background image

A good quality non-return valve must be installed 
in the pressure pump outlet pipework before the 
hot water service.  Failure to install this non-return 
valve may result in pump damage.  Such damage 
is not covered by guarantee.

Connection of Mains Scheme or Town Wa-
ter Supply to either Suction or Discharge of 
Pumps & Pressure Systems

Most Water Supply Authorities have strict regu-
lations regarding direct connection of pumps to 
mains water supplies.  In most cases an isolating 
tank is required between mains supply and pump.  Davey also recommend this 
method.  Directly applied mains pressure can exceed pump operating pressure 
and damage pump.

Davey Water Products 
Pty Ltd can not accept 
responsibility for loss or 
damage resulting from 
incorrect or unauthorised 
installations.

Connection to your Water Source

BELOW GROUND WATER SOURCES

Whenever the installation position of the pump is higher than 1m (3.3ft) above 
the lowest water level, a foot valve must be used on the end of the suction pipe 
as illustrated in (C) below.  Ensure that the foot valve is at least 

1

/

2

 metre below 

minimum water level.

SPEAR POINT INSTALLATIONS

When a Dynajet

®

 is installed on a spear or well point, a check valve must be 

fitted immediately on top of the spear point itself, as shown in (D) above.  

DO 

NOT INSTALL THE CHECK VALVE AT THE PUMP OR AT THE TOP OF THE 
WELL.  DO NOT RUN THE PUMP WITHOUT WATER.
NOTE: Be certain to select the spear point to suit the well conditions and
 

regulate the flow rate from the pump accordingly.

SPEAR SIZE 

MESH 

APPROX. MAX. CAPACITY OF SPEAR 

POINT

1

1

/

4

” (32mm) 

60 

15 - 23 1/min or 200 - 300 gal/hr

1

1

/

2

” (38mm) 

60 

23 - 38 1/min or 300 - 500 gal/hr

2” (50mm) 

60 

38 - 75 1/min or 500 - 1000 gal/hr

 

 

WARNING: Some insects, such as small ants, find electrical devices

 

attractive for various reasons.  If your pump enclosure is susceptible

 

to insect infestation you should implement a suitable pest control plan.

Choosing a Site

Choose a site with a firm base and as close 
to the water source as possible with correct 
power supply. Make sure your pressure 
system is always connected to an adequate, 
reliable source of clean water.

Housing your Davey Pressure System

To protect your pressure system from the weather, 
make sure the pump house is both water proof, 
frost free and has adequate ventilation.  The pump 
should be horizontally mounted on a firm base 
allowing for  drainage, to avoid damage to flooring 
etc., that over time may occur from leaking pipe 
joints or pump seals. Do not mount the pump 
vertically.

Pipe Connections

For best performance use P.V.C. or polythene pipes at least the same 
diameter as the pump’s inlet and delivery outlet openings. Larger diameter 
pipe may be used to minimise resistance to flow when pumping longer 
distances.

Use unions at pipe connections to enable easy removal and servicing. Use 
sufficient tape to ensure airtight seal and hand tighten only. To prevent strain 
on pump threads always support heavy inlet and outlet pipes. If there is a 
likelihood the water supply may contain solid particles such as pieces of plant 

or vegetable matter, a suction strainer 
should be installed before the pump to 
avoid blocking of the pump. Lay suction 
pipe at a constant gradient to avoid 
air pockets which may reduce pump 
efficiency.

Where to use Check Valves and Foot Valves

Installations with a suction lift over 1m require 
a good quality foot valve to avoid loss of prime.  
In this case, the poppet valve inside the pump 
should be removed.  Installations with flooded 
suction require a gate valve so water supply can 
be turned off for pump removal and servicing.

Prior to using this pump you must ensure that:

•  The pump is installed in a safe and dry environment

•  The pump enclosure has adequate drainage in the event of leakage

•  Any transport plugs are removed

•  The pipe-work is correctly sealed and supported

•  The pump is primed correctly

•  The power supply is correctly connected

•  All steps have been taken for safe operation

Appropriate details for all of these items are contained in the following Installation and 

Operating Instructions.  Read these in their entirety before switching on this pump.  If you 

are uncertain as to any of these Installation and Operating Instructions please contact 

your Davey dealer or the appropriate Davey office as listed on the back of this document.

Congratulations on your purchase of a high quality, Australian built Davey pressure 

pump. All components have been designed and manufactured to give trouble free, 

reliable operation.

XJ Ultra / XJ70P / XJ90P

1.  Pressure tank

 

(supplied separately)

2.  Pressure switch

3.  Delivery outlet (1”F)

4.  Suction inlet

 

(XJ Ultra = 1”F)

 

(XJ70P & XJ90P = 1

1

/

4

”F)

5.  Pump body

6.  Motor

XJ50 / XJ70 / XJ90

Are the same as above

less items 1 & 2.

Note: 

 Your XJ Ultra, XJ70P & 

XJ90P pump is designed to oper-
ate as an automatic pressure sys-
tem when used in conjunction with 
a pressure tank such as a Davey 
“Supercell 18C” tank (illustrated).  
The tank, supplied separately, 
needs to be fitted to the delivery 
outlet prior to operating.

Assembly

Attach pressure switch (2) 
to the delivery outlet tee (3) 
by hand tightening the pres-
sure switch union nut (ensure 
sealing oring is in place).
Screw pressure tank (1) onto 
delivery outlet.

 

Power Connection

 

Connect lead to power supply designated on pump label, do not use 

long extension leads as they cause substantial voltage drop, poor 

pump performance and may cause motor overload.

Before installing your new pump, please read all instructions carefully as failures caused 
by  incorrect  installation  or  operation  are  not  covered  by  the  guarantee.  Your  Dynajet®  
XJ pump is designed to handle clean water. It should not be used for any other purpose 
without specific referral to Davey.  The use of the pump to handle flammable, corrosive 
and other materials of a hazardous nature is specifically excluded.

Do not use this pump to pump flammable fluids, such as petrol or 

diesel fuels.

Do not use pipe thread sealing compounds on any part of this pump. 

ONLY use Teflon sealing tape.

NOTE: Suction leaks are the

largest cause of poor pump

performance and are difficult

to detect.  Ensure all

connections are completely

sealed using thread tape only. 

IMPORTANT

For Automatic Pressure Pumps Installed with a Mains Pressure Hot

Water System.

Abrasive Materials

The pumping of abrasive materials will cause damage to the

pressure system which will then not be covered by the guarantee.

Spear point flow capacities vary considerably.  Check with the supplier

to ensure the pump and spear point are correctly matched.