DAVIS 6152C Скачать руководство пользователя страница 1

DS6152C, 6162C Rev. J, 2/13/13

1

Vantage Pro2

(510) 732-9229       FAX (510) 670-0589       [email protected]      www.davisnet.com

3465 Diablo Ave., Hayward, CA 94545-2778

3465 Diablo Ave., Hayward, CA 94545-2778  USA

®

  

t

 

t

  

 

t

 

6152C

6162C

Cabled Vantage Pro2™ 
& Vantage Pro2 Plus™ Stations

The Vantage Pro2

 (# 6152C) and Vantage Pro2

 Plus (# 6162C) cabled weather stations include two components: 

the Integrated Sensor Suite (ISS) and the console. The ISS contains the sensor interface module (SIM), rain collector, 
an anemometer, and a passive radiation shield. The Vantage Pro2 console provides the user interface, data display, 
and calculations. The Vantage Pro2 Plus weather station includes two additional sensors that are optional on the 
Vantage Pro2 and purchased separately: the UV Sensor and the Solar Radiation Sensor. The console and ISS are 
powered by an AC-power adapter connected to the console. Batteries can be installed in the console to provide a 
backup power supply. Use WeatherLink

®

 to let your weather station interface with a computer, log data, and upload 

weather information to the Internet. The 6152C and 6162C models rely on passive shielding to reduce solar-radiation 
induced temperature errors in the outside temperature sensor readings. 

I n t e g r a t e d   S e n s o r   S u i t e   ( I S S )

Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . .  -40° to +150°F (-40° to +65°C)
Non-operating Temperature  . . . . . . . . . . . . . . . . . . . . . .  -40° to +158°F (-40° to +70°C)
Current Draw. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 mA (average) at 4 to 6 VDC for ISS only. 10 mA average for both 

console and ISS

Connectors, Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Modular RJ-11
Cable Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-conductor, 26 AWG
Cable Length, Anemometer . . . . . . . . . . . . . . . . . . . . . . .  40’ (12 m) (included); 240’ (73 m) (maximum recommended)

Note: 

Maximum displayable wind decreases as the length of cable increases.  at 140’ (42 m) of cable, the maximum wind speed displayed is 135 mph (60 
m/s); at 240’ (73 m), the maximum wind speed displayed is 100 mph (34 m/s).

Wind Speed Sensor  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Solid state magnetic sensor
Wind Direction Sensor  . . . . . . . . . . . . . . . . . . . . . . . . . .  Wind vane with potentiometer
Rain Collector Type  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Tipping bucket, 0.01" per tip (0.2 mm with metric rain adapter), 33.2 in

2

 

(214 cm

2

) collection area

Temperature Sensor Type . . . . . . . . . . . . . . . . . . . . . . . .  PN Junction Silicon Diode
Relative Humidity Sensor Type . . . . . . . . . . . . . . . . . . . .  Film capacitor element
Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  UV-resistant ABS, ASA plastic
Sensor Inputs

RF Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  RC low-pass filter on each signal line

ISS Dimensions

Product #

Dimensions (Length x Width x Height)

Package Weight

6152C

11.0" x 9.3" x 14.0" 

(279 mm x 238 mm x 355 mm) 

5.7 lbs. (2.6 kg)

6162C

6.1 lbs. (2.8 kg)

N

S

W

E

N E

S E

N W

S W

C H IL L

W IN D

R A IN  R A

T E

in /h r

T E M P  O U T

H U M  IN

H U M  O U T

DA IL

Y  R A IN

in

T E M P  IN

in m b

B A R

O M E T E R

S TAT IO N   N O

.1

F

F

p m

F

M P H

L a s t  2 4h rs

h r

E ve ry  1

N

W

S

E

N

Содержание 6152C

Страница 1: ...re sensor readings Integrated Sensor Suite ISS Operating Temperature 40 to 150 F 40 to 65 C Non operating Temperature 40 to 158 F 40 to 70 C Current Draw 5 mA average at 4 to 6 VDC for ISS only 10 mA average for both console and ISS Connectors Sensor Modular RJ 11 Cable Type 4 conductor 26 AWG Cable Length Anemometer 40 12 m included 240 73 m maximum recommended Note Maximum displayable wind decre...

Страница 2: ...isplay data describes the current reading for each weather variable In most cases the variable lists the most recently updated reading or calculation Some current variable displays can be adjusted so there is an offset for the reading Current Graph Data Current data appears in the right most column in the console graph and represents the latest value within the last period on the graph totals can ...

Страница 3: ...le Accuracy 8 seconds month Adjustments Time Automatic Daylight Savings Time for users in North America and Europe that observe it in AUTO mode MANUAL setting available for all other areas Date Automatic Leap Year Alarms Once per day at set time when active Dewpoint calculated Resolution and Units 1 F or 1 C user selectable C is converted from F rounded to nearest 1 C Range 105 to 130 F 76 to 54 C...

Страница 4: ...h Historical Graph Data Hourly Calculations Daily Monthly Highs Alarm High Threshold from Instant Calculation Humidity Inside Relative Humidity sensor located in console Resolution and Units 1 Range 1 to 100 RH Accuracy 3 0 to 90 RH 4 90 to 100 RH Update Interval 1 minute Current Display Data Instant user adjustable offset available Current Graph Data Instant Hourly Reading Daily Monthly High and ...

Страница 5: ...ge for Rain Alarms 0 to 99 99 0 to 999 7 mm Rain Rate Resolution and Units 0 01 or 0 1mm user selectable at typical rates see Fig 2 and 3 Range 0 0 04 hr 1 mm hr to 96 hr 0 to 2438 mm hr Accuracy 5 for rates less than 5 per hour 127 mm hr Update Interval 20 to 24 seconds Calculation Method Measures time between successive tips of rain collector Elapsed time greater than 15 minutes or only one tip ...

Страница 6: ...able Current Graph Data Instant Daily Monthly Yearly High and Low Historical Graph Data Hourly Readings Daily Monthly Yearly Highs and Lows Alarms High and Low Thresholds from Instant Reading Temperature Humidity Sun Wind Index requires solar radiation sensor Resolution and Units 1 F or 1 C user selectable C is converted from F rounded to nearest 1 C Range 90 to 165 F 68 to 74 C Accuracy 4 F 2 C t...

Страница 7: ...cal Graph Data Hourly Daily and Monthly Lows Alarm Low Threshold from Instant Calculation Wind Direction Range 0 360 Display Resolution 16 points 22 5 on compass rose 1 in numeric display Accuracy 3 Update Interval 2 5 to 3 seconds Current Graph Data Instant Reading user adjustable 10 min Dominant Hourly Daily Monthly Dominant Historical Graph Data Past 6 10 min Dominants on compass rose only Hour...

Страница 8: ... 011698 00774 5 6162CUK 011698 00775 2 Figure 1 Temperature Accuracy Temperature Accuracy 0 0 1 0 2 0 3 0 4 0 5 0 40 20 0 20 40 60 80 100 120 140 Temperature F Temperature Accuracy 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 40 30 20 10 0 10 20 30 40 50 60 Temperature C Accuracy F Accuracy C Rain Rate Resolution Low Range Resolution in 10 0 1 00 0 10 0 01 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1...

Отзывы: