background image

 

 

 

 

7

 

of

 

11

 

 

19541P

39

 

(02

11)

 

6.

 

A

 

voice

 

alert

 

will

 

indicate

 

that

 

the

 

connection

 

has

 

been

 

deleted.

 

 

When

 

this

 

procedure

 

is

 

complete,

 

the

 

belt

 

station

 

will

 

not

 

automatically

 

connect

 

to

 

a

 

controller/gateway

 

and

 

must

 

be

 

linked

 

again.

 

 

 

Содержание U9910-BSW

Страница 1: ...19541P 39 02 11 2011 DAVID CLARK COMPANY INCORPORATED USER MANUAL Wireless Belt Station U9910 BSW U9910 BSW EU P N 40992G 01 P N 40992G 03...

Страница 2: ......

Страница 3: ...damage If damage is apparent immediately file a claim with the carrier and notify your David Clark product supplier ELECTRICAL HAZARD Disconnect electrical power when making any internal adjustments...

Страница 4: ...quired per system Up to four belt stations can be connected to one controller gateway Model U9910 BSW Wireless Belt Station P N 40992G 01 VOX Adjust Headset Connector Power Button Status LED Battery C...

Страница 5: ...to four of those six at one time Tip Once linked the devices will not need to be linked again unless they are purged see Purging Units may be special ordered that do not have persistent links S St ta...

Страница 6: ...and then turn off The belt station is now powered down Auto Shut off Additionally the belt station will automatically power down if it is disconnected from its gateway controller for more than 30 min...

Страница 7: ...knob fully counter clockwise CCW Mic is hot VOX knob in between full CW and full CCW VOX enabled VOX Adjustment Procedure 1 Ensure that the belt station is linked with a controller or gateway LED flas...

Страница 8: ...T button allows the user to activate additional functionality such as to speak over a two way radio or to an aircraft intercom PTT will also override the VOX setting see VOX For more information see t...

Страница 9: ...541P 39 02 11 6 A voice alert will indicate that the connection has been deleted When this procedure is complete the belt station will not automatically connect to a controller gateway and must be lin...

Страница 10: ...t Battery with Contacts Down Lift Door Figure 4 Battery Insertion Removal T Tr ro ou ub bl le es sh ho oo ot ti in ng g Table 3 Troubleshooting Problem Solution Controller will not turn on Review Powe...

Страница 11: ...ic ca at ti io on ns s Frequency Range 1920 MHz 1930 MHz U S and Canada 1880 MHz 1900 MHz EU Average RF Power Output 4 mW 100mW peak U S and Canada 10 mW 250 mW peak EU Range 300 ft 100m line of sigh...

Страница 12: ...gton D C 20402 In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in i...

Страница 13: ...ment known as the Specific Absorption Rate or SAR Tests for SAR are conducted using standardized methods with the product transmitting at its highest certified power level in all used frequency bands...

Отзывы: