GENERAL SAFETy RULES 

!

WARNING

  Read all instructions. Failure to follow all instructions listed 

below may result in hazardous radiation exposure, electric 

shock, fire and/or serious injury. 
If glass light house breaks when dropped, contact customer service 

immediately. 

Broken glass can cause laceration hazard and unit to 

lose its IP rating. 

IEC 60825-1:2007-03 

< 1 mW, 635 nm

DO NOT direct the laser beam at persons or animals and do not 

stare into the laser beam yourself. This tool produces laser class 2 

laser radiation and complies with 21 CFR 1040.10 and 1040.11 

except for deviations pursuant to Laser Notice No. 50, dated June 

24, 2007. This can lead to persons being blinded.

DO NOT remove or deface any warning or caution labels.  

Removing labels increases the risk of exposure to laser radiation.

Use of controls or adjustments or performance of procedures other than those 

specified in this manual, may result in hazardous radiation exposure.
ALWAyS make sure that any bystanders in the vicinity of use are made aware 

of the dangers of looking directly into the laser tool.
DO NOT place the laser tool in a position that may cause anyone to stare into 

the laser beam intentionally or unintentionally. 

Serious eye injury could result.

ALWAyS position the laser tool securely. 

Damage to the laser tool and/or 

serious injury to the user could result if the laser tool falls. 

ALWAyS use only the accessories that are recommended by the manufacturer 

of your laser tool.

 Use of accessories that have been designed for use with 

other laser tools could result in serious injury or unsatisfactory performance.

DO NOT use this laser tool for any purpose other than those outlined in this 

manual.

 This could result in serious injury or unsatisfactory performance.

DO NOT leave the laser tool “ON” unattended in any operating mode.
DO NOT disassemble the laser tool.

 There are no user serviceable parts inside. 

Do not modify the product in any way. Modifying the laser tool may result in 

hazardous laser radiation exposure.

Содержание 4200H

Страница 1: ...us com 4200H 4200HV Rotary Laser Owner s Guide 4200H FOR CUSTOMER SERVICE PARTS AND REPAIR CALL 765 581 4097 IMPORTANT IMPORTANT IMPORTANTE Read Before Using Lire avant usage Leer antes de usar 180 10 45 90 RPM 4200HV ...

Страница 2: ...xtremely rugged field use Like all precision instruments however they should be treated with reasonable care to prolong life and accuracy All instruments are adjusted when they are shipped from the factory It is the customer s responsibility to check and to ensure instruments are adjusted prior to using David White is not responsible for errors caused by instruments that are out of adjustment Cont...

Страница 3: ... 3 180 10 45 90 RPM 4200HV 8 7 180 10 45 90 RPM 4200HV f d e h g b a c 1 2 3 4 6 5 ...

Страница 4: ... 4 4200H 4200H 1 2 3 4 6 5 d b a c ...

Страница 5: ...may result in hazardous radiation exposure ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool DO NOT place the laser tool in a position that may cause anyone to stare into the laser beam intentionally or unintentionally Serious eye injury could result ALWAYS position the laser tool securely Damage to the laser tool and ...

Страница 6: ...ery chemistries Dispose of or recycle batteries per local code DO NOT dispose of batteries in fire Keep batteries out of reach of children Personal safety Stay alert watch what you are doing and use common sense when operating a tool Do not use a tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a tool may result in serious perso...

Страница 7: ...ch does not turn it on and off Any tool that cannot be controlled with the switch is dangerous and must be repaired Store idle tool out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate the tool Tools are dangerous in the hands of untrained users Maintain tools Check for misalignment or binding of moving parts breakage of parts and any othe...

Страница 8: ... 3h Clockwise Beam Positioning Button 4 Charger Port 5 5 8 11 Tripod Mount Down Plumb Beam 4200HV 6 Carrying Handle 7 Reception Sensors for Remote Control 8 Window for Plumb Beam Technical Data Description 4200H 4200HV Accuracy Horizontal leveling 1 8 in at 100 ft 3mm at 30m 1 8 in at 100 ft 3mm at 30m Accuracy Vertical Laydown n a 1 8 in at 100 ft 3mm at 30m Working Range diameter without Laser D...

Страница 9: ...es pack from the tool when not using it for extended periods When storing for extended periods the batteries can corrode and discharge themselves Un screw the bolt at the bottom of instrument base Remove the battery pack Use either alkaline battery or Ni Mh battery pack When inserting alkaline batteries pay attention to the correct polarity according to the representation on the inside of the batt...

Страница 10: ...ot subject the instrument to extreme temperatures or variations in temperature As an example do not leave it in vehicles for long time In case of large variations in temperature allow the instrument to adjust to the ambient temperature before putting it into operation In case of extreme temperatures or variations in temperature the accuracy of the instrument can be impaired Avoid heavy impact to o...

Страница 11: ...0HV Only The Variable Rotation Speed Mode keypad 3e will give you the option of increasing or decreasing the speed of the rotating laser Repeatedly pressing the 180 10 45 90 RPM keypad will adjust the speed from 600 300 150 and 0 RPM Scanning or Sweeping 4200HV Only The Scanning Mode 3f creates a shorter brighter laser chalk line that can be used for leveling or plumbing This feature can also be u...

Страница 12: ... slope is set at the desired position To return to automatic Self Leveling Mode press the Manual Automatic 3b keypad again Allow time for the instrument to self level Smart H I Alert System ADS Enable to the ADS system 3c to alert user when laser has been disturbed Press the ADS button 180 10 45 90 RPM to activate When the LED is blinking slowly the laser is in H I Alert mode When the light is bli...

Страница 13: ...ting your work A free measuring distance of 165 ft 50m on a firm surface is required for the check A reversal measurement must be carried out over both axes X and Y each positive and negative 4 complete measurements Mount the instrument in the horizontal position onto a tripod or place it on a firm and level surface near wall Switch the instrument on Position the X axis to aim to a wall or target ...

Страница 14: ...strument for the measured axis The value of D deviation in either axis should be less than 5 16 in 8mm If the instrument should exceed the maximum deviation in anyone of the measuring procedures have it checked at a SitePro after sales service agent Checking the Vertical Alignment 4200HV Only A free measuring distance of 100 ft 30m on a firm surface between two walls or targets A and B is required...

Страница 15: ...ctly on point H2 of wall B Rotate the instrument by 180 without changing the height allow it to level and mark the center point of the laser beam on wall A point H3 The mark of point H3 should be marked in such a way that it is as vertical as possible above or below of point H1 100 ft 30 m 1 5 ft 0 5 m 100 ft 30 m 1 5 ft 0 5 m A H1 H2 B 100 ft 30 m 1 5 ft 0 5 m A H1 D H3 H2 B 100 ft 30 m 1 5 ft 0 ...

Страница 16: ...ures of the 4200HV can be controlled using the remote Requires 2 AA Alkaline batteries RC420 remote control LD20 Detector The detector aids in locating and targeting a visible or invisible beam emitted by a rotary laser instrument perfect for use in outdoor conditions where sunlight and distance may make locating the beam more difficult The laser detector includes a rod clamp which allows to mount...

Страница 17: ...e battery low indicator g will display Remove the battery when not using it for extended periods When storing for extended periods the battery can corrode and discharge 3f Audio signal indicator 3g Battery low indicator 4 Reception area for the laser beam 5 Button for adjustment of measuring accuracy 6 Spirit level 7 Speaker 8 Audio signal button 9 Locking screw for leveling rod 10 Magnetic mounts...

Страница 18: ...d soft cloth Do not use any cleaning agents or solvents Regularly clean the surfaces at the exit opening of the laser in particular and pay attention to any fluff of fibers If the tool should fail despite the care taken in manufacturing and testing procedures repair should be carried out by an authorized after sales service center for Dave White s SitePro instruments In all correspondence and spar...

Страница 19: ...NE YEAR FROM DATE OF PURCHASE SOME STATES IN THE U S AND SOME CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LIABILITY FOR LOSS OF PROFITS ARISING FROM THE SALE OR USE OF THIS PRODUCT SOME STATES IN THE U S AND S...

Страница 20: ...42348D4200 09 15 Printed in China Dave White s SitePro 7619 S 1150 E Otterbein IN 47970 Tel 1 765 581 4097 ...

Отзывы: