6. Trouble Shooting

Error 

Reasons

How to solve it

CAL Err

If this error is displayed 
during the calibration 
phase and cycle it is as 
a result of:
1). Your pH probe is not 
working properly
2). Your buffer solution 

is polluted

3.) You have water/

oxidisation in the 
probe connector

1). Change the probe 

2). Change the buffer 

solution

3). Change over the 

probe

Alarm Alr Err

If the pH is lower than 
pH 5 or above pH 9, this 
alarm will be displayed 
and dosing will be 
stopped.

Adjust your water 
parameter manually so 
that it comes back to the 
required value of these 
parameters:

- Total alkalinity
- TH (hardness)
- pH

The dosing pump will 
restart as soon as the 
pH reading

If trouble persists, please contact Davey or your nearest Davey 
Dealer for assistance.

Содержание AS Series

Страница 1: ...e serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installation instruc...

Страница 2: ...lamp 9 3 2 3 Mounting of Injection Valve 9 3 2 4 Mounting of the Probe on the Probe Holder 10 3 2 5 Mounting description of Tube on the Injection Valve 10 4 Commissioning and Operation 11 4 1 Calibrat...

Страница 3: ...se for which it has been expressly designed namely the dosing of liquids Any different use is to be considered dangerous The pump should not therefore be used for applications that were not allowed fo...

Страница 4: ...power supply Before carrying out any service on the pump 1 Disconnect the mains power from the unit and 2 Relieve all the pressure from the pump head or the injection tube In the event of possible los...

Страница 5: ...duct needed to maintain the balance of the pool water 2 1 Parts description Here are the complete contents of the package you received All parts will be necessary for the proper operation of your devi...

Страница 6: ...set point 2 Press CAL allows calibration of the pH level associated to the SET button to change the value of the set point 3 Value level of pH in water 4 pH unit of measure to determine pool water ch...

Страница 7: ...f 200mm between the probe C and the injection valve E The injection valve E must be placed last in the pipework hydraulic installation In the case of an installation with redox and pH regulation it is...

Страница 8: ...the pump Remove the bracket on the pump by sliding it down Locate the bracket in the space chosen and mark the holes Drill the holes as required 3mm for timber walls 6mm for masonry walls Fix the bra...

Страница 9: ...ng of Injection Valve Fig 5 Fig 7 Fig 6 Fig 8 Oring A nut Put Teflon tape on threads Next Pierce the top wall of the pipe work through the clamp 8mm for the injection valve 14 mm for the electrode pH...

Страница 10: ...the probe has been constructed as indicated in Fig 9 tighten the probe nut without crimping the probe body Push the probe approximately 20mm into the pipe work so that the probe tip is approximately h...

Страница 11: ...t for reuse at the time of winterising 2 Rinse the probe in tap water for at least 20 minutes Steps Before carrying out the calibration of the probe remember to Stop the filtration pump Close the isol...

Страница 12: ...leted It is now ready to measure the pH of your pool 3 Next immerse the probe in the pH 7 solution stir around in bottle and leave it in the solution being careful not to touch the probe or the cable...

Страница 13: ...ational time period proportional to the required dosage demand That is why the device often has the pump off This is normal Adjust the pH slowly to preserve the natural quality of your water After 30...

Страница 14: ...5 3 Controller Wintering Only in areas where subzero temperatures are experienced During winterising you must protect the peristaltic tube It is advisable to remove the peristaltic tube and flush it...

Страница 15: ...nnector 1 Change the probe 2 Change the buffer solution 3 Change over the probe Alarm Alr Err If the pH is lower than pH 5 or above pH 9 this alarm will be displayed and dosing will be stopped Adjust...

Страница 16: ...m misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out ma...

Отзывы: