background image

0

FCC Part 15 Class B Registration Warning

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference, including interference received, including inference that may cause undesired operation. 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to 
the following two conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit 
pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioelectrique subi, même si 
le brouillage est susceptible d'en compromettre le fonctionnement

Innovation, Science and Economic Development Canada ICES-003 Compliance Label: CAN ICES-3 
(B)/NMB-3(B)

Changes or modification not expressly approved in writing by Davis Instruments may void the warranty 
and void the user's authority to operate this equipment.

FCC ID: IR2DWW6805     IC: 3788A-6805

Contains: FCCID: 2AC7Z-ESPWROOM02    IC: 21098-ESPWROOM02

The antenna used for this transmitter must be installed to provide a separation distance of at least 20 
cm from all persons and must not be co-located or operating in conjunction with any other antenna or 
transmitter.

If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment on and off, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.

Consult the dealer or an experienced radio/TV technician for help.

This radio transmitter 3788A-6805 has been approved by Innovation, Science and Economic
Development Canada to operate with the antenna types listed below, with the maximum permissible
gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain
indicated for any type listed are strictly prohibited for use with this device.The following antennas are
permissible to use with this product:
AMXF-9092-8 8dBi 50 Ohms
AMXF-9092-6 6dBi 50 Ohms
AMXF-9092-5 5dBi 50 Ohms

EC-Declaration of Conformity

Directive 2014/53/EU (RED Directive)

Manufacturer/responsible person:

 Davis Instruments 
 Compliance Engineer
3465 Diablo Ave., Hayward, CA 94545 USA

Declares that the products: 6805EU, 6805 UK

Comply with the essential requirements of 2014/53/EU, if used for its intended use. The complete Declara-
tion of Conformity is on our website at https://www.davisinstruments.com/legal.

The technical documentation relevant to the above equipment will be held at: Davis Instruments at 3465 Diablo 
Ave, Hayward CA 94545
Power Output: see page 18: 

Specifications

 

Содержание EnviroMonitor 6810

Страница 1: ...Product number 6810 and 6805 USER MANUAL Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisinstruments com R Ethernet Gateway and Node...

Страница 2: ...er s authority to operate this equipment FCC ID IR2DWW6805 IC 3788A 6805 Contains FCCID 2AC7Z ESPWROOM02 IC 21098 ESPWROOM02 The antenna used for this transmitter must be installed to provide a separa...

Страница 3: ...way This manual will show you how to set up both the EnviroMonitor Gateway and Nodes If you are just installing a Node and have already installed the Gateway you can skip to page 9 Set Up Nodes and Se...

Страница 4: ...r will block signals If transmitting under a canopy or in an orchard range will be reduced Mount the devices as high above the ground or the highest crop height as possible The higher they are mounted...

Страница 5: ...lation to get an idea of where the Gateway and Nodes should go SAMPLE FARM Vegetables Almonds East Almonds West Peppers H w y 1 0 Davis Rd Strawberries G N N N N N N N N N N N N Diablo Creek Gateway N...

Страница 6: ...either two or more other Nodes or the Gateway and another Node A Node can even be installed simply to transmit data from more distant Nodes to the Gateway without any sensors installed in it By planni...

Страница 7: ...ntents of Gateway Ethernet Gateway Requirements Tools Wi Fi or router Ethernet internet connection Wi Fi password Smartphone 4 AA batteries not included Ethernet Gateway AC Adapter Blue LED Capacitive...

Страница 8: ...or app will guide you through creating an account on WeatherLink com adding the Gateway adding Nodes to the Gateway and adding sensors to the Node EnviroMonitor App EnviroMonitor App Guides you throug...

Страница 9: ...n the cable Note The Gateway is powered by AC power with battery backup AC power is required it cannot be set up or run on batteries alone It is highly recommended that you install batteries to preven...

Страница 10: ...a message appears that an upgrade has been detected select Upgrade Upgrading can take several minutes Tip The blue LED flashes to show that the Gateway s BLE is on If it is not flashing press the rece...

Страница 11: ...tery in hardware kit Solar Panel Cable Mesh status LED Bluetooth status LED Solar Panel Jack Sensor Ports Mesh Antenna Lithium Battery Battery Compartment Door Door Tabs 1 4 Lock Washers 1 4 Hex Nuts...

Страница 12: ...sure the EnviroMonitor app has been installed on the smartphone you will be using to install the Node It will guide you through adding Nodes to the Gateway that has already been installed Power Up the...

Страница 13: ...mission Using the app you will be see this Node s serial number appear on the list for the Gateway You will know the Node has found its mesh parent a Gateway or another Node when you see the Bluetooth...

Страница 14: ...an RJ plug on its cable use the Davis RJ Adapter product number 6860 Or you can remove the plug and strip the wires Try not to strip the covering back so far that the bare wires can touch each other w...

Страница 15: ...Hemisphere or north in the Southern Hemisphere Tip Mounting the Node may be easier if done by two people Mounting On a Fence Post or Pole Mount the Node onto a fence post or a pole with an outside di...

Страница 16: ...d manage your data You can also use view and manage your data on your smartphone with the Mobilize app Find the app by searching for Davis Mobilize in the iOS App Store or Google Play Store You can al...

Страница 17: ...g connection Make sure the green sensor adapters in the Node are aligned properly and not offset Make sure the screws on the sensor adapters are very tight Make sure none of the sensor cables are pinc...

Страница 18: ...Radio LED The radio LED has timed out to save power Close then open the door to activate the radio LED Radio LED is solid amber for 3 seconds when powering up The Node is powering up Radio LED is blin...

Страница 19: ...ntact Davis Technical Support We ll be glad to help Online www davisinstruments com See the Weather Support section for copies of user manuals product specifications application notes software updates...

Страница 20: ...Power 2402 2480 MHz less than 1mW Certifications FCC CE IC Sensor Data internal sensors Barometric Pressure Resolution and Units 0 01 Hg 0 1 mm 0 1 hPa 0 1mb user selectable Range 16 00 to 32 50 Hg 4...