background image

 

Page 8

Rain Collector II

 

Choosing a Location for the Rain Collector

 

Keep the following in mind when choosing a location for your rain collector.

 

 

You must mount the Rain Collector II on a level surface.

 

To make sure the surface is level, use a bubble level or pour water into 
the T-shaped leveling trough in the base and observe the surface of the 
water. Users of the industrial rain collector may use the bubble level 
attached to the base to insure that the mounting surface is level.

 

 

Be sure there is an unobstructed path for water runoff from the drain screens.

 

 

The Rain Collector II contains a magnet-operated switch which may not operate 
correctly if you mount the rain collector on or near any object which attracts a 
magnet.

 

To install the rain collector on a sheet metal roof, insulate the unit by 
making a platform out of wood. Mount the base of the rain collector at 
least 1"(4 cm) away from any steel or iron surface and make sure the reed 
switch is at least 1" (4 cm) away from any steel or iron objects (e.g., nails).

 

 

Choose a location which is easily accessible for normal cleaning and is distant 
from trees or other sources of heavy pollen or debris.

 

Installing the Rain Collector II

 

1. If you have not already done so, separate the cone from the base.

2. If necessary, disconnect the rain collector cable from the junction box/SIM.

3. Locate a suitable mounting surface, using the guidelines above.

4. Place the base on the mounting surface and mark the location of the four holes (the 

base has eight to choose from) you will use to secure the base.

5. Make pilot holes using a 3/32" (2 mm) drill bit. You should make the pilot holes about 

1/2" (12 mm) deep.

Содержание Rain Collector

Страница 1: ...ying rainfall on the Weather Wizard II S Weather Wiz ard III and Weather Monitor II are also included in this manual Instructions for displaying rainfall on the GroWeather Health EnviroMonitor and Ene...

Страница 2: ...or many of which are referenced in this manual Note that the industrial versions of the rain collector also include a terminal block to which the rain collector cable is connected and a bubble level t...

Страница 3: ...ress and hold the RAIN button until CAL appears on the display Consult the station manual if necessary for further instructions Be aware that the console will revert to its default calibration i e inc...

Страница 4: ...en sor interface module SIM Consult your station manual or system installation manual 4 Press the appropriate key on your console as necessary to display daily rainfall Press UNITS if necessary to dis...

Страница 5: ...ury or loss resulting from the installation or use of the Rain Collector II Follow the instructions in this section to install your rain collector Make sure you read see Choosing a Location for the Ra...

Страница 6: ...e illustration below shows a typical standard rain collector installation for the GroWeather Energy EnviroMonitor or the Health EnviroMonitor The rain collector cable attaches to connector S1 on the s...

Страница 7: ...tion The illustration below shows a typical industrial rain collector installation for the GroWeather Energy EnviroMonitor or the Health EnviroMonitor The rain collector cable attaches to connector S1...

Страница 8: ...magnet To install the rain collector on a sheet metal roof insulate the unit by making a platform out of wood Mount the base of the rain collector at least 1 4 cm away from any steel or iron surface...

Страница 9: ...g the cone clockwise until the latches lock into place As you reattach the cone make sure to run the cable to the cable slot in the base or the cone will not fit snugly against the base 10 Place the d...

Страница 10: ...isted Pair Extension Cables from Davis You may splice the extension cable to the existing rain col lector cable or you may remove the rain collector cable from the termi nal block and the cable clamp...

Страница 11: ...es the bucket to tip more times i e give a larger count for a given amount of water ADJUSTMENT GUIDE Note Modify both adjustment screws by the same amount MAINTAINING THE RAIN COLLECTOR II For greates...

Страница 12: ...o display daily rainfall press RAIN The daily rainfall and the word RAIN appear on the display DAILY RAINFALL 2 To display total rainfall press RAIN again The total rainfall and the words RAIN and TOT...

Страница 13: ...ll flash several times and then the weather station clears rain fall DAILY RAINFALL CLEARED Note Performing a total clear on the weather station does not clear rainfall To Set Total Rainfall You may e...

Страница 14: ...amounts in 0 2 mm increments but displays amounts rounded to the nearest whole millimeter Note Keep in mind when testing the rain collector with older weather stations that the display adds 1 mm for e...

Страница 15: ...ll check that you have cut the cable tie that holds it in place during shipping Make sure the console is calibrated correctly by setting the console to your unit preference before viewing or changing...

Страница 16: ...avis Instruments Part Number 7395 024 Rain Collector Standard Industrial Rev C Manual 7 7 99 This product complies with the essential protection requirements of the EC EMC Directive 89 336 EC Davis In...

Отзывы: