12
Features and Specifications
© Travis Industries
4150126
100-01418
Dimensions – Left Side Corner Configuration
NOTE
: The master module is always on the end that has a steel end.
(a)
Air intake
– See table below for quantity - Location determined by fireplace length (see “Air Intake Duct
Location” on page 54 for details).
(b)
Exhaust
– Uses 10” or 8” Diameter B-Vent (determined by power exhaust type). Centered on fireplace.
(c)
Gas Control Valve
– Located to the front of the master module (the front of the fireplace is determined by gas
control valve location).
(d)
Electrical Junction Box
– On master module (location determined at time of order – can be relocated),
includes 120v input, exhaust vent power/harness, on-off LED harness.
(e)
Gas Inlet
– On master module (NOTE: the gas inlet is always located along the front edge, even if master
module is on the left side).
Horizontal Dimensions & Specifications
Version
Width (x)
Exhaust Loc. (y)
Air Intakes Power Exhaust
BTUs
78” Right or Left Side
79” (2007mm)
19” (483mm)
2
Low Volume
87,000
90” Right or Left Side
91” (2312mm)
25” (635mm)
3
High Volume
101,500
102” Right or Left Side 103” (2617mm) 25” (635mm)
3
High Volume
116,000
114” Right or Left Side 115” (2921mm) 31” (788mm)
4
High Volume
130,500
126” Right or Left Side 127” (3226mm) 31” (788mm)
4
High Volume
145,000
20"
508mm
5.75"
(147mm)
x
a
y
b
a
Master
Module
Secondary
Module
c
Version
Length
d
e
Front
avant
Right
droit
Rear
arrie're
Left
a' gauche
12.5"
318mm
12" (305mm)
20" (508mm)
30" (762mm)
36" (915mm)
12" Glass
42.625" (1083mm)
20" Glass
50.625" (1286mm)
30" Glass
60.625"
(1540mm)
36" Glass
66.625 (1693mm)