Mounting the FD-777A 

The FD-777A is designed to be surface mounted using the 
metal wall mounting plate within the box. Mounting height 
can vary depending on requirements. A suggested range is 
typically between 50 to 55 inches from the bottom of the 
ground.  

Fix the wall mount bracket on the wall using the wall 
mounting screws and secure the FD-777A on the mounting 
plate using the supplied Allen-Key screw. 

 

  

 

 

 

Communication Port Detail

 

 

 

 

 

 

 

 

 

 

 

 

Use the terminal block found in packaging to 
connect proper wires to the port at the back of the 
FD-777A reader. Securely tighten up the electrical 
wires on the block before plugin to the port.  

 

Pin 

Suggest Wire 

Color 

Description 

GND 

Black 

Ground  

12V 

Red 

12V DC  

GND 

Black 

Ground 

KEY 

Blue 

Exit Button 

NC 

Orange 

Fail-Open 

COM 

Purple 

Lock Common 

NO 

Yellow 

Fail-Close 

GND 

Black 

Ground 

D0 

Green 

Wiegand Data 0 

D1 

White 

Wiegand Data 1 

50 to 55 Inches 

Содержание FD-777

Страница 1: ...Page 1 FD 777 FACIAL RECOGNITION INSTALLATION MANUAL For Access Control or Time Attendance ...

Страница 2: ...ntact your service provider installer Parameter Specification Power Votage 12V 3A Environment Indoor Tempature Tolerance 22 to 130 F Output Format NO NC Wiegand 26 Communication TCP IP USB Drive Motion Detect Infrared Capture Time 0 4 Sec Capture Distance 15 20 Inch Camera Type 2x 1 3 Mega Pixels Capture Type 3D Image Installation Mode Standalone Controller Note For additional information about in...

Страница 3: ...and reader mode Below is a brief explanation of each mode Refer to the programming section for details about selecting each mode Standalone Mode By default the FD 777A is programmed for Standalone Mode In this mode all the users and other programming options are maintained within the reader and no additional controller is required The lock and all other inputs and outputs are connected directly to...

Страница 4: ...ure the FD 777A on the mounting plate using the supplied Allen Key screw Communication Port Detail Use the terminal block found in packaging to connect proper wires to the port at the back of the FD 777A reader Securely tighten up the electrical wires on the block before plugin to the port Pin Suggest Wire Color Description GND Black Ground 12V Red 12V DC GND Black Ground KEY Blue Exit Button NC O...

Страница 5: ...Page 5 Wiring Sample Standalone Mode Magnetic Lock Wiring Sample Standalone Mode Strike Lock ...

Страница 6: ...Page 6 Wiring Sample Wiegand Reader Mode Wiring Sample Open Button Note This is only for using standalone mode If using Wiegand reader mode open button will be connect to the third party controller ...

Отзывы: