7.1 Battery:

This is not included, though battery leads are 

included. The battery required is a 12V lawn mower 

style battery, below are some acceptable options.

Length Width

Height 

(not including terminals)

Marshall PowerRider

196

128

184

Century EverRide

196

128

156

The black battery lead should be connected to the 

negative terminal (-ve) on the battery. Only once 

ready, including after all necessary external wiring 

connections are complete (refer section 7.8), should 

the red lead be connected to the positive terminal 

(+ve) on the battery.
During daily usage, the battery will be recharged. If 

you only intend to use the pump unit occasionally 

or in an emergency, you should add a trickle charge 

system to the battery.
For areas away from mains electricity this charger 

should be a solar powered unit.
A 40W trickle charger with solar control should be 

used as a minimum. The pump should still be run 

for an entire fuel tank every 3 weeks, to ensure the 

battery is kept fully charged and that petrol doesn’t 

go stale.

CAUTION: Ensure that the battery 

terminals are only connected to the 

correct battery leads and do not 

touch the battery retention brackets 

or any other part of the frame or 

pump unit. 

7.2 Aerial:

The aerial must be connected to the port on the side 

of the remote/auto controller.

7.3 Compliance:

This product is designed and tested to all applicable 

Australian standards including AS/CA S042.1:2015, 

AS/CA S042.4:2015, AS/NZS 2772.2:2011 and AS/

NZS CISPR 22:2009 + A1:2010.

7.4 RF Exposure:

Your device contains a transmitter and a receiver. 

When it is on, it receives and transmits RF energy. 

When you communicate with your device, the system 

handling your connection controls the power level at 

which your device transmits. This device is designed 

and manufactured not to exceed the emission limits 

for exposure to radio frequency (RF) energy set by 

the Australian Communications & Media Authority 

(refer to AS/NZS 2772.2:2011). To comply with limits 

this equipment should be installed and operated with 

minimum distance 20 cm between the radiator & your 

body. The supplied antenna ensures compliance with 

the required limits.

7.5 External Antenna:

Any external antenna used for this transmitter must 

be installed to provide a separation distance of at 

least 20 cm from all persons and must not be co-

located or operated in conjunction with any other 

antenna or transmitter. Please consult the health 

and safety guide of the chosen antenna for specific 

body separation guidelines as a greater distance of 

separation may be required for high-gain antennas.  

The maximum allowable antenna gain for this device 

in order to meet required limits when operated at 

least 20 cm from all persons is as below: -

WCDMA

20dBi

B1 (1922.5MHz)

18.1dBi

B3 (1784.3MHz)

16.3dBi

B5 (848.3MHz)

7.0dBi

B7 (2535MHz)

19.4dBi

B28 (746.5MHz)

6.2dBi

7.6 Rubber feet or mounts:

These are not fitted but included in the plastic bag 

containing this Installation and Operating Instructions. 

Fit these to the four corners of the carry frame 

through the holes provided.

7.7 Operation options:

Your Davey 5190HRS2 and 5290HRS2 pump unit is 

designed to allow for a variety of start and stopping 

options. These options are prioritised according to 

importance for protection, e.g. fire protection takes 

priority over tank filling etc.
Manual Control: This includes manual use of the key 

starter or recoil starter. This is the top level of control 

and allows you to manually start and stop the pump 

at any time, allowing for the following:
1) The key must be in the “on” position to allow for 

recoil starting.

2) The key must be turned to the “off” position to 

manually stop the pump

SMS start / stop:  A command to start or stop the 

pump will override all other sensor inputs.  Settings 

to stop the pump after a pre-set period or on a 

scheduled time setting (commands “timer”, “delay” 

or “sch” – SMS Control Commands) will not override 

Fire Sensor or Emergency Switch running.
Sensor Start or Sensor Start/Stop Options include 

fire sensors, emergency button, pressure switch 

shut down, float shut down or on/off switching. 

These sensors are connected via the appropriate 

terminal on the Remote/Auto Control Centre which 

is mounted on the pumpset carry frame.

Содержание Firefighter 5113HE

Страница 1: ...ine manufacturer s instructions on to the operator of this equipment Engine Driven Pumps Models 5148YEV 5150HD 5150P 5155H 5155H NPT 5155H3 5155HFRN 5155HV 5165H 5165HE 5165HQ 5170YE 5190HRS2 5113HE 5...

Страница 2: ...rk 5 3 2 Pump operation 6 3 3 Removal of impeller 6 3 4 Avoiding pump damage 6 3 5 Storage 6 3 6 Fuel petrol 6 3 7 Fuel diesel 6 3 8 Engine oil 7 3 9 Air cleaners 7 3 10 Engine cooling 7 3 11 General...

Страница 3: ...7 9 Engine speed and stopping 13 7 10 SMS control 13 7 11 Set up 13 7 12 Control commands 16 7 13 SMS feedback 17 7 14 Removal of impeller 17 8 TECHNICAL SPECIFICATIONS 18 8 1 Weights and dimensions...

Страница 4: ...e the air from itself and its suction line if it has nowhere for the air to go To help clear the air and properly prime the pump Make sure the Firefighter pump has an open discharge to atmosphere near...

Страница 5: ...back past the priming flap Before attempting to self prime the Firefighter pump you may need to check that the casing is still full of water ATTENTION In the event of fire damage to the Viton elastom...

Страница 6: ...ovals program 3 5 Storage IMPORTANT The Firefighter pump should be drained of water and normal engine storage procedure should be followed Run the engine until fuel is exhausted drain and fill sump wi...

Страница 7: ...rrounding heat and the more radiant heat the engine is exposed to the lower the performance The effects of radiant heat should not be underestimated Protect the engine from radiant heat Install the en...

Страница 8: ...cture Controlled via a key switch the solenoid starts and stops the flow of fuel to the engine to start and stop the Firefighter pump This allows the Firefighter pump to be installed on a tray back ve...

Страница 9: ...so it should not be attached to the Firefighter Attach it to the Roll Frame or similar For any further information or fitting advice please contact your nearest Authorised Honda Dealer 4 7 Remote sta...

Страница 10: ...ted IN EMERGENCY CIRCUMSTANCES ONLY OIL LEVEL CUT OUT MAY BE DISABLED AS FOLLOWS Disconnect yellow lead to starting switch at bullet junction IMPORTANT WARRANTY FROM THE ENGINE MANUFACTURER MAY BE JEO...

Страница 11: ...operated with minimum distance 20 cm between the radiator your body The supplied antenna ensures compliance with the required limits 7 5 External Antenna Any external antenna used for this transmitter...

Страница 12: ...closed within 4 minutes otherwise LOP fault Flow Pressure LOP Switch Input 3 GND 3 Once running if opens fault after 30 seconds Bridge if not used No Pre Bridge if not used Figure 7 4 60mm 60mm Figure...

Страница 13: ...ow Pressure LOP Switch is open and the 4 minutes initial start or 30 second once primed timer has elapsed the pump will shut down due to loss of prime closed head Normally open turn on when closed off...

Страница 14: ...sword simply click the Forgot your password link to reset Click on the REMOTE START FIREFIGHTER thumbnail Figure 7 13 Figure 7 13 Click REGISTER PUMP Figure 7 14 Figure 7 14 Activate the remote start...

Страница 15: ...r convenience the user can choose to enter credit card details straightaway allowing an automated credit card payment once due To make a payment or renew a subscription click the CARD symbol Figure 7...

Страница 16: ...or delay commands Timer hh mm Starts the pump and runs for X minutes up to 24 00 hrs E g If you SMS Timer 1 10 the pump will run for 1 hour 10 minutes Delay hh mm Timer hh mm Delays the starting of t...

Страница 17: ...a setscrew It can be disassembled in two halves by removing the setscrew This practice allows the impeller to be cleaned without disrupting the mechanical seal and potentially creating additional ser...

Страница 18: ...70N5 iGX270 GX390 Model 5248Y 5250P 5255H 5255H NPT 5265H 5265H NPT 5265H23W Weight kg 36 10 28 27 28 26 28 Inlet 1 BSP M 1 BSP M 1 BSP M 1 NPT M 1 BSP M 1 NPT M 2 BSP M Outlet 4 way 1 1 1 1 BSP M 4 w...

Страница 19: ...ller Three Way Discharge 5165H3 5165HQ Yanmar L70N Single Impeller Diesel Electric Start 5170Y 5170YE Honda GX160 Single Impeller NPT Three Way Discharge 5155H NPT Honda GX270 Single Impeller Electric...

Страница 20: ...ls fitted with L100N engines 1 13039 3MSPY 13 Casing Rear 3 4 yellow models fitted with L70N engines only 1 13039 2MSPY 13 Casing Rear yellow models fitted with GX270 and GX390 engines only 1 13039 1M...

Страница 21: ...T Three Way Discharge 5255H NPT Honda GX200 Twin Impeller NPT Three Way Discharge 5265H NPT Honda GX270 Twin Impeller NPT Remote Start 5290HRS2 NPT Honda GX270 Twin Impeller Electric Start Three Way D...

Страница 22: ...tage All other models not specified 1 13379 16 Impeller bottom 2nd stage Yanmar 5248Y 5270Y 5270YE only 1 13535 1SP 16 Impeller bottom 2nd stage 5290B 5290H only 1 13376 4SP 16 Impeller bottom 2nd sta...

Страница 23: ...ng kit Not Illustrated 1 32249 E Viton seal kit 5 8 seal 3 way outlet Not Illustrated 5265H HE only 1 32245 E Viton seal kit 33mm seal 3 way outlet Not Illustrated models fitted with GX270 GX390 engin...

Страница 24: ...normal wear and tear or apply to a product that has been subject to misuse neglect negligence damage or accident been used operated or maintained other than in accordance with Davey s instructions no...

Страница 25: ...roducts The repair of your products may result in the loss of any user generated data Please ensure that you have made a copy of any data saved on your products To the fullest extent permitted by law...

Страница 26: ...26 NOTES...

Страница 27: ...27...

Страница 28: ...view Drive Scoresby Australia 3179 Ph 1300 232 839 Fax 1300 369 119 Email sales davey com au daveywater com NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Email...

Отзывы: