background image

4

9

ECO-SPA

TM  

INSTALLATION INSTRUCTIONS

(Refer to diagram next page)

1.   

Please ensure the EcoSpa™ Control Unit is mounted a minimum of 3 metres 

away from the spa water and 1.5 metres above ground level. For a portable 

VSDWKH(FR6SDŒXQLWFDQEH¿WWHGRQWKHLQVLGHRIWKHVSDVXUURXQGSOHDVH

ensure easy access.    

2.     Select mounting point and mark 2 holes 18mm apart. (If the unit is to be 

mounted to a brick or concrete wall use a masonry drill bit. Some walls such 

DVOLPHVWRQHRUFHPHQWUHQGHUFDQGDPDJHDOXPLQLXPLILQGRXEWVHDOWKHZDOO

EHIRUHPRXQWLQJWKHFRQWUROXQLW'ULOOWKHKROHVDQG¿[VXLWDEOHVFUHZVWR

each hole. Recommended screws are 8 gauge.  

 +DQJXQLWYLDVORWVLQWKHWRSUHDUVHFWLRQRI(FR6SDŒXQLW1%7KHDGGLWLRQDO

mounting hole at the base of the EcoSpa™ can be used to help secure the unit.  

4.   

Plug power plug from control unit into a suitable weatherproof power outlet. 

(QVXUHDSSURSULDWH5&'VDIHW\GHYLFHLV¿WWHGWRPDLQVSRZHU'RQRWWXUQ

SRZHURQXQWLOLQVWDOODWLRQLVFRPSOHWH:KHQXVHGZLWKFRQWUROOHUSOXJLQWR

R]RQHSRVLWLRQDQGVHWGLSV ,WR

5.   

Install  Manifold for ORP Sensor Probe and Pressure Switch into spa return  

line after the pump.    

6.    Plumb Electrolytic Cell into spa return line injection housing. Plug Cell 

connector into the appropriate receptacle in the bottom of the unit. The Cell can 

be installed vertically or horizontally. NOTE: ORP Sensor and pressure switch 

0867EHLQVWDOOHGSULRUWRWKH&HOODQGDWOHDVWPP´IURPWKH&HOOLQOHW

preferably further away.

IMPORTANT NOTICE: 

For installations where manifold is not used, the pressure 

switch must be  installed  at  suitable  point  on  spa  return.    If  return  does  not  

KDYHHQRXJKSUHVVXUH¿WWKHSUHVVXUHVZLWFKEHWZHHQSXPSUHWXUQDQG¿OWHU

7KHSUHVVXUHVZLWFKVKRXOGEHWDSSHGLQWRDSRLQWZKHUHWKHSLSHHQWHUVD¿W-

ting to allow a good thread length. Tap size is 1/8” NPT. Take care not to damage 

threaded end and use thread tape for a good seal.

)LW2536HQVRU3UREHDWOHDVWPP´EHIRUH&HOO7R¿W2536HQVRU3UREH

drill hole and tap with a 1/4” BSPF tap. This must be done carefully to ensure a 

JRRGWKUHDGHG¿W6FUHZWKH2536HQVRU3UREHLQWRWKHSLSHZRUN1RWHWKDWLWLV

EHVWWR¿WWKH2536HQVRU3UREHLQWRD¿WWLQJHOERZFRXSOLQJHWFWRHQVXUHJRRG

thread length.  

7.     Connect the pressure switch to the EcoSpa™ Control Unit via the cable 

terminated in two insulated pade connectors. Note that the pressure switch is 

not waterproof and should not be exposed to the weather.

8.   Connect ORP Sensor Probe to socket under EcoSpa™ Control Unit.  

*  Installation and operating instructions are included with the product when purchased new. 

They may also be found on our website.

AUSTRALIA
Davey Support Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 367 866

Fax: 

1300 369 119

Website:  davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND
Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph:  

   0800 654 333

Fax:       09 527 7654

Website:  daveynz.co.nz

® Davey is a registered trademark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2012.

Davey

®

 Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction 
within warranty periods beginning from the date of original purchase due to faulty materials or 
manufacture, Davey will at our option repair or replace it for you free of charge, subject to the 
conditions below.

Davey Guarantee Period

    Control Box - Two Years 

Electrolytic Cell - Three Years       ORP Probe - Three Years

Should you experience any difficulties with your Davey product, we suggest in the first instance 
that you contact the Davey Dealer from which you purchased the Davey product. Alternatively 
you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New 
Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim, 
Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how 
to have your Davey product repaired, obtain a replacement or a refund.

Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product 
consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from 
misuse or negligent handling, improper use for which the product was not designed or advertised, 
failure to properly follow the provided installation and operating instructions, failure to carry out 
maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes, or 
unauthorized persons attempting repairs.  Where applicable, your Davey product must only be 
connected to the voltage shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. 
Please retain your receipt as proof of purchase; you 

MUST

 provide evidence of the date of original 

purchase when claiming under the Davey Guarantee. 

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, 
damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This 
limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee 
applicable to your Davey product under the Australian or New Zealand legislation and does not 
affect any rights or remedies that may be available to you under the Australian or New Zealand 
Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for 
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired 
or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major 
failure.

Should your Davey product require repair or service after the guarantee period; contact your 
nearest Davey Dealer or phone the Davey Support Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

Содержание EcoSpa M7000AMP

Страница 1: ...on knowledgable in spa pool plumbing requirements following the Installation Instructions provided in this manual WARNING Failure to follow these instructions and comply with all applicable codes may...

Страница 2: ...enance electrode enabling you to choose the level of sanitiser you desire and constantly monitoring and maintaining the level thereafter EcoSpa is compatible with OzoMatic Ozone Systems and is suitabl...

Страница 3: ...c housing located in the plumbing XULQJ WKH URPLQDWLRQ SURFHVV D ZKLWH SRZGHU DOFLXP VFDOH PD QDWXUDOO build up on the titanium plates in the cell Monitor the cell to prevent excessive scale build up...

Страница 4: ...pump 6 Plumb Electrolytic Cell into spa return line injection housing Plug Cell connector into the appropriate receptacle in the bottom of the unit The Cell can be installed vertically or horizontall...

Страница 5: ...anges will be affected E VSD XVH WKH PRUH WKH VSD LV XVHG WKH PRUH IUHTXHQWO WKH ZDWHU FKDQJHV will be required For installations with a Davey Spa Power Controller 7KH PDQLIROG VKRXOG EH ORFDWHG DIWHU...

Страница 6: ...LQFUHDVH WKH OWUDWLRQ WLPH RU IROORZ WKH WURXEOH shooting procedures KLOVW WKH SXPS LV RII WKHUH ZLOO EH QR RZ DQG WKH 5HG 1R ORZ ZLOO EH OLW 7KLV LV QRUPDO LQ WKLV VWDWH WKH 253 5HGR PD LQGLFDWH XQGH...

Страница 7: ...DLVH WKH S DGG 62 80 5 21 7 25 62 6 7RWDO ONDOLQLW VKRXOG QRW EH FRQIXVHG ZLWK S DOWKRXJK WKH WZR DUH FORVHO UHODWHG 7RWDO ONDOLQLW GHWHUPLQHV WKH VSHHG DQG HDVH RI S FKDQJH W LV PHDVXUHG LQ SSP WKH L...

Страница 8: ...Z 3LSH RU HOO LV SDUWLDOO EORFNHG GMXVW SUHVVXUH VZLWFK VHH DUURZV RQ VLGH RI SUHVVXUH VZLWFK lift lock at back 2 No display 0DLQ SRZHU RXWOHW VZLWFKHG RII RU OWHU SXPS QRW UXQQLQJ FR 6SD70 QRW SOXJJH...

Страница 9: ...ng from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry...