DAVIS 6152C Скачать руководство пользователя страница 2

2

 

Vantage Pro2

C o n s o l e

Console Operating Temperature . . . . . . . . . . . . . . . . . . .  +32° to +140°F (0° to +60°C)
Non-Operating (Storage) Temperature  . . . . . . . . . . . . . .  +14° to +158°F (-10° to +70°C)
Current Draw  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 mA average for console only, 10 mA average for both console and 

ISS

AC Power Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 VDC, 300 mA, regulated
Battery Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 C-cells
Battery Life (no AC power)  . . . . . . . . . . . . . . . . . . . . . . .  1 month (approximately)
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Modular RJ-11
Cable Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-conductor, 26 AWG
Cable Length, Console  . . . . . . . . . . . . . . . . . . . . . . . . . .  100’ (30 m) (included); 1000’ (300 m) (maximum recommended)
Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  UV-resistant ABS plastic
Console Display Type . . . . . . . . . . . . . . . . . . . . . . . . . . .  LCD Transflective
Display Backlight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  LEDs
Dimensions (console: length x width x height, display length x height)

Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9.63"  x  6.125"  x 1.625"  (245 mm x 156 mm x 41 mm)
Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5.94" x 3.375" (151 mm x 86 mm)

Weight (with batteries). . . . . . . . . . . . . . . . . . . . . . . . . . .  1.88 lbs. (.85 kg)

D a t a   D i s p l a y e d   o n   C o n s o l e

Data display categories are listed with General first, then in alphabetical order.

G e n e r a l

Historical Graph Data  . . . . . . . . . . . . . . . . . . . . . . . . . . .  Includes the past 24 values listed unless otherwise noted; all can be 

cleared and all totals reset

Daily Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Includes the earliest time of occurrence of highs and lows; period 

begins/ends at 12:00 am

Monthly Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Period begins/ends at 12:00 am on the first of the month
Yearly Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Period begins/ends at 12:00 am on the first of January unless 

otherwise noted

Current Display Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Current display data describes the current reading for each weather 

variable. In most cases, the variable lists the most recently updated 
reading or calculation. Some current variable displays can be 
adjusted so there is an offset for the reading.

Current Graph Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Current data appears in the right most column in the console graph 

and represents the latest value within the last period on the graph; 
totals can be set or reset. Display intervals vary. Examples include: 
Instant, 15-min., and Hourly Reading; Daily, Monthly, High and Low

Graph Time Interval  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1 min., 10 min., 15 min., 1 hour, 1 day, 1 month, 1 year (user-

selectable, availability depends upon variable selected)

Graph Time Span  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24 Int Current Interval (see Graph Intervals to determine time 

span)

Graph Variable Span (Vertical Scale)  . . . . . . . . . . . . . . .  Automatic (varies depending upon data range); Maximum and 

Minimum value in range appear in ticker

Alarm Indication  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Alarms sound for only 2 minutes (time alarm is always 1 minute) if 

operating on battery power. Alarm message is displayed in ticker as 
long as threshold is met or exceeded. Alarms can be silenced (but not 
cleared) by pressing the DONE key.

Update Interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Varies with sensor - see individual sensor specifications

B a r o m e t r i c   P r e s s u r e

Resolution and Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0.01" Hg, 0.1 mm Hg, 0.1 hPa/mb (user-selectable)
 Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16.00" to 32.50" Hg, 410 to 820 mm Hg, 540 to 1100 hPa/mb
Elevation Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  -999’ to +15,000’ (-600 m to 4570 m) (Note that console screen limits 

entry of lower elevation to -999’ when using feet as elevation unit.)

Содержание 6152C

Страница 1: ...re sensor readings Integrated Sensor Suite ISS Operating Temperature 40 to 150 F 40 to 65 C Non operating Temperature 40 to 158 F 40 to 70 C Current Draw 5 mA average at 4 to 6 VDC for ISS only 10 mA average for both console and ISS Connectors Sensor Modular RJ 11 Cable Type 4 conductor 26 AWG Cable Length Anemometer 40 12 m included 240 73 m maximum recommended Note Maximum displayable wind decre...

Страница 2: ...isplay data describes the current reading for each weather variable In most cases the variable lists the most recently updated reading or calculation Some current variable displays can be adjusted so there is an offset for the reading Current Graph Data Current data appears in the right most column in the console graph and represents the latest value within the last period on the graph totals can ...

Страница 3: ...le Accuracy 8 seconds month Adjustments Time Automatic Daylight Savings Time for users in North America and Europe that observe it in AUTO mode MANUAL setting available for all other areas Date Automatic Leap Year Alarms Once per day at set time when active Dewpoint calculated Resolution and Units 1 F or 1 C user selectable C is converted from F rounded to nearest 1 C Range 105 to 130 F 76 to 54 C...

Страница 4: ...h Historical Graph Data Hourly Calculations Daily Monthly Highs Alarm High Threshold from Instant Calculation Humidity Inside Relative Humidity sensor located in console Resolution and Units 1 Range 1 to 100 RH Accuracy 3 0 to 90 RH 4 90 to 100 RH Update Interval 1 minute Current Display Data Instant user adjustable offset available Current Graph Data Instant Hourly Reading Daily Monthly High and ...

Страница 5: ...ge for Rain Alarms 0 to 99 99 0 to 999 7 mm Rain Rate Resolution and Units 0 01 or 0 1mm user selectable at typical rates see Fig 2 and 3 Range 0 0 04 hr 1 mm hr to 96 hr 0 to 2438 mm hr Accuracy 5 for rates less than 5 per hour 127 mm hr Update Interval 20 to 24 seconds Calculation Method Measures time between successive tips of rain collector Elapsed time greater than 15 minutes or only one tip ...

Страница 6: ...able Current Graph Data Instant Daily Monthly Yearly High and Low Historical Graph Data Hourly Readings Daily Monthly Yearly Highs and Lows Alarms High and Low Thresholds from Instant Reading Temperature Humidity Sun Wind Index requires solar radiation sensor Resolution and Units 1 F or 1 C user selectable C is converted from F rounded to nearest 1 C Range 90 to 165 F 68 to 74 C Accuracy 4 F 2 C t...

Страница 7: ...cal Graph Data Hourly Daily and Monthly Lows Alarm Low Threshold from Instant Calculation Wind Direction Range 0 360 Display Resolution 16 points 22 5 on compass rose 1 in numeric display Accuracy 3 Update Interval 2 5 to 3 seconds Current Graph Data Instant Reading user adjustable 10 min Dominant Hourly Daily Monthly Dominant Historical Graph Data Past 6 10 min Dominants on compass rose only Hour...

Страница 8: ... 011698 00774 5 6162CUK 011698 00775 2 Figure 1 Temperature Accuracy Temperature Accuracy 0 0 1 0 2 0 3 0 4 0 5 0 40 20 0 20 40 60 80 100 120 140 Temperature F Temperature Accuracy 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 40 30 20 10 0 10 20 30 40 50 60 Temperature C Accuracy F Accuracy C Rain Rate Resolution Low Range Resolution in 10 0 1 00 0 10 0 01 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1...