2

Hardware Installation

Standard 4-Conductor Extension Cable

 — Use one 40’ (12 m) extension 

cable (#7876-040) to extend the distance between your station and the 
computer. (48’ (14.4 m) maximum)

Hardware Installation

You can connect a computer directly to your weather station using the 
WeatherLink data logger (local connection), or you can connect a computer to 
a remote weather station using a phone modem (remote connection). 
Requirements and installation for each type of connection differ, and are 
explained separately below.

Hardware Requirements

The hardware requirements for local and remote connections are listed below.

Local Connection Hardware Requirements

In addition to the provided hardware, the following are required for a direct 
connection.
• Macintosh computer running OS X v10.01 or newer with at least 5 MB of 

free disk space
The amount of space necessary for the data files depends on the archive 
interval. Database files containing data stored at a 30 minute archive inter-
val require approximately 36K of disk space per month of data. The file 
size changes in a linear fashion depending on the archive interval. For 
example, data stored at a 1–minute interval requires approximately 1 MB/
month while the data stored at a 2–hour interval requires approximately 
9K/month.

• A serial port adapter connected to a Macintosh USB port. 

Remote Connection Hardware Requirements

In addition to the provided hardware and the computer equipment listed above, 
the following hardware is required for a phone modem connection.
• One external modem to connect to the data logger at the remote site.
• One internal or external modem connected to your Macintosh computer
• Modems must be Hayes

®

–compatible and able to send data at 1200 or 

2400 baud for use with a Monitor II, Wizard II, or Perception II weather 
station.

Telephone Modem Adapter

 — The Telephone Modem Adapter is 

specially wired to provide the connection between the data logger and the 
modem. 

• Use a #7870 adapter with Wizard III, Monitor II, and Perception 

stations.

Содержание WeatherLink

Страница 1: ......

Страница 2: ...esidential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio c...

Страница 3: ...des 8 2 4 m cable to link your station to your com puter 9 pin DIN connector WeatherLink software CD ROM Required Accessories You will need to install a third party serial port adapter on your Macinto...

Страница 4: ...interval Database files containing data stored at a 30 minute archive inter val require approximately 36K of disk space per month of data The file size changes in a linear fashion depending on the ar...

Страница 5: ...ing power will cause these stored weather values to be erased Use WeatherLink to re enter these values as well as the time and date after restoring power to the console 2 Remove the mounting base from...

Страница 6: ...or to the serial port adapter 12 Connect the long data logger cable to the DIN connector The cable connecting the data logger to the computer is 8 2 4 m long If you need to place the station console m...

Страница 7: ...1200 baud change the setting before connecting the data logger to the console 6 Connect the short data logger cable to the cable jack marked Weather Link on the bottom of your weather station console...

Страница 8: ...Phone Modem Connections If you indicate a phone modem connection when setting up your station the software automatically dials the station whenever you initiate a program action that requires the soft...

Страница 9: ...s data base which means naming the station configuring the software to work with that station and with your computer hardware and setting station values such as time barometric pressure total rainfall...

Страница 10: ...ion Set the station s rainfall calibration number Enter Year to Date Rainfall Set the rainfall amount on the station and on the software You must enter this information from the software if you want y...

Страница 11: ...eep will be for the data logger if installed and the third beep is for the display If you do not hear one or more of these beeps contact Technical Support see Contacting Davis Technical Support on pag...

Страница 12: ...of the window select the port you want to test If you are using a Keyspan USB Twin Serial adapter or a similar USB to serial port adapter between your weather station and your Macintosh the port show...

Страница 13: ...23 Using the record editor to change the record in one day does not change the record in the other day Note Do not delete the duplicate midnight records it may affect your rain database or NOAA month...

Страница 14: ...d the correct station before downloading Your data logger may be not be operating properly If this is the case you can restore proper operation by repowering the data logger 1 Remove power from the da...

Страница 15: ...echnical Support Most questions can be answered on the phone Note Sorry we are unable to accept collect calls Phone Support 510 732 7814 Monday Friday 7 00 a m 5 30 p m Pacific Time 510 670 0589 Techn...

Страница 16: ...harts Ctrl T Set Time Ctrl U Select Units Ctrl V View Download Log Ctrl W Browse Database Ctrl X Auto Fax Settings Ctrl Y View Summary Ctrl Z Close Window F1 Context Sensitive Help F2 Sunrise Sunset R...

Отзывы: