mm pan head self threading screws into the wall 5 Leave at least a 1 8 3 mm space between the wall and the heads of the screws 6 Slide t...

Страница 12: ...eatherLink Online Help for additional setup instructions USB Connection Locate a free USB port on your computer and connect the USB connector of the 8 cable to the port and connect the Mini B connecto...

Страница 13: ...imes occurring within one second of each other On power up the IP data logger will negotiate its connection with the router 6 Write down the Device ID and Key located on the side of the WeatherLinkIP...

Страница 14: ...ata logger may have difficulty communicating with the computer Warning Do not use phone cable Our cable looks like a phone cable but it is wired differently Note The data logger does not require a con...

Страница 15: ...n your CD ROM drive The install program should start automatically If the install program does not start select Run from the Start menu type D SETUP or the correct letter for your CD ROM drive and cli...

Страница 16: ...e Set Transceiver dialog box displays 2 Select a Station Type for each of the possible 8 transmitter IDs channels the Envoy may be receiving See the WeatherLink Online Help System for more information...

Страница 17: ...eep verifies the installation of the data logger If you do not hear two beeps contact Davis Instruments Technical Support 5 If you hear both beeps see Troubleshooting Serial Port Communication on page...

Страница 18: ...p menu The Communications Port dialog box displays 4 Click Loopback The software searches all standard ports and displays the COM port number where the loopback connector is located The correct COM po...

Страница 19: ...ug the cable back into the Envoy Open the WeatherLink software again Open the Communications Port dialog box Select USB if USB is not selected in the communications field and follow the prompts Click...

Страница 20: ...r up you will hear two beeps 6 Check if the green light on the WeatherLink IP data logger is on If it is not on contact Technical Support 7 For Weatherlink com Wait five minutes Go to www weatherlink...

Страница 21: ...at can I do The Vantage Pro2 system is smart enough to send only data it hasn t already sent to the computer So when you initiate a new download the program will retrieve the first record after the la...

Страница 22: ...led in your weather station be sure check the Station Configuration in the Setup Menu and make sure the sensor has been selected Contacting Davis Technical Support If you have questions about the Envo...

Страница 23: ...he temperature of liquids such as water Apparent Temperatures The Weather Envoy calculates four apparent temperature readings wind chill heat index the temperature humidity wind index THW Index and th...

Страница 24: ...at the air can contain varies with air temperature and pressure Relative humidity takes into account these factors and offers a humidity reading which reflects the amount of water vapor in the air as...

Страница 25: ...ayed Converting at display time reduces possible compounded rounding errors over time Four separate variables track rain totals rain storm daily rain monthly rain and yearly rain Rain rate calculation...

Страница 26: ...ess the immune system The Weather Envoy can help analyze the changing levels of UV radiation and can advise of situations where exposure is particularly unacceptable CAUTION Be aware that the UV senso...

Страница 27: ...2 Sometimes tans usually burns Very light brown sometimes freckles Usually burns pinkish or red coloring appears can gradually develop light brown tan 3 Usually tans sometimes burns Light tan brown o...

Страница 28: ...opted by the World Meteorological Organization UV Index assigns a number between 0 and 16 to the current UV intensity The US EPA categorizes the Index values as shown below The lower the number the lo...

Страница 29: ...ss sensor 6420 Leaf wetness provides an indication of whether the surface of foliage in the area of the sensor is wet or dry by indicating how wet the surface of the sensor is The leaf wetness reading...

Страница 30: ...y Transmit Receive Frequency US Models 902 928 MHz FHSS Overseas Models 868 0 868 6 MHz FHSS ID Codes Available 8 Output Power 902 928 MHz FHSS FCC certified low power less than 8 mW no license requir...

Страница 31: ...or slowly Steady or Falling rapidly or slowly Update Interval 1 minute Current Data Instant 15 min and Hourly Reading Daily Monthly High and Low Historical Data 15 min and Hourly Reading Daily Monthl...

Страница 32: ...se Sunset Report F7 NOAA This Month F8 NOAA This Year Strip Chart Window ESC Halt Redraw Ctrl M Make Default Ctrl P Print Strip Chart F1 Context Sensitive Help F3 Zoom In F4 Zoom Out Plot Window ESC H...

Отзывы: