background image

11

To operate a suction pool cleaner with your PowerMaster Eco Series 

pump:

1. Activate the High Flow setting and allow the pump to fully prime by 

running for around 2 minutes. You will know the pump is primed when 

you can see a strong flow of water through the clear leaf basket lid.

2. When all air is expelled from the leaf basket, connect the pool cleaner 

hose firmly into the skimmer plate or dedicated wall suction. 

3. Select the speed setting that enables best performance from your 

automatic pool cleaner. Mid setting should be ample for most cleaners 

but if the cleaner requires better performance, activate the High Flow 

setting. Eco Flow can be used to run a Davey Suction pool cleaner, but it 

is recommended that Mid Flow is used.

4. The cleaner should only be connected for as long as is required to clean 

the surface of your pool. When cleaning is complete, disconnect the 

cleaner and remove the skimmer plate from the skimmer box. 

NOTE:

 To get optimum energy efficiency from your PowerMaster

®

 

ECO pump 

DO NOT

 keep the automatic pool cleaner connected when 

cleaning is not required.

5. Reactivate the most efficient speed setting for daily filtration. The ECO 

Flow setting is recommended.

Maintenance:

Emptying the Strainer Basket

The strainer basket should be inspected frequently through the transparent 

lid and emptied when a build up of rubbish is evident. The directions below 

should be followed.
1. Switch off pump.
2. Unscrew the strainer basket lid anti-clockwise and remove.
3. Remove the strainer basket by lifting upwards from its housing.
4. Empty the trapped refuse from the basket. Hose out with water if necessary.

NEVER knock the plastic basket on a hard surface as it will cause damage.

5. Check the strainer basket for cracks, replace the strainer basket in the pump if OK.
6. Replace the lid and ensure that it seals on the large rubber o-ring. 

Firm 

hand tightness only is required.

 The o-ring & thread can be lubricated 

with Hydra slip or equivalent products.

Содержание PowerMaster Eco PMECO

Страница 1: ...perating Instructions WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage The installation of this product should b...

Страница 2: ...formance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performance that lasts and lasts Saving Energy with your Davey PowerMaster ECO Series Pump Th...

Страница 3: ...eed to the Eco speed The Mid speed is also programmable in 50rpm increments up to the High speed and down to the Eco speed This function is available to assist in those applications where greater than...

Страница 4: ...Flow 155W 0 2 hp Mid Flow 596W 0 8 hp Hi Flow 957W 1 3 hp Pump Output Power W hp Eco Flow 124W 0 2 hp Mid Flow 477W 0 6 hp Hi Flow 766W 1 0 hp Operating Limits Max Water temperature 50 C Max Ambient...

Страница 5: ...240 volt 50Hz power supply and are equipped with a flex and 3 pin plug If a power outlet is not available within 3 metres of the pump a 3 pin power point in a safe dry place may need to be provided b...

Страница 6: ...level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pipe from the filter to the pool The fittings on this product are constructed of ABS Some PVC...

Страница 7: ...mp outlet should be connected to the inlet connection on the swimming pool filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required...

Страница 8: ...ainer basket lid and filling the strainer basket area with water Replace the lid ensuring that it seals on the large o ring 2 Connect to the power supply and switch on 3 Allow the pump to run so that...

Страница 9: ...onal Davey or your Davey dealer Operation Recommended Speed Settings Pool Filtration ECO Flow Automatic pool cleaner operation Mid Flow Backwashing your media filter High Flow Manually cleaning your p...

Страница 10: ...nce for the flow in your pool and refer to the pressure indicated by the gauge on the filter Ensure flow rate is sufficient to cover cell plates completely at all times of operation 18 TOTAL HEAD m 2...

Страница 11: ...aner and remove the skimmer plate from the skimmer box NOTE To get optimum energy efficiency from your PowerMaster ECO pump DO NOT keep the automatic pool cleaner connected when cleaning is not requir...

Страница 12: ...and that the pool water level is up to the skimmer box 6 Blockage in the piping or pump Remove the strainer basket and check for any blockage to the pump impeller entry Check the skimmer box for block...

Страница 13: ...e 100 C Under temperature 20 C 4 Over current trip Over current protection has tripped 5 Mains over voltage The mains voltage has risen above 269 volts AC 6 Output shaft seized Motor failed to start M...

Страница 14: ...the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your PowerMaster be certain to quote the model number from the...

Страница 15: ...rs are securely attached and in safe working condition These should be replaced every 3 to 4 years d Remove any obstructions or debris from the main drain cover e Ensure the skimmer baskets and the pu...

Страница 16: ...ity The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during t...

Отзывы: