Solarmatic Operating Instructions

1.  Once installation is complete and all connections have been made, 

turn the unit ON using the POWER button. The LED will illuminate 

green when it is on. 

2.  To set the temperature, use the DISPLAY MODE (

D

) button to 

select the SET function. Use the 

5

 

6

buttons

 

to enter your desired 

comfort temperature. Your setting will display briefly on the screen. 

NOTE:

 Once your swimming season is over we suggest you re-set 

the SET temperature to 10°C as this will prevent the solar heating 

system running unnecessarily in cold weather.

3.  Using the SOLAR PUMP button, select AUTO to run the system in 

automatic mode. 

Operating Notes

The ROOF Sensor

 

The ROOF temperature reading is a combination of heating by the sun and 

heating/cooling by the air/wind. It is essentially a reading that provides an 

estimate of the amount of warmth available to heat the pool. 
If the ‘daytime’ temperature is 25°C, the roof may vary from 25°C to 50°C. It is 

possible for the overnight and early morning ROOF temperature reading to go 

below 5

°

C. When this occurs the unit will register a false warning (

rr

) to check 

the ROOF sensor – wait for the day to warm up before taking any action.

ECO Mode

 

This feature will reduce unnecessary pump operation and therefore reduce 

operating costs. When this mode is ON, if the roof is not warm enough to 

bring the pool temperature up significantly the solar pump will not run, as 

the amount of heat to be collected is not worth the cost of the power used to 

run the pump. 
Without this feature ON a ROOF that is under 20

°

C will try to warm a pool 

that is 12

°

C, using electrical power for very little pool heating.

ECO Mode - ON

 

Your controller should start in Eco Mode.
This mode stops the operation of the solar pump when the roof temp is 

below 30

°

C or the roof is less than 6

°

C warmer than the pool. 

To turn ECO Mode 

ON

 press the SET TEMP 

5

 

6

 buttons at the same time.

Eco Mode - OFF 

With ECO Mode turned off,  the solar pump can run when the roof reading 

is just 20°C and the pool is only 2°C (or more warmer than the pool). 

If your pool has a thermal blanket this mode may be able to provide extra 

swimming time at an increased solar pump operation cost.
To turn ECO Mode 

OFF

 press the SET TEMP 

5

 

6

 buttons at the same time.

Содержание SolarMatic

Страница 1: ...Solar Pool Heating Controller Installation and Operating Instructions Please pass these instructions on to the operator of this equipment...

Страница 2: ...etre pool temperature cable with black connector and brass sensor 1 x 25 metre roof temperature cable with red connector and plastic sensor 1 x Blank flow connector 2 x Mounting Screws with wall plugs...

Страница 3: ...cement render can damage aluminium if in doubt seal the wall before mounting the control unit Drill pilot holes and fit screws provided 3 Mount unit via top moulding of the SolarMaticTM unit Slot in b...

Страница 4: ...er P N M6522 3 Fit blank flow connector to the socket marked FLOW Congratulations You are now the proud owner of the advanced SolarMatic Solar Pool Heating Controller SolarMatic extends your swimming...

Страница 5: ...re switch between pump and filter The pressure switch should be tapped into a point where the pipe enters a fitting to allow a good thread length Tap size is 1 8 NPT Take care not to damage threaded e...

Страница 6: ...d it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard 4 Instrument Panel Displays Feat e flow fault being rectified or wait for a ma...

Страница 7: ...es auto run and RED LED indicates manual run Tropical T Mode Press to Auto Tropical mode for over night cooling PUMP RUN LED Indicates solar pump is ON LED will be illuminated RED when In Auto Normal...

Страница 8: ...ng to go below 5 C When this occurs the unit will register a false warning rr to check the ROOF sensor wait for the day to warm up before taking any action ECO Mode This feature will reduce unnecessar...

Страница 9: ...e back on or the first solar pump operation to reset To reset this function simply turn the solar pump ON and OFF manually at approximately the time you would like the Auto Purge function to run the p...

Страница 10: ...tion Action No power to unit Mains power outlet switched OFF Turn ON SolarMatic not plugged into mains power outlet Connect plug SolarMatic controller not ON Press POWER Button ON Problem 4 Pool not h...

Страница 11: ...ur receipt as proof of purchase you MUST provide evidence of the date of original purchase when claiming under the Davey One Year Guarantee Davey shall not be liable for any loss of profits or any con...

Страница 12: ...12 MOUNTING TEMPLATE 18 mm...