Davey EcoPure DEP2140 Скачать руководство пользователя страница 8

AUSTRALIA
Customer Service Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 232 839

Fax: 

1300 369 119

Email: [email protected]

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND
Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

0800 654 333

Fax: 

0800 654 334

Email: [email protected]

Website: daveynz.co.nz

® Davey is a registered trademark of Davey Water Products Pty Ltd.  © Davey Water Products Pty Ltd 2017.

Davey Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within 

warranty periods beginning from the date of original purchase due to faulty materials or manufacture, 

Davey will at our option repair or replace it for you free of charge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that you 

contact the Davey Dealer from which you purchased the Davey product. Alternatively you can phone 

our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a 

written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve 

your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product 

repaired, obtain a replacement or a refund.

Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product 

consumables (i.e. o-ring seals, springs, media or gaskets), loss or damage resulting from misuse or 

negligent handling, improper use for which the product was not designed or advertised, failure to 

properly follow the provided installation and operating instructions, failure to carry out maintenance, 

corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons 

attempting repairs.  Where applicable, your Davey product must only be connected to the voltage 

shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. Please 

retain your receipt as proof of purchase; you MUST provide evidence of the date of original purchase 

when claiming under the Davey Guarantee. 

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or 

injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not 

apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey 

product under the Australian or New Zealand legislation and does not affect any rights or remedies that 

may be available to you under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any 

other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced 

if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Should your Davey product require repair or service after the guarantee period; contact your nearest 

Davey Dealer or phone the Davey Support Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

Davey Guarantee Period

Tank - Ten Years 

Multiport Valve - Three Years  Labour and Other Components - One Year

P/N 402086-3

Содержание EcoPure DEP2140

Страница 1: ... installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual INSTALLATION AND OPERATING INSTRUCTIONS WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage ...

Страница 2: ...tion the filter tank and pump on a level concrete slab or similar base with minimum dimensions of 900mm x 600mm 3 x 2 Do not use sand to level the concrete slab as it may wash away and cause vibration and inefficient performance Allow sufficient space around the filter for routine maintenance and provide for adequate filter drainage and pump ventilation Place the pump in position on the slab and l...

Страница 3: ...er draining from the pool during maintenance FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER DAMAGE NOT COVERED BY THE GUARANTEE Pipe Connections Use Teflon tape on all male threads Piping should be independently supported and not impose heavy loads on the filter or pump Use 40mm or 50mm 11 2 or 2 pipe from the pump to the skimmer box return pipe for the multiport valve to the pool ...

Страница 4: ...R OPERATES UNDER HIGH PRESSURE Ensure all lids closures clamps are correctly secured before operating system Never adjust clamps or change valve settings with the system under pressure Relieve all pressure from system before working on filter Multiport Valve Control The flow of water through the filter is controlled by the multiport valve on the top of the filter tank The handle on top of the valv...

Страница 5: ... necessary to clean or backwash the filter see section on Backwashing the Filter Backwashing the Filter When the filter gauge reading is 40 50kPa above the clean filter gauge reading cleaning or backwashing is required To perform the backwash operation 1 Shut off the pump Be sure to disconnect any automatic Vacuum Cleaner 2 Shift the valve handle to BACKWASH 3 Start the pump and run until the wate...

Страница 6: ...ter backwashing Check for blocked or plugged lines which could restrict flow Large quantities of media returning to the pool One of the lower laterals may be damaged To correct this condition the media must be removed and the lateral replaced Pump is operating noisily Investigate for a possible air leak in the suction line blocked pipes or rubbish in the pump strainer basket Refer to pump manual I...

Страница 7: ...e working condition These should be replaced every 3 to 4 years d Remove any obstructions or debris from the main drain cover e Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are clean and that all wiring and electrical equipment is in ...

Страница 8: ...which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the nameplate Your Davey Guarantee ...