background image

3

8. POWER CONNECTION

In accordance with AS 3350.2.41 we 

are obliged to inform you that this 

pump is not to be used by children or 

infirm persons and must not be used 

as a toy by children.

The electrical connections and 

checks must be made by a 

qualified electrician and comply 

with applicable local standards.

NOTE:

1. Ensure motor is connected 

to power supply specified 

on nameplate.

2. Avoid long extension leads as 

they can cause substantial voltage 

drop and operating problems.

3. Although the Davey Dynaflo electric 

motor is specifically engineered 

to perform on a range of power 

supply voltages, malfunctions 

or failure caused by adverse 

voltage supply conditions are 

not covered under guarantee.

Single Phase

The single phase Models 6200, 6210 & 6220, 

are supplied with a 10 amp plug or a special 

15 amp  power plug which may only be used 

with the appropriate 10 or 15 amp 220/250V 

power outlet (15 amp power outlets are usually 

specially provided by an electrician).
Always ensure that the earth conductor in 

the lead is connected to a good earth.
The Dynaflo single phase pump motor is 

designed and manufactured by Davey specially 

for this particular pump. It has no switch gear 

as this motor is the P.S.C. type. The capacitor 

is located inside the capacitor cover.
The Davey single phase pump motor is fitted 

with an inbuilt automatic reset thermal overload. 

This overload is designed to protect the motor 

from an overloading condition. Constant stopping 

and starting of the motor by this overload would 

indicate a problem to be rectified before use: 

e.g.  low voltage at pump (below 216 volts), 

excessive ambient temperatures (above 45°C).

WARNING: Automatic reset thermal 

overloads will allow the pump to restart 

without warning. Always disconnect 

the pump motor from the electrical 

supply before maintenance or repairs. 

The single phase Dynaflo 6220 may 

also be wired to a nominal 480V power 

supply, but must be reconnected at 

the terminals under the motor end 

cap/terminal cover, and wire in with 

a contactor. In addition, the overload 

fitted to the pump is only suitable for 

220/250V, and must be exchanged for 

the 480V overload supplied.
480V OVERLOAD (where applicable)

This 240/480V single phase motor is 

factory connected for use on nominal 

240V AC power supply. When the 

units are to be reconnected to suit a 

nominal 480V supply, overload P/No. 

48154 must be fitted into the motor 

endshield in place of standard overload. 

Reconnection for 480V must be carried 

out by an authorised electrician as per 

wiring diagram.

Three Phase

Three phase models are designed for connection 

to a nominal 415V power supply, but must be wired 

with a contactor with ‘quicktrip’ overloads set at 5.2 

amps for Model 6220, and 7 amps for Model 6230.

Davey recommend the use of overloads which 

also have the ability to detect  “single phasing” or 

“dropped phase” conditions in the power supply.

Three phase Dynaflo models have been designed 

to allow for connection either side of the Capacitor 

Cover (marked “A” in figure one) on the motor. 

(NOTE: Three phase motors do not have  

capacitors fitted in the Capacitor Cover).

This is achieved by way of either of the two 

19mm access holes (marked “B” in figure one).

The access holes are designed to accept most 

standard cable grommets. The unused hole can 

be sealed by inserting the plug enclosed with the 

pump.  To connect a three phase Dynaflo pump 

start by removing the Terminal Cover (“C”).