background image

AUSTRALIA
Customer Service Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 232 839

Fax: 

1300 369 119

Email: [email protected]

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND
Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

0800 654 333

Fax: 

0800 654 334

Email: [email protected]

Website: daveynz.co.nz

® Davey is a registered trademark of Davey Water Products Pty Ltd.  © Davey Water Products Pty Ltd 2017.

Davey Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any 

malfunction within two years of the date of original purchase due to faulty materials or 

manufacture, Davey will at 

our option repair or replace it for you free of charge, subject to the conditions below.
Should you experience any difficulties with your Davey product, we suggest in the first instance 

that you contact the Davey Dealer from which you purchased the Davey product. Alternatively 

you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New 

Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim, 

Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on 

how to have your Davey product repaired, obtain a replacement or a refund.
Your Davey Two Year Guarantee naturally does not cover normal wear or tear, replacement of 

product consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting 

from misuse or negligent handling, improper use for which the product was not designed or 

advertised, failure to properly follow the provided installation and operating instructions, failure 

to carry out maintenance, corrosive or abrasive water or other liquid, lightning or high voltage 

spikes, or unauthorised persons attempting repairs.  Where applicable, your Davey product 

must only be connected to the voltage shown on the nameplate.
Your Davey Two Year Guarantee does not cover freight or any other costs incurred in making a 

claim. Please retain your receipt as proof of purchase; you MUST provide evidence of the date 

of original purchase when claiming under the Davey Two Year Guarantee. 
Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, 

damage or injury of any kind whatsoever arising directly or indirectly from Davey products. 

This limitation does not apply to any liability of Davey for failure to comply with a consumer 

guarantee applicable to your Davey product under the Australian or New Zealand legislation 

and does not affect any rights or remedies that may be available to you under the Australian or 

New Zealand Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation 

for any other reasonably foreseeable loss or damage. You are also entitled to have the goods 

repaired or replaced if the goods fail to be of acceptable quality and the failure does not 

amount to a major failure.
Should your Davey product require repair or service after the guarantee period; contact your 

nearest Davey Dealer or phone the Davey Customer Service Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:

*  Installation and operating instructions are included with the product when purchased new. 

They may also be found on our website.

P/N 402215-1

Содержание Weekender XP

Страница 1: ...Davey Weekender XP Home Pressure Systems Please pass these instructions on to the operator of this equipment NOTE Prior to installation remove the inlet and outlet pipe transport plugs associated seals from the suction and or discharge ports ...

Страница 2: ... contact your Davey dealer or the appropriate Davey office as listed on the back of this document Congratulations on your purchase of a high quality Australian built Davey pressure pump All components have been designed and manufactured to give trouble free reliable operation Before installing your new system please read all instructions carefully as failures caused by incorrect installation or op...

Страница 3: ...ow when pumping longer distances Power Connection Connect lead to power supply designated on pump label do not use long extension leads as they cause substantial voltage drop poor pump performance and may cause motor overload Use unions at pipe connections to enable easy removal and servicing Use sufficient tape to ensure airtight seal and hand tighten only To prevent strain on pump threads always...

Страница 4: ...off pump and unplug it from power point 2 Remove pressure switch cap 3 Turn Adjusting screw A 1 2 turn anticlockwise 4 Replace cap and switch on pump 5 If pump cuts out repeat steps 1 2 and 3 Adjustment is now complete 6 If pump does not cut out after step 4 repeat steps 1 to 5 IMPORTANT For Automatic Pressure Pumps Installed with a Mains Pressure Hot Water System Use gate valves for flooded sucti...

Страница 5: ...s or damage resulting from incorrect or unauthorised installations When used with a Float Valve Where your pressure system is required to discharge through float valves filling tanks the possibility of excessive cycling may occur This can be overcome by fitting a larger Davey Supercell pressure tank in place of the Supercell tank supplied Priming and Operation 1 Fill pump and suction line On 3 Ens...

Страница 6: ...and pump body not filled with water 2 Air leaks in suction lines or suction pipe not under water 3 Air trapped in suction lines also possible with flooded suction due to uneven rise in piping eliminate humps and hollows 4 No water at source or water level too low 5 Valve on suction lines closed b Pump Switches On and Off Frequently Cycling 1 Check that tank air charge is 130kPa 19 psi 2 Rapid cycl...

Страница 7: ...hot water in the pump to cool before attempting to dismantle During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING When servicing or attending pump always ensure power is switched off and lead unplugged Electrical connections should be serviced only by qualified persons WARNING Do not use hydrocarbon based or ...

Страница 8: ...igned or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorised persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the nameplate Your Davey Two Year Guarantee does not cover freig...

Отзывы: