*NOTE: For protection, the Davey pump motor is fitted with an automatic
reset thermal overload, constant tripping of this overload indicates a
problem e.g. low voltage at pump, excessive temperature (above 50°C) in
pump enclosure.
IMPORTANT: DO NOT USE petroleum based fluids or solvents (e.g. Oils,
Kerosene, Turpentine, Thinners, etc) on the plastic pump components or
seal components.
ATTENTION: Care should also be taken when servicing or disassembling
pump to avoid possible injury from hot pressurised water. Unplug pump,
relieve pressure by opening a tap on the discharge side of the pump and
allow any hot water in the pump to cool before attempting to dismantle.
Maximum head pressure of the Davey CY Series is 36m.
WARNING: Automatic reset thermal overloads will allow the pump to restart
without warning. Always disconnect the pump motor from the electrical
supply before maintenance or repairs.
WARNING: Do not use hydrocarbon based or hydrocarbon propelled
sprays around the electrical components of this pump.
WARNING: When servicing or attending pump, always ensure power is
switched off and lead unplugged. Electrical connections should be serviced
only by qualified persons.
Trouble Shooting Check List
MOTOR OPERATING BUT NOT PUMPING:
1. Suction line and pump body not filled with water.
2. Leaking foot valve.
3. Air leaks in suction lines or suction pipe not under water.
4. Air trapped in suction lines (also possible with flooded suction)
due to uneven rise in piping (eliminate humps and hollows).
5. No water at source or water level too low.
6. Valve on suction or delivery lines closed.
MOTOR NOT RUNNING:
1. Power not connected.
2. Supply voltage too low.
3. Overload tripped.
4. Motor not free to turn e.g. a blocked impeller.
5. Internal motor fault.
After Sales Service
For professional after sales service or repair, contact your Davey Dealer.