Choosing a Site

Choose a site with a firm mounting position.  Allow room for removal of the lamp
and sleeve during servicing.  Leave a chamber lengths space at the lamp
connector end for lamp removal, with 100mm free at the other end for access to
the end nut.  The ‘open’ end nut and the blank end nut are interchangeable, so
lamp removal can be from either end.

Housing your Steriflo

®

System

To protect your Steriflo

®

system from the weather, make sure the site is water

proof, frost free and has adequate ventilation.  The unit should be either
horizontally mounted with the inlet and outlet facing upwards or vertically mounted
with the inlet at the bottom.  Allow for drainage, to avoid damage to flooring etc.,
that over time may occur from leaking pipe joints or seals and allow room to
remove the lamp.

WARNING: Some insects, such as small ants, find electrical
devices attractive for various reasons.  If your site or enclosure is
susceptible to insect infestation you should implement a suitable
pest control plan.

Содержание STERIFLO SF1000S mkII

Страница 1: ...should the UV Chamber be disassembled unless the internal pressure of the unit has been relieved Failure to observe this warning will expose persons to the possibility of personal injury and may resul...

Страница 2: ...Connection Page 5 Electrical Power Surge Protection Page 5 6 Pipe Connections Page 6 Pre treatment drinking water Page 6 Lamp Installation Page 7 Operation Page 7 Maintenance Page 8 9 Water Quality Pa...

Страница 3: ...with mounting brackets Before installing your new Steriflo please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Ultra...

Страница 4: ...Steriflo system from the weather make sure the site is water proof frost free and has adequate ventilation The unit should be either horizontally mounted with the inlet and outlet facing upwards or v...

Страница 5: ...or light mounted on its front panel adjacent to the amber power on LED This light will be illuminated whenever the Steriflo control box senses no lamp current There is also an audible alarm in the eve...

Страница 6: ...90o bends of a suitable material are connected to the inlet and outlet of the chamber Larger diameter pipe may be used to minimise resistance to flow but maximum flow rates should not be exceeded as c...

Страница 7: ...ansport tube touching the lamp as little as possible Handle the lamp by the ends where possible Wipe with clean cloth and methylated spirits if fingerprints or dirt need removing Slide the lamp into t...

Страница 8: ...it clean The sleeve should be cleaned every three months or as required Sleeve removal use care fragile 1 Remove lamp as described 2 Remove drain port cap and empty water from chamber 3 Undo nut at o...

Страница 9: ...und and the red LED will light and the alarm contacts will changeover These are able to close a normally open solenoid valve The alarm function can be checked by switching the unit off disconnecting t...

Страница 10: ...3N70 2 per sleeve d Lamp Connector All models S114 2 WARNING When servicing or attending your Steriflo always ensure power is switched off and lead unplugged Electrical connections should be serviced...

Страница 11: ...hours later Severe exposure sore red eyes sensitive to light painful to keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weep...

Страница 12: ...ustralian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising...

Отзывы: