DAVIS Vantage Pro2 Plus Скачать руководство пользователя страница 55

52

In the example below, the console is set up to receive an ISS station on transmitter 
ID 1 from repeater A.

6. For each station using a repeater, select the station and turn on the repeater function 

and select the correct repeater ID.

7. Press DONE to continue to the other screens in the Setup Mode, or press and hold 

DONE to return to the Current Weather Mode.

Note: 

In console with the October 2005 version of firmware, the only way to exit Repeater Setup mode is 
to press DONE to continue to the next setup screen. 

Verifying Setup

To verify that you have successfully set up your console to receive a repeater in the 
console’s Current Weather Mode:

View the transmitter information displaying at the bottom of the console screen. 
If the transmitter ID being repeated is displayed and an “X” flashes in the bottom 
right-hand corner of the ticker tape, the transmitter is being repeated and received by 
the console successfully.

The repeater’s information also displays at the bottom of the console’s diagnostics 
screens.

Clearing Repeater ID

If a repeater ID is being displayed in Screen 2 and you are not using a repeater with the 
selected station, you must turn off the repeater function to receive station information 
successfully. 

In Setup Screen 2:

For consoles with May 2005 firmware, press WIND repeatedly so that the console 
cycles through the list of repeater IDs (Repeaters A-H) until the section where the 
repeater ID was displayed is blank. Press DONE to continue to the next screen or press 
and hold DONE to return to the Current Weather Mode.

For consoles with October 2005 firmware, press 2ND and then press WIND repeatedly 
so that the console cycles through the list of repeater IDs (Repeaters A-H) until the sec-
tion where the repeater ID was displayed is blank. Press DONE to continue to the next 
screen or press and hold DONE to return to the Current Weather Mode.

                      1

Содержание Vantage Pro2 Plus

Страница 1: ...Vantage Pro2 Console Manual For Vantage Pro2 Vantage Pro2 Plus Weather Stations Davis Instruments 3465 Diablo Avenue Hayward CA 94545 510 732 9229 www davisnet com ...

Страница 2: ...ned by turning the equipment on and off the user is encouraged to try to cor rect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technic...

Страница 3: ... Displaying Time Date or Sunrise Sunset 24 Calibrating Setting and Clearing Variables 24 Highs and Lows Mode 27 Alarm Mode 29 Graph Mode 31 Troubleshooting and Maintenance 34 Vantage Pro2 Troubleshooting Guide 34 Console Diagnostic Screens 36 Console Maintenance 40 One Year Limited Warranty 40 Appendix A Weather Data 41 Appendix B Specifications 47 Console Specifications 47 Wireless Communication ...

Страница 4: ...nt and historical data set and clear alarms change station models enter calibration numbers set up and view graphs select sensors and read the forecast The keyboard consists of 12 command keys located next to the screen display and four navigation keys located below the command keys A weather variable or console command is printed on each com mand key Just press a key to select the variable or fun...

Страница 5: ...rather place the console in another location for viewing weather conditions Anemometer Transmitter Kit 6332 Provides more flexible anemometer placement for wireless stations Wireless Leaf Soil Moisture Temperature Station 6345 Measures and transmits leaf wetness soil moisture and temperature data For use with GLOBE Wireless Temperature Station 6372 Measures and transmits temperature data Wireless ...

Страница 6: ... two toned with a washed khaki crown dark blue brim and embroidered Davis logo Self fabric closure with brass buckle One size fits all WeatherLink for APRS Windows version with streaming data logger serial connection 6540 Includes WeatherLink software and streaming serial data logger Allows real time display of current weather conditions for use with APRS Automatic Position Reporting System for HA...

Страница 7: ...power supply The console batteries pro vide backup power for up to four to six weeks Wireless Vantage Pro2 Stations Wireless Vantage Pro2 consoles do not require the use of an AC adapter You may use the included adapter if you wish but the three C cell batteries should power a wireless console for up to nine months Note When using an AC Power adapter be sure to use the power adapter supplied with ...

Страница 8: ... on page 9 for more information Installing Batteries 1 Remove the battery cover located on the back of the console by pressing down on the two latches at the top of the cover 2 Insert three C batteries into the battery channel negative or flat terminal first 3 Replace the battery cover Connecting Cabled Stations Cabled Vantage Pro2 stations come with 100 feet 30m of cable This cable is used for co...

Страница 9: ...onnection see Cabled ISS Assembly in the Integrated Sensor Suite Instal lation Manual Console Location You should place the console in a location where the keyboard is easily acces sible and the display is easy to read For more accurate readings follow these suggestions Avoid placing the console in direct sunlight This may cause erroneous inside temperature and humidity readings and may damage to ...

Страница 10: ...e kickstand out by pulling on its top edge You ll see the indentation for your finger at the top edge of the console 3 Slide the catch to rest the kickstand in the appropriate angle Choose low angles for display on a coffee table or other low area Choose higher angles for display on a desk or shelf 4 Install the two rubber channel feet on the kickstand If necessary pull up on the stand to close it...

Страница 11: ...e running inside the wall mount the console over an empty switch box 2 Use a drill and a 3 32 or 7 64 2 5 mm drill bit to drill two pilot holes for the screws 3 Using a screwdriver drive the two 6 x 1 pan head self threading screws into the wall Leave at least 1 8 3 mm between the wall the heads of the screws 4 If the kickstand has been pulled out from the case push it back into its upright and lo...

Страница 12: ...tting Started Guide for more information on connecting your con sole to your computer Setup Mode Commands Setup Mode displays when the console is first powered This mode can be dis played at any time to change any of the console weather station options Use the following commands to enter exit and navigate Setup Mode Enter Setup Mode by pressing DONE and the down arrow at the same time Note The con...

Страница 13: ...next screen The console can receive signals from up to eight transmitters total but there is also a limit on the number of certain types of transmitters The table below lists the maximum number for each type of transmitter Maximum Number of Transmitters Note Listening to more than one transmitter may reduce battery life significantly Screen 2 Configuring Transmitter IDs Wireless Only If you have a...

Страница 14: ...pendix C on page 51 for configuring repeaters on the console Screen 3 Retransmit Wireless Only Press DONE and go to Screen 4 Time Date on page 12 if you have a cabled station The console can take data it receives from the ISS and transmit it to other Van tage Pro2 consoles using the retransmit feature By toggling the feature on the console becomes another transmitter that requires its own unique I...

Страница 15: ...er the hour or minute setting then press 2ND and immediately press UNITS This toggles the clock setting between the two clock types To choose between a MM DD or DD MM display for the date first select either the day or month setting then press 2ND and immediately press UNITS This switches the console from one date display to the other 3 Press DONE to move to the next screen Screen 5 Latitude The c...

Страница 16: ... through Greenwich England Longitude is used with latitude to identify your position on earth 1 Press the right and left arrows to move between fields 2 Press the up and down arrows to change the settings up or down 3 To select the East or West Hemisphere press 2ND then UNITS 4 Press DONE to move to the next screen Screen 7 Time Zone The console is pre programmed with a combination of US time zone...

Страница 17: ...ght Savings Time in these areas based on the time zone setting in screen 7 Weather stations located outside of North America Europe and Australia or in areas that do not observe daylight savings time should use the MANUAL set ting Screen 8 Daylight Savings Settings 1 Press the up and down arrows to choose Auto or Manual 2 Press DONE to move to the next screen Screen 9 Daylight Savings Status Use t...

Страница 18: ...he 0 immediately to the left of the left most non zero digit the second zero from the left in 0026 for example or the first zero from the left in 0207 and press the up and down arrows to switch from a positive to negative elevation Note You can only set the elevation to negative after you have entered a non zero digit and when the zero in the position immediately to the left of the left most non z...

Страница 19: ...ndard measure ment or the metric adapter installed in the rain bucket Note If necessary the console can be configured to calculate the 0 01 measurements and convert these to metric measurements rounding to the nearest 0 1 mm or can be configured to calculate the 0 2 mm measurements and convert them to the U S standard rounding to the nearest 01 To Display Rain in Metric Units on the Console Even i...

Страница 20: ...that a WeatherLink data logger installed on the console The console uses a serial or USB port to communicate with a computer If you are connecting the console directly to your computer leave the setting at 19200 the highest rate for the port If you re using a modem use the highest setting your modem can handle The console must be equipped with a Weath erLink data logger to communicate with a compu...

Страница 21: ...iables You can select any variable not currently on the screen to display it Selecting Weather Variables Select a weather variable to display it s data on the screen if it isn t already visible or to graph the data available for that variable Weather variables are selected via the console command keys If the variable is printed on a key just press the key to select the variable If the variable is ...

Страница 22: ...ess UNITS Repeating these steps cycles through the units available for Baro metric pressure millibars millimeters inches and hectoPascals Wind Speed and Direction 1 Press WIND to select wind speed 2 Wind speed may be displayed in miles per hour m p h kilo meters per hour km h meters per second m s and knots knots The 10 minute average wind speed will be displayed in the ticker A solid arrow within...

Страница 23: ...o your console The order the optional sensors readings display depends on your station configuration Temperatures for temperature stations display with soil temperature and moisture stations displaying consecutively Humidity Press HUM to select outside humidity Pressing HUM a second time selects inside humidity Humidity is displayed in percent relative humidity Each consecutive press of HUM displa...

Страница 24: ... hours of data in order to be calculated so it won t display right away on a new station The pressure trend is indicated on the console screen as long as the required data is available UV Ultraviolet Radiation Press 2ND and UV to display the current UV index The cur rent UV index is the amount of ultraviolet radiation the sensor is currently reading Press 2ND and UV again to display the accumulate...

Страница 25: ...cord Monthly rain displays the precipitation accumulated since the calendar month began Month to date precipitation is displayed in inches or millimeters mm Year to date precipitation Press RAINYR a third time to display the year to date precipitation record Yearly rain displays the precipitation accumulated since the 1st of the month you ve chosen as the beginning of your rain year in Setup Mode ...

Страница 26: ...ress ET then repeat this key sequence two more times to dis play the ET reading since January 1st of the current year Note A solar radiation sensor is required to take readings listed above See Optional Sensors on page 2 Lamps Press 2ND then press LAMPS to turn on the backlight for the screen display Press 2ND then LAMPS again to turn the backlight off Use the backlight when the LCD is not clearly...

Страница 27: ...timing severity and windy conditions Forecast Icons The forecast icons show the predicted weather for the next 12 hours If rain and or snow is possible but not necessarily likely the partly cloudy icon along with the rain or snow icon displays When both the rain and snow icons display together a chances of rain freezing rain sleet and or snow are likely Displaying Time Date or Sunrise Sunset Your ...

Страница 28: ... Reading You can use this procedure to correct the anemometer reading This is useful if the anemometer does not point north in your installation 1 Check the current direction of the wind vane on the anemometer Compare it to the wind direction reading on the console If the wind vane is pointing south for instance the wind direction reading on the screen should be 180 If the wind direction reading i...

Страница 29: ...ated Monthly Rain Sets the current months total rain Does not affect yearly rain total Yearly Rain The sets the current year s rain total Daily ET Evapotranspiration This sets the daily ET total Monthly and yearly ET totals are updated Monthly ET This sets the current month s ET Does not affect yearly total Yearly ET This sets the current year s total ET To set a weather variable s value 1 Select ...

Страница 30: ...ding the key until the value changes to zero or in the case of the barometer the raw barometer value Clearing the barometer value also clears the elevation setting Clear All Command This command clears all stored high and low weather data including monthly and yearly highs and lows and clears alarm settings all at once 1 Press WIND on the console 2 Press 2ND then press and hold CLEAR for at least ...

Страница 31: ...ot is the present day As you move backward and forward the flashing dot changes to show what value you re looking at Weather Variable High Low Day Time Date Month Year Additional Information Outside Temperature Yes Yes Yes Yes Yes Inside Temperature Yes Yes Yes Yes Yes Outside Humidity Yes Yes Yes Yes Yes Inside Humidity Yes Yes Yes Yes Yes Barometer Yes Yes Yes Yes Yes Heat Index Yes Yes Yes Yes ...

Страница 32: ...und again for each new alarm If more than one alarm is active the description for each active alarm cycles onto the screen every four seconds A symbol appears at the end of the alarm text if more than one alarm is tripped Low alarms work the same way For example if the wind chill threshold is set for 30ºF the alarm condition begins when the wind chill drops to 30º and will continue until the wind ...

Страница 33: ...e currently selected weather variable 4 Press the right and left arrows to select digits in the threshold value 5 Press the up and down arrows to change the digit s value up and down 6 Press DONE to finish changing the alarm setting 7 Repeat steps 3 through 6 to change additional alarm settings 8 Press DONE to exit Alarm Mode Setting the Time Alarm 1 Press ALARM to enter alarm mode The ALARM and H...

Страница 34: ...e day Humidity Inside High and Low Humidity Outside High and Low Dew Point High and Low Leaf Wetness High and Low Rain Flash Flood Alarm uses current 15 minute rainfall total 24 Hour Rain Alarm uses current 24 hour rainfall total Storm Storm Alarm uses current storm rainfall total Rain Rate High Soil Moisture High and Low Solar Radiation High Inside Temperature High and Low Outside Temperature Hig...

Страница 35: ...24 hours 5 Press the up and down arrows to shift the graph s time span If you press the down arrow the graph shifts from the last 24 hours to the last 24 days Now each dot represents the high recorded on the day shown in the date field To see the lows recorded in the last 24 days press HI LOW Press the left and right arrows to move between days By pressing the down arrow again the graph shifts to ...

Страница 36: ...de C C H L H L Dew Point C C H L H L Leaf Wetness C C H L Rain T T T T T T Storm Rain Rate H H H H H H Soil Moisture C C H L Solar Radiation A A H Inside Temperature C C H L H L Outside Temperature C C H L H L H L Heat Index Temperature C C H H Temp Hum Sun Wind THSW Index C C H H Wind Chill Temperature L L L L UV Radiation Index A A H C UV Radiation MED Minimal Erythermal Dose T T T Wind Speed A ...

Страница 37: ...onsole is sluggish or does not work at low temperatures The console and display may not work below 32º F 0º C Use an External Temperature sensor in low temperature locations or install the console indoors Display locks up If the console locks up reset the console by removing AC and bat tery power then restoring power If this occurs frequently in an AC powered console plug the AC power adapter into...

Страница 38: ...e temperature sensor reading seems too low Make sure the console or other temperature sensor is not in contact with an exterior wall that cools down when outside temperature drops Make sure the console or other temperature sensor is not near an air conditioning vent Check calibration number and adjust if necessary Wind Direction Wind direction reading is dashed out Wireless model check reception S...

Страница 39: ...ISS Refer to the ISS Installation Manual for instructions on how to check the ISS for potential transmission problems Console Diagnostic Screens In addition to logging weather data the console continuously monitors the sta tion s radio reception You may find this information very helpful especially when you are choosing locations for your console and ISS Console Diagnostics consists of two screens...

Страница 40: ...er of times the reed switch was seen open is displayed Use WIND to toggle between these two values Note The time of day and date displays can be toggled in both statistical and reception diagnostic screens 3 Number of packets containing errors that were received 4 Number of missed data packets 5 Percentage of packets received without errors 6 Total number of packets received 7 Number of times the ...

Страница 41: ...Background Noise Level displays the receiver gain is automatically adjusted to obtain the best sensitivity and does not need to be controlled manually 13 Alternate View Receiver Gain Status Some versions of the console display receiver gain status and not back ground noise level The receiver gain status setting allows you to control the gain setting of the console Press HI LOW to toggle Gain on an...

Страница 42: ...out 5 Current frequency correction factor 6 Frequency index of the next packet to be received 7 Current number of consecutive packets missed 8 The number of times that the Phase Lock Loop did not lock 9 Current streak of consecutive packets received Console Firmware Versions In some cases the problem may be that your console firmware doesn t support what you are trying to do Use this command to de...

Страница 43: ...n the back of the console by pressing down on the two latches at the top of the cover 3 Place the console face down on a flat firm surface 4 Insert a fingertip between the two exposed batteries then press the middle battery down toward the notch toward the hidden battery This will relieve tension on the first battery and allow you to remove it 5 Remove the old batteries and install the new batteri...

Страница 44: ...ent temperature readings Wind Chill Heat Index and the Temperature Humidity Sun Wind THSW Index Appar ent temperatures use additional weather data to calculate what a human body perceives the temperature to be in those conditions Wind chill Wind chill takes into account how the speed of the wind affects our perception of the air temperature Our bodies warm the surrounding air molecules by transfer...

Страница 45: ... we use the term humidity in the manual and on the screen we mean relative humidity It is important to realize that relative humidity changes with temperature pres sure and water vapor content A parcel of air with a capacity for 10 g of water vapor which contains 4 g of water vapor the relative humidity would be 40 Adding 2 g more water vapor for a total of 6 g would change the humidity to 60 If t...

Страница 46: ...ude For example atmospheric pressure is greater at sea level than on a mountaintop To com pensate for this difference and facilitate comparison between locations with different altitudes atmospheric pressure is generally adjusted to the equivalent sea level pressure This adjusted pressure is known as barometric pressure In reality the Vantage Pro2 measures atmospheric pressure When you enter your ...

Страница 47: ... MED Minimum Erythemal Dose is defined as the amount of sunlight expo sure necessary to induce a barely perceptible redness of the skin within 24 hours after sun exposure In other words exposure to 1 MED will result in a reddening of the skin Because different skin types burn at different rates 1 MED for persons with very dark skin is different from 1 MED for persons with very light skin Both the ...

Страница 48: ...gmentation a Developed by T B Fitzpatrick of the Harvard Medical School More about the Fitzpatrick Skin Types is available in Fitzpatrick TB Editorial the validity and practicality of sun reactive skin types I through VI Arch Dermatol 1988 124 869 871 Table A 2 ENVIRONMENT CANADA SKIN TYPES AND REACTION TO THE SUN a Skin Type Skin Color History of Tanning Sunburning UV Dose that Causes Sunburn All...

Страница 49: ...face of the sensor is The leaf wetness reading ranges from 0 dry to 15 Leaf wetness requires an optional Leaf Soil Moisture Temperature Station and is only available for Wireless Vantage Pro2 Stations Soil Moisture Soil Moisture as the name suggests is a measure of the moisture content of the soil Soil moisture is measured on a scale of 0 to 200 centibars and can help choose times to water crops T...

Страница 50: ...e no AC power Wireless up to 9 months Cabled 1 month approximately Connectors Modular RJ 11 Housing Material UV resistant ABS plastic Console Display Type LCD Transflective Display Backlight LEDs Dimensions Console with antenna 10 375 x 6 125 x 1 5 264 mm x 156 mm x 38 mm Console no antenna 9 625 x 6 125 x 1 5 244 mm x 156 mm x 38 mm Display 5 94 x 3 375 151 mm x 86 mm Weight with batteries 1 88 l...

Страница 51: ...n vari able selected Graph Time Span 24 Intervals Current Interval see Graph Intervals to determine time span Graph Variable Span Vertical Scale Automatic varies depending upon data range Maximum and minimum value in range appear in ticker Alarm Indication Alarms sound for 2 minutes time alarm is 2 minute if operating on bat tery power Alarm message displays in ticker as long as threshold is met o...

Страница 52: ...reater of 5 or 0 01 0 25 mm Inside Humidity Included in Console 1 10 to 90 5 RH Outside Humidity ISS or Temp Hum Station 1 0 to 100 3 RH 4 above 90 Extra Humidity ISS or Temp Hum Station 1 0 to 100 3 RH 4 above 90 Dew Point overall ISS or Temp Hum Station 1 F 1 C 105 to 130 F 76 to 54 C 3 F 1 5 C Leaf Wetness Leaf Soil Station 1 0 to 15 0 5 Soil Moisture Leaf Soil Station or Soil Moisture Station ...

Страница 53: ... MED 20 1 MED 20 0 to 199 MEDs 5 Wind Direction Anemometer 1 0 to 360 7 Compass Rose 22 5 16 compass pts 0 3 compass pt Wind Speed large cups 1 mph 1 kt 0 5 m s 1 km h 2 to 150 mph 2 to 130 kts 3 to 241 km h 1 to 68 m s greater of 2 mph kts 1 m s 3 km h or 5 Wind Speed small cups 1 mph 1 kt 0 5 m s 1 km h 3 to 175 mph 3 to 150 kts 1 5 to 79 m s 5 to 282 km h greater of 3mph 3 kts 1 m s 5km h or 5 ...

Страница 54: ...the down arrow to enter Setup Mode 2 If Setup Mode has previously been completed press DONE to display Screen 2 Configuring Transmitter IDs 3 See Screen 2 Configuring Transmitter IDs Wireless Only on page 10 for more information on configuring Transmitter IDs Note The way the Repeater ID information is accessed depends on the firmware version available on the console If the firmware is dated May 2...

Страница 55: ...ticker tape the transmitter is being repeated and received by the console successfully The repeater s information also displays at the bottom of the console s diagnostics screens Clearing Repeater ID If a repeater ID is being displayed in Screen 2 and you are not using a repeater with the selected station you must turn off the repeater function to receive station information successfully In Setup ...

Страница 56: ...etecting rain Barometric Pressure Trend Arrows show direction of pressure change for last three hours Contacting Davis Technical Support If you have any questions or encounter problems installing or operating your Van tage Pro 2 weather station please contact Davis Technical Support We ll be glad to help 510 732 7814 Monday Friday 7 00 a m 5 30 p m Pacific Time We are unable to accept collect call...

Отзывы: